Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

DUNGS MPA 41xx V2.0 - Automatic Burner Controls
DungsBurner control

DUNGS MPA 41xx V2.0 - Automatic Burner Controls

DUNGS MPA 41xx V2.0 adalah kontrol pembakar otomatis yang dirancang untuk mengelola proses pengapian, pemantauan nyala api, dan pengamanan pada sistem pembakaran industri. Produk ini tersedia dalam varian MPA 411x PF…

SKU 3G-OTH-02883

Juga terdaftar sebagai: MPA41XXV20 · MPA 41XX V2 0

Merek
Dungs
Item
MPA 41xx V2.0 - Automatic Burner Controls
Kategori
Burner control
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Konten Lembar Data

[{"filename":"3G-OTH-02883-pulse-firing_product-handbook_en_301459.pdf","text":"Manual\n MPA 41xx PF V2.0\n\n\n\n\n Edition: 2023.07\n\n\n\n\n Printed in Germany • Edition 2023.07 • Nr. 301459\n\n\n\n\n1 … 138\n No. 301 459 - GB\n\fTable of contents\n\n\nTarget group / warnings. ..........................................................................................................................................3\nIntended use, risks in case of misuse. ...................................................................................................................4\nApproval overview. ...................................................................................................................................................5\nSystem description / variants / accessories..........................................................................................................6\nTechnical data. ..........................................................................................................................................................7\nConnection diagram............................................................................................................................................. 8-9\nTechnical data for outputs / inputs. ................................................................................................................ 10-12\nFlame monitoring / connection of flame detector device............................................................................. 13-14\nInstallation of MPA 411x PF. ..................................................................................................................................15\nDimensions MPA 411x PF. .....................................................................................................................................16\nInstallation of MPA 412x PF. ..................................................................................................................................17\nDimensions MPA 412x PF. .....................................................................................................................................17\nDisplay AM 41..........................................................................................................................................................18\nDescription of functions\nUnlock function\nEnhanced unlock\nAccess level.............................................................................................................................................................19\nDescription of functions\nGas valves\nMultifunction inputs\nParameter mode\nAutomatic / parameter mode function switch......................................................................................................20\nFlow diagram..................................................................................................................................................... 21-25\nConfiguration of multifunction inputs / function outputs............................................................................. 26-27\nState description............................................................................................................................................... 28-33\nParameters / parameter changes..........................................................................................................................34\nParameters / description of parameters......................................................................................................... 35-49\nParameters / factory settings. ......................................................................................................................... 50-52\nStatus information. ........................................................................................................................................... 53-54\nMPA 4114 / version without display. ............................................................................................................... 55-56\nMPA 41x2 / version with display............................................................................................................................57\nMPA 41x2 / overview of display modes. ...............................................................................................................58\nMPA 41x2 / display..................................................................................................................................................59\nMPA 41x2 / operating display. ...............................................................................................................................60\nMPA 41x2 / operating display additional information / setting bus address....................................................61\nMPA 41x2 / information display....................................................................................................................... 62-63\nMPA 41x2 / error display. .......................................................................................................................................64\nMPA 41x2 / error memory display. ........................................................................................................................65\nMPA 41x2 / parameter display. ........................................................................................................................ 66-72\nMPA 41x2 / reset display. ................................................................................................................................. 73-74\nMPA 41x2 / shutdown function..............................................................................................................................75\nMPA 41xx errors without error ID..........................................................................................................................76\nMPA 41xx errors from the basic system......................................................................................................... 77-78\nMPA 41xx errors from the extension function................................................................................................ 79-81\nEMC-compliant version..........................................................................................................................................82\nSetting of field bus address, bus termination......................................................................................................83\nProfibus, Modbus, shutter control MPA 41xx EM 2/4.................................................................................... 84-99\nExtension module MPA 41xx EM 2/6........................................................................................................... 100-118\nFlame detector device.................................................................................................................................. 119-120\nUV 41 (HE). .................................................................................................................................................... 121-122\nUV 42 . .......................................................................................................................................................... 123-124\nFLW 20xx UV.................................................................................................................................................. 125-127\n\n\n\n\n Printed in Germany • Edition 2023.07 • Nr. 301459\nFLW 10xx IR................................................................................................................................................... 128-130\nFLW 41 I ......................................................................................................................................................... 131-132\nIgnition transformers.................................................................................................................................... 133-135\nVisionBox.............................................................................................................................................................. 136\n\n\n\n\n 2 … 138\n\f Product manual\n\n MPA 41xx PF V2.0\n\n\n Target group\n\n The target group for this manual is specialised gas\n safety and control technology personnel, qualified\n persons or the persons instructed by them.\n They can assess the work assigned to them as well as\n potential hazards on the basis of their technical training,\n knowledge and experiences, as well as knowledge of the\n relevant regulations. Only they are permitted to install, Place this user manual in an easily viewable\n start up, adjust and service the equipment in compliance location in the installation room! Perform work\n with the accepted rules of industrial safety. only after reading the safety instructions in\n this user manual.\n\n\n\n\n Warnings\n General warnings\n\n\n The accepted rules of industrial safety Protection must be ensured against\n and the accident prevention regula- environmental and climatic influences\n tions must be followed, taking safety (corrosion, snow, icing, moisture\n measures to ensure the protection (e.g. due to condensation), mould,\n of persons if necessary. UV radiation, harmful insects and\n toxic, corrosive solutions / liquids\n Set all settings and setting values only (e.g. cutting / cooling fluids)). Appro-\n in accordance with the user manual priate safety measures must be taken\n for the connected machine. depending on the installation location.\n\n\n\n Never perform work when gas pres- The device may…

