Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

FBR variant_2 - Burners & Combustion
FBRBurners & Combustion

FBR variant_2

Pembakar industri FBR K 4/M/2 EL EVO2 adalah unit dual fuel gas/light-oil yang dilengkapi dengan electronic control box untuk pengoperasian 2 tahap sliding atau modulating. Dengan daya termal 100/200-450 Mcal/h dan…

SKU 3G-FBR-00172

Juga terdaftar sebagai: 00430551 · 004305 51 · 004305-51

Merek
FBR
Item
variant_2
Kategori
Burners & Combustion
UNSPSC
40101834 — Burners
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Distributor Resmi
Langsung dari OEM
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

FBR
Weight
11 kg
stage
2 stages sliding or modulating
fuel type
Dual fuel gas/light oil
nozzle mm
250
fan motor w
2.2
power kw max
523
power kw min
116
ip protection
IP40
noisiness dba
82-83
pump motor kw
750
gas consumption
11.7/23.4-52.6
electrical supply
3
power supply info
3~400V, 1N~230V
current absorption a
6.8
thermal power mcal h
100/200-450
nominal electric power w
3.5
max combustion air temp c
60

Konten Lembar Data

DUAL FUEL GAS/LIGHT-OIL BURNERS WITH SK073551_A_en ELECTRONIC CONTROL BOX K 4/M/2 EL EVO2 Dual fuel gas/light-oil burners with electronic control box. Gas fuel operation: two stages progressive or modulating operation (if equipped with addition of optional modulation kit PID and probe; to guarantee an ideal proportionality of the power supplied to the thermal load). Light-oil fuel operation: two stages. Composed by: aluminium frame, fan at high pressurisation and combustion head with adjustment at high efficiency and high flame stability. Compact overall dimensions and disposition rationalized of the components with accessibility facilitated for the operations of setting and maintenance. Available in the versions METHANE (natural gas) or L.P.G. (to specify at the order) on demand specific versions for town gas, coal gas or biogas. Gas train complete with: work valve with adjustment, safety valve, minimum gas pressure switch and filter. Complete of: flange and gasket for installation on generator, nozzles, flexible pipes and line filter. The servomotors are indipendent and managed directly from the electronic control box of the burner: one servomotor for the gas modulator and one servomotor for the air shutter. The burners are equipped with a display that allows to: - adjust the operating parameters of the burner - visualize the flame intensity - adjust the operating curve of the burner (air / gas ratio) With the addition of optional accessories (probes) thanks to the most advanced systems for automatic modulation in mechanical or electronic version, the burner constantly ensures the proper gas / air ratio. The maximum efficiency of the returns in each combustion point derived from the punctual adaptation of the thermal load to the heat requirements of the burner at any instant of operation. In the version with the electronic cam the fuel / combustion air curve, more extended, is fully exploited, guaranteeing excellent performance in terms of accuracy and speed, even during the calibration phase. A microprocessor monitors the different stages of the process and allows the correct repetition of the sequences of operation. Optional accessories: PID power modulator kit, probe, PC interface, VSD, O2 control, O2 + CO control, field bus (profibus, modbus, profinet). Fig. K 4/M/2 EL EVO2 K 4/M/2-EL EVO2 DUAL FUEL GAS/LIGHT-OIL BURNERS WITH SK073551_A_en ELECTRONIC CONTROL BOX CONTROL BOX LAMTEC BT3 Fig. Control box Lamtec BT3 K 4/M/2-EL EVO2 DUAL FUEL GAS/LIGHT-OIL BURNERS WITH SK073551_A_en ELECTRONIC CONTROL BOX TECHNICAL DATA MODEL K 4/M/2-EL EVO2 Thermal power min. 1°st. / min. 2°st. - max. 2°st. * [Mcal/h] 100/200-450 Thermal power min. 1°st. / min. 2°st. - max. 2°st. * [kW] 116/232-523 Gas flow G20 (NATURAL GAS) min. 1°st. / min. 2°st. - max. 2°st. * [Nm³/h] 11.7/23.4-52.6 Gas flow G31 (L.P.G.) min. 1°st. / min. 2°st. - max. 2°st. * [Nm³/h] 4.5/9-20.3 LIGHT-OIL flow min. 1°st. / min. 2°st. - max. 2°st. * [kg/h] 10/20-45 Fuel: NATURAL GAS (second family) - L.P.G. (third family) Fuel category: I2R,I2H,I2L,I2E,I2E+,I2Er,I2ELL,I2E(R) I3B/P,I3+,I3P,I3B,I3R Intermitted working operation (min. 1 stop every 24 hours) modulating gas - two stage light-oil Environmental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max. temperature