Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

STANDARD XCHANGE P4-40-TL Gasketed Plate Heat Exchanger, 55 gpm, 16.36 sq ft - Plate & Frame Heat Exchangers
STANDARD XCHANGEPlate & Frame Heat Exchangers

STANDARD XCHANGE P4-40-TL Gasketed Plate Heat Exchanger, 55 gpm, 16.36 sq ft

STANDARD XCHANGE menghadirkan Gasketed Plate Heat Exchanger tipe P4-40-TL, sebuah penukar panas pelat dan rangka yang dirancang untuk aplikasi industri dengan kapasitas 1.056.600 BtuH untuk air dan 171.900 BtuH untuk…

SKU 3G-OTH-62872

Juga terdaftar sebagai: P440TL · P4 40 TL

Merek
STANDARD XCHANGE
Item
P4-40-TL Gasketed Plate Heat Exchanger, 55 gpm, 16.36 sq ft
Kategori
Plate & Frame Heat Exchangers
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

STANDARD XCHANGE
Manufacturer Part Number
P4-40-TL
Type
55 gpm, 16.36 sq ft

Dokumen Teknis

Tidak ada dokumen teknis yang tersedia untuk produk ini.
Minta dokumentasi
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

STANDARD XCHANGE Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

STANDARD XCHANGE menghadirkan Gasketed Plate Heat Exchanger tipe P4-40-TL, sebuah penukar panas pelat dan rangka yang dirancang untuk aplikasi industri dengan kapasitas 1.056.600 BtuH untuk air dan 171.900 BtuH untuk oli. Unit ini memiliki laju alir 55 gpm dan luas permukaan perpindahan panas 16,36 sq ft, menjadikannya solusi efisien untuk sistem pemanas atau pendingin di sektor kelapa sawit, semen, dan pengolahan makanan. Cari plate heat exchanger untuk kebutuhan industri Anda? Produk ini siap mendukung operasional pabrik Anda.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Apa spesifikasi STANDARD XCHANGE P4-40-TL?

STANDARD XCHANGE P4-40-TL adalah Gasketed Plate Heat Exchanger dengan kapasitas 1.056.600 BtuH untuk air dan 171.900 BtuH untuk oli. Spesifikasinya meliputi laju alir 55 gpm dan luas permukaan 16,36 sq ft. Produk ini cocok untuk aplikasi pertukaran panas industri.

Untuk apa Gasketed Plate Heat Exchanger digunakan?

Gasketed Plate Heat Exchanger digunakan untuk memindahkan panas antara dua fluida, seperti air dan oli, dalam sistem pemanas atau pendingin industri. STANDARD XCHANGE P4-40-TL dirancang untuk aplikasi dengan kapasitas 1.056.600 BtuH untuk air dan 171.900 BtuH untuk oli, ideal untuk ketel uap atau proses manufaktur.

Di mana beli STANDARD XCHANGE P4-40-TL di Indonesia?

Anda dapat membeli STANDARD XCHANGE P4-40-TL melalui 3G Electric, distributor resmi yang memasok dan mengirimkan produk ini ke seluruh Indonesia. Kami menangani logistik dan bea cukai untuk memastikan pengiriman tepat waktu ke lokasi pabrik Anda.

Bagaimana cara memilih plate heat exchanger yang tepat?

Pilih plate heat exchanger berdasarkan kapasitas termal, laju alir, dan jenis fluida. STANDARD XCHANGE P4-40-TL menawarkan kapasitas 1.056.600 BtuH untuk air dan 171.900 BtuH untuk oli dengan laju alir 55 gpm dan luas permukaan 16,36 sq ft, cocok untuk aplikasi industri yang membutuhkan efisiensi tinggi.

