Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

Eclipse logo

Eclipse

USABurners & Combustion

Eclipse manufactures ignition and sensing electrodes for industrial combustion equipment, with product lines serving burner control systems, gas ignition assemblies, and flame-detection applications. The range includes standard and custom ignition electrodes, spark plugs, ionization probes, and related flame-safeguard components designed for integration into industrial burners, boilers, furnaces, and process-heating equipment across manufacturing, petrochemical, and utility sectors. Eclipse electrodes are specified by dimensional standard (thread pitch, electrode gap, probe length) and material composition to match specific combustion-chamber geometry and ignition-voltage requirements. Products are rated for continuous operation in high-temperature environments and are compatible with standard ignition-transformer outputs (typically 4–10 kV). Each SKU is identified by Eclipse's reference designation, allowing cross-verification with OEM equipment documentation and service bulletins. Stock availability covers both metric-threaded and fractional-inch fastener patterns. Technical specifications are accessible via Eclipse reference number, supporting direct equipment pairing and retrofit planning

Asli
Suku Cadang OEM
Ahli
Dukungan Teknis
1 Hari
Respons Penawaran
USA
Asal
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis & gambar
Respons Penawaran 1 Hari
Tim berbasis di Singapore
Stok siap tersedia & bea cukai ditangani6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.Pengiriman ke: Jakarta, Surabaya, Bandung, Medan, Batam
Jelajahi:
Tampilkan
Halaman 5 dari 6

Tentang Eclipse

Eclipse manufactures ignition and sensing electrodes for industrial combustion equipment, with product lines serving burner control systems, gas ignition assemblies, and flame-detection applications. The range includes standard and custom ignition electrodes, spark plugs, ionization probes, and related flame-safeguard components designed for integration into industrial burners, boilers, furnaces, and process-heating equipment across manufacturing, petrochemical, and utility sectors. Eclipse electrodes are specified by dimensional standard (thread pitch, electrode gap, probe length) and material composition to match specific combustion-chamber geometry and ignition-voltage requirements. Products are rated for continuous operation in high-temperature environments and are compatible with standard ignition-transformer outputs (typically 4–10 kV). Each SKU is identified by Eclipse's reference designation, allowing cross-verification with OEM equipment documentation and service bulletins. Stock availability covers both metric-threaded and fractional-inch fastener patterns. Technical specifications are accessible via Eclipse reference number, supporting direct equipment pairing and retrofit planning

Aplikasi Umum

  • Industrial boiler ignition control — Eclipse ignition electrodes (00.7030022.01/02) for pilot-light initiation in large water-tube and fire-tube boilers
  • Process furnace burner retrofit — M14 spark plugs (EC23045) for gas-fired radiant-tube and indirect-heat furnace systems
  • Flame-safeguard monitoring — Ionization probes (10002242-1) for continuous flame detection in modulating burner controls and burner management systems
  • Oil-gas dual-fuel systems — R1/4" threaded ignition electrodes for transition between oil-mist and gas ignition modes in utility and marine power generation
  • Emergency burner replacement — Stock Eclipse electrode variants held for planned maintenance and unscheduled emergency shutdown recovery in food processing and chemical manufacturing
Asal: Diproduksi di USA

Merek-merek terkait yang kami sediakan

Produsen yang sebanding dalam kategori produk yang sama.

Pertanyaan yang Sering Diajukan

Pertanyaan umum tentang Eclipse dari 3G Electric.

What is the difference between Eclipse ignition electrodes and ionization probes?

Ignition electrodes (such as 00.7030022.01 and R1/4x43 types) generate a spark to initiate fuel combustion, requiring high-voltage (typically 4–10 kV) pulses from an ignition transformer. Ionization probes (e.g., reference 10002242-1) detect the presence of flame after ignition by measuring ion conductivity in the combustion zone, feeding a signal back to the burner control system. Ignition electrodes are consumable and subject to erosion; probes are typically longer-lived but must be positioned in the flame envelope.

How do I identify the correct Eclipse electrode reference for my burner?

Start with your equipment's original service manual or nameplate, which should list the Eclipse reference number (e.g., 00.7030022.01 or EC23045). If the reference is unknown, note the thread pitch (M14, R1/4"), overall length, and electrode gap distance, then cross-reference with Eclipse's technical documentation or contact us with a photograph and burner model number. We hold SKUs for common industrial burner platforms and can assist with dimensional matching.

What causes Eclipse electrode premature failure in the field?

Common failure modes include carbon buildup or fouling (caused by incomplete combustion or fuel contamination), thermal shock from rapid on-off cycling, mechanical vibration leading to crack initiation at the threaded base, and incorrect electrode gap setting. High-frequency ignition demand, water ingress into the electrode cavity, and exceeding the transformer voltage rating accelerate wear. Regular inspection and cleaning during scheduled maintenance extend service life; replacement intervals vary by duty cycle and fuel quality.

Are Eclipse M14 spark plugs interchangeable with automotive plugs?

No. Eclipse industrial spark plugs (e.g., EC23045 M14 L=101mm) are designed for burst-ignition service in burner controls, not continuous automotive ignition. The electrode gap, insulator material, and thermal range are optimized for combustion-chamber pressure and temperature profiles specific to industrial furnaces and boilers. Using automotive plugs in industrial equipment may result in misfire, fouling, or thermal damage.

What does the reference number (e.g., 00.7030022.01 vs. 00.7030022.02) indicate on Eclipse electrodes?

Eclipse reference numbers encode design revisions and dimensional variants. The suffix (.01, .02) typically indicates a change in electrode gap, wire diameter, insulator material, or thread geometry. Without access to Eclipse's full technical matrix, we recommend verifying compatibility against your equipment OEM documentation or submitting a photo of the removed electrode to confirm the exact replacement.

Can Eclipse electrodes be repaired or cleaned instead of replaced?

Ignition electrodes may be safely cleaned of light carbon deposits using a soft brass brush and solvent in a well-ventilated area, but erosion of the electrode tip itself cannot be reversed. Once the gap widens beyond the design tolerance (typically 0.8–1.2 mm), spark reliability declines and replacement is necessary. Ionization probes should not be sanded or filed, as damage to the ceramic insulator may cause leakage current and false flame signals.