TRACXP Calibration Gas: TXP-T40, Air, Cylinder, 58 L Cylinder Capacity, Hydrogen Sulfide 5 ppm
The TRACXP TXP-CAL-H2S-5PPM is a calibration gas cylinder for use with the TXP-T40 fixed gas detector. It contains a mixture of Hydrogen Sulfide at 5 ppm in an Air background, with a 58 L cylinder capacity. This…
SKU 3G-OTH-551889
- 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
- Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
- Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Butuh bantuan pemasangan atau rekayasa?
Ajukan pertanyaan
Deskripsi Produk
The TRACXP TXP-CAL-H2S-5PPM is a calibration gas cylinder for use with the TXP-T40 fixed gas detector. It contains a mixture of Hydrogen Sulfide at 5 ppm in an Air background, with a 58 L cylinder capacity. This product is designed to verify and calibrate the TXP-T40 sensor's response to H2S.
Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.
Pertanyaan yang Sering Diajukan
What is TRACXP TXP-CAL-H2S-5PPM calibration gas used for?
The TRACXP TXP-CAL-H2S-5PPM calibration gas is used to verify and calibrate the TXP-T40 fixed gas detector's response to hydrogen sulfide. It contains 5 ppm H2S in an air background, with a 58 L cylinder capacity, ensuring accurate sensor performance in industrial safety applications.
What are the specifications of TRACXP TXP-CAL-H2S-5PPM?
The TRACXP TXP-CAL-H2S-5PPM calibration gas has a gas mixture of hydrogen sulfide at 5 ppm, background gas of air, and a cylinder capacity of 58 L. It is designed for use with the TXP-T40 fixed gas detector and is supplied as a non-refillable cylinder.
Where to buy TRACXP TXP-CAL-H2S-5PPM calibration gas worldwide?
3G Electric supplies the TRACXP TXP-CAL-H2S-5PPM calibration gas worldwide. As a global industrial solutions provider, we handle full logistics, customs clearance, and delivery to your facility. Contact us for pricing and lead time on this calibration gas cylinder.
How to use TRACXP TXP-CAL-H2S-5PPM for calibrating a TXP-T40 detector?
To calibrate a TXP-T40 detector with TRACXP TXP-CAL-H2S-5PPM, connect the regulator to the cylinder, apply the gas at the specified flow rate, and follow the detector's calibration procedure. Always verify the cylinder's expiration date and use in a well-ventilated area per safety guidelines.
TRACXP Produk
3G Electric memasok TRACXP calibration gases for fixed gas detectors. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.