Digunakan dalam

Aplikasi umum untuk STANDARD XCHANGE
HVAC systems — STANDARD XCHANGE SX2000 series shell-and-tube heat exchangers for building cooling loops
Process cooling — STANDARD XCHANGE SN503008 series brass-shell units for industrial water cooling at 105 gpm
Maintenance and retrofit — STANDARD XCHANGE 810RG7 Nitrile HT gaskets for plate heat exchanger rebuilds
Hydronic heating — STANDARD XCHANGE copper-tube heat exchangers for boiler-to-water heat transfer
Oil cooling — STANDARD XCHANGE shell-and-tube units with carbon steel shells for lubricating oil systems

STANDARD XCHANGE Produk

3G Electric memasok STANDARD XCHANGE plate & frame heat exchangers. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Pembakar & Pembakaran Pompa & Kompresor Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
Gasketed plate and frame heat exchanger rated for 86 gpm flow and 61.35 sq ft surface area. Designed for liquid-to-liquid heat transfer in industrial processes such as water heating, oil cooling, and thermal management in HVAC and chemical processing systems
STANDARD XCHANGE
Gasketed plate and frame heat exchanger rated for 86 gpm flow and 61.35 sq ft surface area. Designed for liquid-to-liquid heat transfer in industrial processes such as water heating, oil cooling, and thermal management in HVAC and chemical processing systems
Plate and frame heat exchanger rated for 48 gpm flow and 32.72 sq ft of heat transfer surface. Capable of handling 1,811,000 BtuH with water or 294,700 BtuH with oil. Used for transferring thermal energy between two fluids without mixing in HVAC, oil cooling, and process heating applications
STANDARD XCHANGE
Plate and frame heat exchanger rated for 48 gpm flow and 32.72 sq ft of heat transfer surface. Capable of handling 1,811,000 BtuH with water or 294,700 BtuH with oil. Used for transferring thermal energy between two fluids without mixing in HVAC, oil cooling, and process heating applications
Gasketed plate and frame heat exchanger rated for 108 gpm flow and 77.5 sq ft surface area. Suitable for water-to-water or oil-to-water heat transfer in industrial processes such as hydraulic cooling, lube oil systems, and process heating
STANDARD XCHANGE
Gasketed plate and frame heat exchanger rated for 108 gpm flow and 77.5 sq ft surface area. Suitable for water-to-water or oil-to-water heat transfer in industrial processes such as hydraulic cooling, lube oil systems, and process heating
Gasketed plate and frame heat exchanger rated for 2,861,000 BtuH on water duty and 510,500 BtuH on oil duty. Flow capacity of 65 gpm with a heat transfer area of 45.21 sq ft. Used for transferring heat between two fluids in HVAC, oil cooling, and process heating applications
STANDARD XCHANGE
Gasketed plate and frame heat exchanger rated for 2,861,000 BtuH on water duty and 510,500 BtuH on oil duty. Flow capacity of 65 gpm with a heat transfer area of 45.21 sq ft. Used for transferring heat between two fluids in HVAC, oil cooling, and process heating applications
Gasketed plate heat exchanger rated for 99 gpm flow with 66.31 sq ft heat transfer area. Delivers 4,500,800 BtuH for water and 630,800 BtuH for oil. Used in HVAC, power generation, and manufacturing for efficient thermal exchange between fluids
STANDARD XCHANGE
Gasketed plate heat exchanger rated for 99 gpm flow with 66.31 sq ft heat transfer area. Delivers 4,500,800 BtuH for water and 630,800 BtuH for oil. Used in HVAC, power generation, and manufacturing for efficient thermal exchange between fluids
Plate and frame heat exchanger rated for 38 gpm flow and 24.11 sq ft of heat transfer surface. Delivers 1,341,600 BtuH with water and 214,300 BtuH with oil. Suitable for hydraulic oil cooling, lube oil systems, and process heating or cooling in industrial fluid processing applications
STANDARD XCHANGE
Plate and frame heat exchanger rated for 38 gpm flow and 24.11 sq ft of heat transfer surface. Delivers 1,341,600 BtuH with water and 214,300 BtuH with oil. Suitable for hydraulic oil cooling, lube oil systems, and process heating or cooling in industrial fluid processing applications

