Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

CBM Refrigerant gas detector EL520 - HVAC & Refrigeration
CBMHVAC & Refrigeration

CBM Refrigerant gas detector EL520

CBM AccuTools™ eL-520 adalah detektor kebocoran gas refrigeran yang dirancang untuk teknisi AC dan sistem refrigerasi. Dengan sensitivitas < 3 g/tahun, alat ini mampu mendeteksi kebocoran sekecil 0,1 oz/tahun pada…

SKU 3G-CBM-01082

Juga terdaftar sebagai: CLI 20204 · CLI-20204

Merek
CBM
Item
Refrigerant gas detector EL520
Kategori
HVAC & Refrigeration
UNSPSC
40101701 — Air conditioners
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

CBM
batteries
2 x 1.5V AA Alkaline
sensitivity
< 3 g/year
battery life
40 hours
probe length
300 mm
response time
instantaneous
sensor lifetime
approx. 30 hours
detected refrigerants
R134A, R12, R22, R32, R1234yf, R404A, R408A, R409A, R410A

Konten Lembar Data

eL-520 3G-CBM-01082 Refrigerant Gas Leak Detector User’s Guide eL-520 User’s Guide Congratulations on the purchase of the AccuTools™ eL-520 Refrigerant Gas Leak Detector, the most technologically advanced of its kind. The eL-520’s low power requirements, small size and high sensitivity combine to create a tool which is easy to handle and ultra effective at locating even the most difficult-to-find leaks. Fully SAE J1627 compliant, the eL-520 will detect leaks as small as 0.1 oz/yr (3g/year) in R12, R22, R134a and other halogen refrigerant systems. The eL-520 should not be used on systems that contain flammable refrigerants such as Propane, Isobutane, etc. TECHNICAL DATA Dimensions 7.25” x 2.25” x 1.5” (19 cm x 5.7 cm x 3.8 cm) Weight 7 oz. (190 grams) Batteries 2 x 1.5V 'AA' Alkaline Batteries (3 VDC) Battery Life 40 hours Sensitivity < 3g/year (0.1 oz/yr) Sensor lifetime approx. 30 hours Operating temperature 32 – 122°F (0 – 50°C) Warm up time < 2 sec. Response time instantaneous Reset time instantaneous Probe length 12” (30 cm) It detects all HFC, CFC and HCFC refrigerants including R134A, R12, R22, R32, R1234yf as well as blends such as R404A, R408A, R 409A, R 410A, and others. 1 eL-520 User’s Guide INSTRUCTIONS 1. Press the button to turn the unit on. 2. The LED will flash orange for a short moment to indicate auto-reset, afterwards the unit will begin beeping and flashing green. 3. To reset the unit to the existing level of ambient refrigerant, press and release the button. The LED will flash orange briefly to indicate the reset. All levels of refrigerant less than the reset level will be ignored. 4. Unit turns on in the low sensitivity level, which is adequate for most leaks. Press the button twice (double-click like a computer mouse). The LED will fade from red to green and a sweeping sound effect of low to high pitch will be heard. The sensitivity is now set for 3g/year (0.1oz/yr). This mode should only be used for looking for leaks of less than 14g/year (0.5 oz/yr). 5. Double click again to change back to low sensitivity. 6. Move the probe towards a suspected refrigerant leak at a rate of less than 2 inches (50 mm) per second, no more than ¼ inch (5 mm) away from the suspected source. 7. If a leak exists, the sound will increase in rate and pitch and the LED will start flashing rapidly. 8. To turn the eL-520 off, press and hold the button for 3 seconds. 2 eL-520 User’s Guide FEATURES Ÿ If the sensor is damaged, a sweeping alarm and a red-green flash will indicate the problem. Ÿ A flashing LED during normal operation also reflects the battery level: Green: batteries are fresh Orange: batteries should be changed • If the batteries are nearly empty, the LED will turn solid red and a two-tone alarm will be noted for 5 seconds, before the eL-520 will power itself off. Ÿ If the unit is left on unattended, it will automatically turn off after about 5 minutes to conserve batteries. BATTERY INSTALLATION AND REPLACEMENT 1. Turn the power off. 2. Remove the battery cover from the back of the instrument by loosening the battery cover screw and lifting the battery cover off. Be careful not to lose the extra sensor stored in the battery compartment. 3. Insert 2 size ‘AA’ alkaline batteries, observing proper battery polarity. 4. Replace battery cover and tighten battery cover screw. 3 eL-520 User’s Guide SENSOR An eL-520 sensor will last between 25 and 30 hours of continuous use. A failed or failing sensor will be indicated in one of the following ways: 1. Unstable or erratic operation of the unit and many false alarms, even in pure air. 2. A continuous “siren” sound. SENSOR REPLACEMENT In either case, replacement of the sensor is necessary: 1. Turn the power off. 2. Locate the replacement sensor in the battery compartment. 