combustion air [°C] 60 Minimum pressure gas train D1" - S NATURAL GAS/LPG ** [mbar] 95/60 Minimum pressure gas train D1"1/4 - S NATURAL GAS/LPG ** [mbar] 54.5/44 Minimum pressure gas train D1"1/2 -S NATURAL GAS/LPG ** [mbar] 28/33 Minimum pressure gas train D2" -S NATURAL GAS/LPG ** [mbar] 26.5/33 Maximum pressure at the entry of valves (Pe. max) [mbar] 360 Nominal electric power [W] 800 Fan motor [W] 550 Pump motor [W] 180 Nominal absorption auxiliary [A] 0.7 Power supply: 3~400V,1N~230V-50Hz Electric protection degree: IP 40 Noisiness *** min. - max. [dB(A)] 73-76 * Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** Minimal feeding-gas pressure to the gas train to get the maximum power of the burner, considering counter-pressure in combustion chamber of value 0 (zero). *** Measured sonorous pressure in the laboratory combustion, with functional burner on beta boiler to 1 metre of distance (UNI EN ISO 3746 - Control method Class 3 - Tolerance on the measured sound pressure can be assumed equal to ± 1 [dB (A)]). K 4/M/2-EL EVO2 DUAL FUEL GAS/LIGHT-OIL BURNERS WITH SK073551_A_en ELECTRONIC CONTROL BOX OPERATING RANGE DIAGRAM ΀ŵďĂƌ΁ ϵ͕ϱ ϴ͕ϱ K 4/M/2-EL EVO2 ϳ͕ϱ ϲ͕ϱ ϱ͕ϱ ϰ͕ϱ ϯ͕ϱ Ϯ͕ϱ ϭ͕ϱ Ϭ͕ϱ ͲϬ͕ϱ ϱϬ ϭϱϬ ϮϱϬ ϯϱϬ ϰϱϬ ϱϱϬ ϲϱϬ ΀Ŭt΁ Fig. X = Thermal power Y = Pressure in combustion chamber The firing rates has been obtained based on test boilers in accordance with EN676 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner bruciatore, combustion chamber dimensions must be in accordance with current regulation. In case of non-compliance, contact the manufacturer. K 4/M/2-EL EVO2 DUAL FUEL GAS/LIGHT-OIL BURNERS WITH SK073551_A_en ELECTRONIC CONTROL BOX DIMENSIONS [MM] L A H Rd I D R1 G B C TC - TL * E R4 R2 F R3 Fig. Dimensions MODEL A B C D E F G H I L R1 R2 R3 R4 RD Gas train weight K 4/M/2-EL EVO2 25 290 525 150 100 750 450 155 200 207 240 415 492 360 Rp1 1/2 25 kg * TC-TL: see chapter "FLAME TUBE LENGTH" BOILER PLATE ** Suggested dimension of connection between burner and generator. Fig. Boiler plate MODEL L min L max M N min N** N max K 4/M/2-EL EVO2 mm 205 226 M10 160 160 185 FLAME TUBE LENGTH Flame tube length must be selected based on the specifications supplied by boiler manufacturer and, in any case, it must be greater than the thickness of the boiler door included its insulation. In case of boilers with flame inversion or front flue combustion chambers, it is necessary to insulate the area between the flame tube and front door with refractory material. This protection material must not impede flame tube extraction. MODEL TC TL *** K 4/M/2-EL EVO2 mm 250 350 *** For different flame lengths, please contact our Technical-Sales Department. K 4/M/2-EL EVO2 DUAL FUEL GAS/LIGHT-OIL BURNERS WITH SK073551_A_en ELECTRONIC CONTROL BOX PRODUCT SPECIFICATION SHORT DESCRIPTION Dual fuel gas/light-oil burners with electric control box. DETAILED SPECIFICATION Dual fuel gas/light-oil burners with electric control box, composed by: • Light-oil fuel: two-stage operation; • Gas fuel: two-stage progressive or modulating operation (PID fully modulating) if equipped with the additional modulation kit and probe • Servo-controlled gas ball valve; progressive opening and free passage with total opening; • Servo motor for gas ball valve; • Predisposition for the addition of a specific kit that allows the operation to be transformed into modulating, i.e. the possibility of delivering any power value between minimum and maximum, depending on the instantaneous demand of the load; • Aluminium frame; • Fan at high pressurisation; •…

Dokumen Teknis

Tidak ada dokumen teknis yang tersedia untuk produk ini.
Minta dokumentasi
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

FBR Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

Pembakar industri FBR K 4/M/2 EL EVO2 adalah unit dual fuel gas/light-oil yang dilengkapi dengan electronic control box untuk pengoperasian 2 tahap sliding atau modulating. Dengan daya termal 100/200-450 Mcal/h dan daya listrik nominal 3,5 W, burner ini mendukung suplai listrik 3~400V atau 1N~230V serta konsumsi gas 11,7/23,4-52,6. Dirancang untuk aplikasi ketel uap dan peralatan pembakaran, produk ini menawarkan efisiensi tinggi dengan bobot 11 kg dan perlindungan IP40.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Untuk apa FBR K 4/M/2 EL EVO2 digunakan?