Lainnya dari STANDARD XCHANGE

Lihat semua STANDARD XCHANGE suku cadang
Gasketed plate and frame heat exchanger rated for 12,809,200 BtuH with water and 1,742,400 BtuH with oil. Flow capacity of 250 gpm with 184.71 sq ft heat transfer area. Used for thermal exchange between fluids in HVAC, industrial processing, and power generation systems
STANDARD XCHANGE
Gasketed plate and frame heat exchanger rated for 12,809,200 BtuH with water and 1,742,400 BtuH with oil. Flow capacity of 250 gpm with 184.71 sq ft heat transfer area. Used for thermal exchange between fluids in HVAC, industrial processing, and power generation systems
Plate and frame heat exchanger rated for 770 gpm flow and 304.83 sq ft of heat transfer area. Delivers 23,441,900 BtuH with water and 3,462,900 BtuH with oil. Used for transferring heat between fluids in industrial processes such as HVAC, power generation, and manufacturing
STANDARD XCHANGE
Plate and frame heat exchanger rated for 770 gpm flow and 304.83 sq ft of heat transfer area. Delivers 23,441,900 BtuH with water and 3,462,900 BtuH with oil. Used for transferring heat between fluids in industrial processes such as HVAC, power generation, and manufacturing
Plate and frame heat exchanger with copper-brazed aluminum plates and steel connections. Rated for 60 gpm flow and 7.5 sq ft heat transfer surface. Suitable for transferring heat between fluids in HVAC, process cooling, and oil heating or cooling systems
STANDARD XCHANGE
Plate and frame heat exchanger with copper-brazed aluminum plates and steel connections. Rated for 60 gpm flow and 7.5 sq ft heat transfer surface. Suitable for transferring heat between fluids in HVAC, process cooling, and oil heating or cooling systems
Plate and frame heat exchanger rated for 765 gpm flow and 872.85 sq ft surface area. Designed for heat transfer between water and oil in industrial processes such as HVAC, power generation, and chemical processing
STANDARD XCHANGE
Plate and frame heat exchanger rated for 765 gpm flow and 872.85 sq ft surface area. Designed for heat transfer between water and oil in industrial processes such as HVAC, power generation, and chemical processing
Gasketed plate heat exchanger rated for 1,724,000 BtuH with water and 323,300 BtuH with oil. Handles 44 gpm flow with 29.03 sq ft of heat transfer surface area. Used for transferring thermal energy between two fluids in HVAC, process heating, and oil cooling applications
STANDARD XCHANGE
Gasketed plate heat exchanger rated for 1,724,000 BtuH with water and 323,300 BtuH with oil. Handles 44 gpm flow with 29.03 sq ft of heat transfer surface area. Used for transferring thermal energy between two fluids in HVAC, process heating, and oil cooling applications
This plate and frame heat exchanger is designed for transferring heat between fluids in industrial HVAC, process cooling, and oil heating systems. It features a copper-brazed aluminum plate construction with steel connections, rated at 80 gpm flow rate and 10.2 sq ft heat transfer area, with a capacity of 26,800 BtuH for oil applications
STANDARD XCHANGE
This plate and frame heat exchanger is designed for transferring heat between fluids in industrial HVAC, process cooling, and oil heating systems. It features a copper-brazed aluminum plate construction with steel connections, rated at 80 gpm flow rate and 10.2 sq ft heat transfer area, with a capacity of 26,800 BtuH for oil applications
This plate and frame heat exchanger is rated for 405,000 BtuH water-to-water duty at 94 gpm flow. It features 92.2 sq ft of surface area with copper-brazed aluminum plates and steel connections. Suitable for use in HVAC, process cooling, and hydronic heating systems where compact and efficient heat transfer is required
STANDARD XCHANGE
This plate and frame heat exchanger is rated for 405,000 BtuH water-to-water duty at 94 gpm flow. It features 92.2 sq ft of surface area with copper-brazed aluminum plates and steel connections. Suitable for use in HVAC, process cooling, and hydronic heating systems where compact and efficient heat transfer is required
Gasketed plate and frame heat exchanger rated for 15,524,700 BtuH with water and 2,157,300 BtuH with oil. Handles 303 gpm flow with 232.07 sq ft of heat transfer surface area. Suitable for transferring heat between fluids in HVAC, power generation, and manufacturing processes
STANDARD XCHANGE