3. Unscrew (turn counter clockwise) the old sensor from the 4. end of the probe. 5. Screw (turn clockwise) the new sensor into place. Replacement sensors Part Number ELS-5 (pack of 2) MAINTENANCE The eL-520 should provide years of service with little maintenance aside from changing batteries and sensors. The case may be cleaned with a shop towel moistened with water and a mild detergent. Do not use solvent of any kind. 4 eL-520 User’s Guide SAE J1628 RECOMMENDED PROCEDURES For the purpose of Automotive A/C Testing with respect to the SAE J1627 standard, the following leak testing procedure applies: 1. Operate the eL-520 in high sensitivity mode. 2. Leak test with the engine not in operation. 3. The air conditioning system shall be charged with sufficient refrigerant to have a gauge pressure of at least 340 kPa when not in operation. At temperatures below 15°C, leaks may not be measurable, since this pressure may not be reached. 4. Take care not to contaminate the detector probe tip. If the part is particularly dirty, it should be wiped off with a dry shop towel or blown off with shop air. No cleaners or solvents shall be used, since many electronic detectors are sensitive to their ingredients. 5. Visually trace the entire refrigerant system, and look for signs of air-conditioning lubricant leakage, damage, and corrosion on all lines, hoses, and components. Each questionable area shall be carefully checked with the detector probe, as well as all fittings, hose to line couplings, refrigerant controls, service ports with caps in place, brazed or welded areas, and areas around attachment points and hold-downs on lines and components. 6. Always follow the refrigerant system around in a continuous path so that no areas of potential leaks are missed. If a leak is found, always continue to test the remainder of the system. 5 eL-520 User’s Guide 7. At each area checked, the probe shall be moved around the location, at a rate no more than 25-50 mm/s and no more than 5 mm from the surface completely around the position. Slower and closer movement of the probe often helps locate the exact position of the leak. 8. An apparent leak shall be verified at least once by blowing shop air into the area of the suspected leak, if necessary, and repeating the check of the area. In cases of very large leaks, blowing out the area with shop air often helps locate the exact position of the leak. 9. Leak testing of the evaporator core while in the air conditioning module shall be accomplished by turning the air conditioning blower on high for a period of 15 sec. minimum, shutting it off, then waiting for the refrigerant to accumulate in the case for time specified by paragraph 10, then inserting the leak detector probe into the blower resistor block or condensate drain hold if no water is present, or into the closest opening in the heating/ventilation/air conditioning case to the evaporator, such as the heater duct or a vent duct. If the detector alarms, a leak apparently has been found. 10. The accumulation time shall be 10 minutes. 11. Following any service to the refrigerant system of the vehicle, and any other service which disturbs the refrigerant system, a leak test of the repair and of the service ports of the refrigerant system shall be done. 6 Declaration of Conformity in accordance with European Standard EN 14624:2005 It is hereby certified that AccuTools model number eL-520 Refrigerant Leak Detector has been tested and is declared in conformance to European Standard EN 14624:2005 Performance Of Mobile Leak Detectors Of Halogenated Refrigerants. Testing has been conducted using test equipment as defined by relevant standards, using an NIST traceable leak source. The unit met the sensitivity, accuracy and performance requirements defined by the standard as described below: Stationary Test Threshold < 3 g/yr Moving Test Threshold < 3 g/yr Signed: Dated: April 14, 2009 Declaration of Conformity im accordance with Council Directive 89/336 EEC, 92/3L/EEC We, Manufacturer/Importer Company Name: CORE ENTERPRISES, INC. Company Address: 3650 CORAL RIDGE DR., SUITE 101 CORAL SPRINGS, FL 33065 U.S.A. Trade Name: ACCUTOOLS declare that the product Product Name: REFRIGERANT GAS LEAK DETECTOR Model Number: eL-520 Comment Issues: -- is in conformity with EMC requirements on the basis of EN 61326: 1998/A2:2002 EN 55011: 1998/A1:2000 (Class B) TEC 61000-4-2:1995/A1:1998/A2:2000 IEC 61000-4-3:1995/A1:1998/A2:2000 Manufacturer/Importer Signature: C . f aa Date: January 5, 2007 Name: Cornel Opris
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

