FBR FNDP 100/2 TC SI

Pembakar industri heavy oil dua tahap (two stages) FBR FNDP 100/2 TC SI dirancang untuk bahan bakar minyak berat kental (dense heavy oil) hingga 20°E pada 50°C. Dengan daya termal 798–1744 kW, laju aliran 70–150…

SKU 3G-FBR-00275

Merek
FBR
Item
FNDP 100/2 TC SI
Kategori
Burners & Combustion
UNSPSC
40101834 — Burners
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Distributor Resmi
Langsung dari OEM
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

FBR
Weight
136 kg
stage
2 stages
fuel type
Heavy oil
nozzle mm
235
fan motor w
4
power kw max
1744
power kw min
798
flow kg h max
150
flow kg h min
70
ip protection
IP 40
noisiness dba
/
pump motor kw
0.55
electrical supply
3
power supply info
3/N~400V,
current absorption a
4.35
thermal power mcal h
687-1500
nominal electric power w
14
max combustion air temp c
60

Konten Lembar Data

HEAVY-OIL BURNERS TWO STAGES SK072066_B_en HEAVY-OIL฀BURNERS฀TWO฀STAGES FNDP฀100/2฀-฀FNDP฀125/2฀-฀FNDP฀150/2 Burners฀for฀heavy-oil฀two฀stages. Available฀in฀two฀versions: -FNP฀for฀fluid฀heavy฀oil฀up฀to฀3,5°E฀at฀50°C -FNDP฀for฀dense฀heavy฀oil฀up฀to฀20°E฀at฀50°C They฀are฀composed฀by:฀fan฀at฀high฀pressurisation,฀combustion฀head฀with฀adjustment฀at฀high฀efficiency฀and฀high฀flame฀ stability฀and฀hydraulic฀system฀of฀regulation฀combustive฀air฀on฀the฀two฀stages฀of฀flame. Compact฀overall฀dimensions฀and฀disposition฀rationalized฀of฀the฀components฀with฀accessibility฀facilitated฀for฀the฀ operations฀of฀setting฀and฀maintenance. Complete฀of฀nozzles,฀flexible฀pipes฀and฀line฀filter฀(for฀the฀models฀FNDP฀the฀line฀filter฀is฀electrically฀heated฀and฀ equipped฀with฀a฀thermostat). Complete฀of฀flange฀and฀gasket฀for฀installation฀on฀generator. FNDP฀100/2฀-฀FNDP฀125/2฀-฀FNDP฀150/2 HEAVY-OIL BURNERS TWO STAGES SK072066_B_en TECHNICAL฀DATA฀FNDP฀100/2฀-฀FNDP฀125/2฀-฀FNDP฀150/2 MODEL FNDP฀100/2 FNDP฀125/2 FNDP฀150/2 Flow min. - max. * [kg/h] 40-100 60-125 70-150 Thermal power min. - max. * [Mcal/h] 392-980 588-1225 687-1500 Thermal power min. - max. * [kW] 456-1139 684-1424 798-1744 Fuel: HEAVY-OIL MAX 20°E at 50°C Intermitted working operation (min. 1 stop every 24 hours) two stages Environmental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max. temperature combustion air [°C] 60 Fan motor [kW] 2.2 3 4 Resistances [kW] 9 11 12 Power supply: 3/N~400V,฀1N~230V฀-฀50Hz Electric protection degree: IP฀40 Burner weight [kg] 100 130 136 *฀Reference฀conditions:฀Environment฀temperature฀20°C฀-฀Barometric฀pressure฀1013฀mbars฀-฀Altitude฀0฀metre฀(sea฀level). OPERATING฀RANGE฀DIAGRAM [mbar] 13 11 9 7 5 3 1 FNDP 100/2 FNDP 125/2 FNDP 150/2 -1 0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 [kW] Fig. 1 X = Thermal power Y = Pression in the combustion chamber The firing rates has been obtained based on test boilers in accordance with EN267 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non-compliance, contact the manufacturer. FNDP฀100/2฀-฀FNDP฀125/2฀-฀FNDP฀150/2 HEAVY-OIL BURNERS TWO STAGES SK072066_B_en DIMENSIONS [MM] Fig. 2 Dimensions฀FNDP฀100/2฀-฀FNDP฀125/2฀-฀FNDP฀150/2 MODEL A A max. B C D ØE TC TL I ØL M N FNDP฀100/2 656 1085 440 410 400 175 235 335 368 340 M12 190 FNDP฀125/2 820 1400 520 420 400 209 200 400 368 340 M14 230 FNDP฀150/2 820 1400 520 420 400 209 200 400 368 340 M14 230 FNDP฀100/2฀-฀FNDP฀125/2฀-฀FNDP฀150/2 HEAVY-OIL BURNERS TWO STAGES SK072066_B_en PRODUCT SPECIFICATION SHORT DESCRIPTION Light-oil burners two stages available in two versions: FNP for fluid heavy oil up to 3,5°E at 50°C or FNDP for dense heavy oil up tol 20°E at 50°C. DETAILED SPECIFICATION Light-oil burner two stages available in two versions: FNP for fluid heavy oil up to 3,5°E at 50°C or FNDP for dense heavy oil up tol 20°E at 50°C composed by: • Fan฀at฀high฀pressurisation; • Combustion฀head฀with฀adjustment฀at฀high฀performance฀and฀elevated฀flame฀stability; • Flange฀and฀insulating฀gasket฀for฀fixing฀at฀boiler; • Three-phase฀with฀neutral฀power฀supply; • Photodiode฀for฀flame฀detection; • IP฀40฀electric฀protection฀level; • Supports฀and฀tierods฀for฀burner฀extraction; • Easy฀extraction฀of฀combustion฀head฀without฀get฀off฀the฀burners฀by฀bolier. CONFORMING TO: • CE rules; • 2014/30/UE Directive E.M.C.; • 2014/35/UE Directive L.V.; • 2006/42/CE - 2006/42/EG - 2006/42/EC Directive MAC; • 2014/68/EU (art.4, par.3) Directive P.E.D.; • Reference rules: EN267 (liquid fuel) - EN746-2 (industrial thermoprocessing equipment). STANDARD EQUIPMENT • Flexible฀hoses฀for฀connection; • Line฀filter฀ (for฀the฀models฀FNDP฀the฀line฀filter฀is฀electrically฀heated฀and฀equipped฀with฀a฀thermostat); • Isomart฀gasket; • Nozzles; • Flange฀with฀insulating฀gasket; • Burner฀nameplate; • Warranty; • Instruction฀handbook฀for฀installation,฀use฀and฀maintenance. OPTIONAL • Noise฀protection. The฀illustrations฀and฀data฀here฀shown฀are฀indicative.฀F.B.R.฀Bruciatori฀S.r.l.฀reserves฀the฀right฀to฀bring,฀without฀any฀obligation฀of฀warning,฀any฀changes฀that฀would฀be฀appropriate฀to฀the฀continuing฀development฀of฀their฀products. FNDP฀100/2฀-฀FNDP฀125/2฀-฀FNDP฀150/2
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