Burner ini digunakan sebagai pembakar industri dual fuel gas/light-oil untuk ketel uap dan peralatan pembakaran. Dengan pengoperasian 2 tahap sliding atau modulating, ia cocok untuk aplikasi yang memerlukan penyesuaian daya termal antara 100 hingga 450 Mcal/h.

Apa spesifikasi teknis FBR K 4/M/2 EL EVO2?

Spesifikasi meliputi daya termal 100/200-450 Mcal/h, daya kipas 2,2 kW, daya pompa 750 kW, konsumsi gas 11,7/23,4-52,6, suplai listrik 3~400V atau 1N~230V, arus 6,8 A, bobot 11 kg, dan perlindungan IP40. Suhu udara pembakaran maksimal 60°C.

Di mana beli FBR K 4/M/2 EL EVO2 di Indonesia?

Anda dapat membeli FBR K 4/M/2 EL EVO2 melalui 3G Electric, distributor resmi yang memasok dan mengirimkan peralatan industri ini ke seluruh Indonesia. Kami menangani logistik dan bea cukai untuk memastikan produk sampai ke lokasi Anda.

Bagaimana cara memilih FBR K 4/M/2 EL EVO2 yang tepat?

Pilih berdasarkan kebutuhan daya termal Anda, antara 100 hingga 450 Mcal/h, dan jenis bahan bakar (gas alam atau LPG). Pastikan suplai listrik sesuai (3~400V atau 1N~230V) dan perhatikan perlindungan IP40 untuk lingkungan operasi.

Apa keunggulan FBR K 4/M/2 EL EVO2 dibandingkan burner lain?

Keunggulan termasuk pengoperasian dual fuel gas/light-oil dengan 2 tahap sliding atau modulating, electronic control box untuk penyesuaian kurva udara/gas, dan desain kompak dengan akses mudah untuk perawatan. Ini memastikan efisiensi pembakaran tinggi dan stabilitas nyala api.

Digunakan dalam

Aplikasi umum untuk FBR
Hospitality and commercial HVAC — cast-iron boiler plants in hotels and shopping complexes
Pharmaceutical and biotech process heat — gas-fired burners with ATEX gas trains for classified-zone requirements
Medical-waste and bio-hazard incineration — FGP progressive dual-fuel systems
Food and beverage steam boilers — single-stage G-series for continuous-duty cycles
Marine and offshore platforms — IP54-rated X-series for high-humidity marine operations

FBR Produk

3G Electric memasok FBR burners & combustion. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Rangkaian Gas & Katup Gas Transformator Pengapian Kontrol Pembakar Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
K 4/M/2 TC EL EVO 2 | Variant: variant_2 | Subgroup: Burner
FBR
K 4/M/2 TC EL EVO 2 | Variant: variant_2 | Subgroup: Burner
K 4/2 TL EVO 2 | Variant: variant_2 | Subgroup: Burner
FBR
K 4/2 TL EVO 2 | Variant: variant_2 | Subgroup: Burner
K 4/2 TC EVO 2 | Variant: variant_2 | Subgroup: Burner
FBR
K 4/2 TC EVO 2 | Variant: variant_2 | Subgroup: Burner
K X5/M/2 TL EL | Variant: variant_2 | Subgroup: Burner
FBR
K X5/M/2 TL EL | Variant: variant_2 | Subgroup: Burner
K X6/M EVO TL | Variant: variant_2 | Subgroup: Burner
FBR
K X6/M EVO TL | Variant: variant_2 | Subgroup: Burner
K X6/2 EVO TL | Variant: variant_2 | Subgroup: Burner
FBR
K X6/2 EVO TL | Variant: variant_2 | Subgroup: Burner

Lainnya dari FBR

Lihat semua FBR suku cadang
FBR
FBR
K 350/M TL
FBR
FBR
G 0S LX TC
FBR
FBR
G X5 F TL
FBR
FBR
G X4.22 LX TL
FBR
FBR
K X6/M EL EVO TL
FGP 1500/M TL MEC
FBR
FGP 1500/M TL MEC
FGP 75/2 LX TC
FBR
FGP 75/2 LX TC
FBR
FBR
K 250/M TL EL