Dokumen Teknis

Tidak ada dokumen teknis yang tersedia untuk produk ini.
Minta dokumentasi
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

Dungs Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

DUNGS MPA 41xx V2.0 adalah kontrol pembakar otomatis yang dirancang untuk mengelola proses pengapian, pemantauan nyala api, dan pengamanan pada sistem pembakaran industri. Produk ini tersedia dalam varian MPA 411x PF dan MPA 412x PF, dengan spesifikasi teknis yang mencakup tegangan suplai, konsumsi daya, dan suhu lingkungan sesuai data pabrikan. Sebagai komponen penting dalam peralatan pembakaran, DUNGS MPA 41xx V2.0 memastikan operasi yang andal dan aman pada ketel uap dan pembakar industri.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Apa fungsi DUNGS MPA 41xx V2.0?

DUNGS MPA 41xx V2.0 berfungsi sebagai kontrol pembakar otomatis yang mengelola urutan pengapian, memantau nyala api, dan memberikan pengamanan pada sistem pembakaran. Produk ini memastikan operasi yang aman dan andal pada ketel uap dan pembakar industri.

Apa spesifikasi teknis DUNGS MPA 41xx V2.0?

Spesifikasi teknis DUNGS MPA 41xx V2.0 mencakup tegangan suplai, konsumsi daya, dan suhu lingkungan sesuai data pabrikan. Varian yang tersedia adalah MPA 411x PF dan MPA 412x PF. Detail lengkap dapat dilihat pada lembar data teknis resmi.

Di mana beli DUNGS MPA 41xx V2.0 di Indonesia?

Anda dapat membeli DUNGS MPA 41xx V2.0 melalui 3G Electric, distributor resmi yang memasok dan mengirimkan produk ini ke Indonesia. Kami menangani logistik dan bea cukai untuk memastikan pengiriman tepat waktu ke lokasi Anda.

Bagaimana cara memasang DUNGS MPA 41xx V2.0?

Pemasangan DUNGS MPA 41xx V2.0 harus mengikuti petunjuk dalam manual pabrikan, termasuk diagram koneksi dan dimensi untuk varian MPA 411x PF dan MPA 412x PF. Pastikan pemasangan dilakukan oleh teknisi berpengalaman sesuai standar keselamatan.

Digunakan dalam

Aplikasi umum untuk Dungs
Industrial steam boilers — MB-ZRDLE MultiBloc on modulating gas-fired plant
Hospital and hotel plant rooms — MB-D series for two-stage commercial burners
Food-industry ovens and dryers — DMV butterfly valves on high-turndown modulating lines
Petrochemical gas-train skid assemblies — FRS / FRSBV regulators with GW pressure switches
Retrofit drop-in replacements for older Dungs MB assemblies on existing Weishaupt / Riello burners

Dungs Produk

3G Electric memasok Dungs burner control. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Rangkaian Gas & Katup Gas Transformator Pengapian Kontrol Pembakar Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
Base for MA 40-50-55
Pactrol
Base for MA 40-50-55
D-Series 70D40 and 70D41 Burner Control. Plug-in Amplifier Modules permit the selection of ultraviolet, repetitive self-check ultra-violet, AUTOCHECK infrared, or rectification methods of flame detection. The control system includes a safe start check, effective on each start. If the flame signal (real or simulated) is detected, the unit cannot be started
Fireye
D-Series 70D40 and 70D41 Burner Control. Plug-in Amplifier Modules permit the selection of ultraviolet, repetitive self-check ultra-violet, AUTOCHECK infrared, or rectification methods of flame detection. The control system includes a safe start check, effective on each start. If the flame signal (real or simulated) is detected, the unit cannot be started
Satronic
Satronic
Base DGAI
Base for MA 20
Pactrol
Base for MA 20
Satronic
Satronic
Relay DMG 972-N MOD.01
Satronic
Satronic
Relay DMG 972-N MOD.03

Lainnya dari Dungs

Lihat semua Dungs suku cadang
Dungs
Dungs
DUNGS FLW 2x UV - UV-Flame Sensors
Dungs
Dungs
DUNGS FLW 1x IR - IR-Flame Sensors