FBR Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

Pembakar industri heavy oil dua tahap (two stages) FBR FNDP 100/2 TC SI dirancang untuk bahan bakar minyak berat kental (dense heavy oil) hingga 20°E pada 50°C. Dengan daya termal 798–1744 kW, laju aliran 70–150 kg/jam, dan motor kipas 4 kW, unit ini cocok untuk aplikasi ketel uap industri berskala besar. Dilengkapi nozzle 235 mm, sistem hidrolik pengaturan udara pembakaran, serta filter saluran berpemanas listrik dengan termostat, pembakar ini menawarkan stabilitas nyala api tinggi dan perawatan mudah.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Apa spesifikasi teknis FBR FNDP 100/2 TC SI?

Pembakar heavy oil dua tahap ini memiliki daya termal 798–1744 kW, laju aliran 70–150 kg/jam, motor kipas 4 kW, dan motor pompa 0,55 kW. Suplai listrik 3/N~400V, 50 Hz, proteksi IP 40, dan berat 136 kg. Cocok untuk minyak berat kental hingga 20°E pada 50°C.

Untuk apa FBR FNDP 100/2 TC SI digunakan?

Pembakar ini digunakan pada ketel uap industri (boiler) untuk menghasilkan panas dengan bahan bakar heavy oil. Sistem dua tahap memungkinkan pengaturan daya secara bertahap, cocok untuk aplikasi pabrik kelapa sawit, semen, atau industri pengolahan lainnya yang membutuhkan pembakaran minyak berat.

Apa perbedaan FNP dan FNDP pada seri FBR ini?

FNP dirancang untuk heavy oil cair (fluid) hingga 3,5°E pada 50°C, sedangkan FNDP untuk heavy oil kental (dense) hingga 20°E pada 50°C. FNDP 100/2 TC SI termasuk varian FNDP, sehingga cocok untuk minyak berat dengan viskositas lebih tinggi.

Di mana beli FBR FNDP 100/2 TC SI di Indonesia?

Anda dapat membeli FBR FNDP 100/2 TC SI melalui 3G Electric, distributor resmi yang memasok dan mengirimkan peralatan industri ini ke seluruh Indonesia. Kami menangani logistik dan bea cukai untuk memastikan produk sampai ke lokasi Anda.

Bagaimana cara memilih pembakar heavy oil yang tepat?

Pertimbangkan daya termal yang dibutuhkan (FNDP 100/2 TC SI: 798–1744 kW), jenis bahan bakar (heavy oil hingga 20°E pada 50°C), dan sistem pengapian dua tahap. Pastikan juga suplai listrik 3/N~400V dan suhu udara pembakaran maksimal 60°C sesuai spesifikasi.

Digunakan dalam

Aplikasi umum untuk FBR
Hospitality and commercial HVAC — cast-iron boiler plants in hotels and shopping complexes
Pharmaceutical and biotech process heat — gas-fired burners with ATEX gas trains for classified-zone requirements
Medical-waste and bio-hazard incineration — FGP progressive dual-fuel systems
Food and beverage steam boilers — single-stage G-series for continuous-duty cycles
Marine and offshore platforms — IP54-rated X-series for high-humidity marine operations

FBR Produk

3G Electric memasok FBR burners & combustion. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Rangkaian Gas & Katup Gas Transformator Pengapian Kontrol Pembakar Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
FNDP 100/2 TL SI
FBR
FNDP 100/2 TL SI
FNDP 70/2 TC SI
FBR
FNDP 70/2 TC SI
FNDP 45/2 TC SI
FBR
FNDP 45/2 TC SI
FNDP 25/2 TC SI
FBR
FNDP 25/2 TC SI
FNDP 100/M TC SA
FBR
FNDP 100/M TC SA
FNDP 70/2 TL SI
FBR
FNDP 70/2 TL SI

Lainnya dari FBR

Lihat semua FBR suku cadang
FNDP 100/2 TC
FBR
FNDP 100/2 TC
FBR
FBR
FNDP 750/M TL MEC
FBR
FBR
FNDP 250/M TL MEC
FBR
FBR
FNDP 450/M TL MEC
FBR
FBR
FNDP 350/M TL MEC
FBR
FBR
FNDP 150/M TL
FNDP 125/2 TC
FBR
FNDP 125/2 TC
FBR
FBR
FNDP 190/M TL MEC