CBM Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

CBM AccuTools™ eL-520 adalah detektor kebocoran gas refrigeran yang dirancang untuk teknisi AC dan sistem refrigerasi. Dengan sensitivitas < 3 g/tahun, alat ini mampu mendeteksi kebocoran sekecil 0,1 oz/tahun pada berbagai refrigeran seperti R134A, R22, R32, R410A, dan lainnya. Dilengkapi probe sepanjang 300 mm, respons instan, serta baterai 2 x 1,5V AA Alkaline dengan daya tahan 40 jam, eL-520 menjadi pilihan andal untuk perawatan sistem pendingin Anda.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Untuk apa CBM eL-520 digunakan?

CBM eL-520 adalah detektor kebocoran gas refrigeran yang digunakan untuk menemukan kebocoran pada sistem AC dan refrigerasi. Alat ini mendeteksi refrigeran seperti R134A, R22, R32, R410A, dan lainnya dengan sensitivitas < 3 g/tahun, sesuai standar SAE J1627.

Apa spesifikasi CBM eL-520?

Spesifikasi CBM eL-520 meliputi: sensitivitas < 3 g/tahun, probe 300 mm, respons instan, baterai 2 x 1,5V AA Alkaline dengan daya tahan 40 jam, dan masa pakai sensor sekitar 30 jam. Alat ini mendeteksi R134A, R12, R22, R32, R1234yf, R404A, R408A, R409A, dan R410A.

Di mana beli CBM eL-520 di Indonesia?

Anda dapat membeli CBM eL-520 melalui 3G Electric, distributor resmi yang memasok dan mengirimkan peralatan industri ke seluruh Indonesia. Kami menangani logistik dan bea cukai untuk memastikan produk sampai ke lokasi Anda.

Bagaimana cara menggunakan CBM eL-520?

Tekan tombol untuk menyalakan unit. LED akan berkedip oranye lalu hijau. Untuk mereset ke level refrigeran sekitar, tekan dan lepaskan tombol. Untuk sensitivitas tinggi (< 3 g/tahun), klik dua kali tombol. Gunakan mode ini hanya untuk mencari kebocoran kecil.

Refrigeran apa saja yang dideteksi CBM eL-520?

CBM eL-520 mendeteksi semua refrigeran HFC, CFC, dan HCFC termasuk R134A, R12, R22, R32, R1234yf, serta campuran seperti R404A, R408A, R409A, dan R410A. Alat ini tidak boleh digunakan pada sistem dengan refrigeran mudah terbakar seperti Propana atau Isobutana.

Digunakan dalam

Aplikasi umum untuk CBM
Industrial boilers — CBM circulation pumps (mod. CM 30W) and solenoid valves (ELV series) for heating-loop control and pump staging.
Burner systems — CBM oil nozzles (FLU atomizer types), electrodes (ELC 200 mm), and solenoid coils (ELV 230V AC) for combustion ignition and flame supervision.
Plant maintenance and retrofit — CBM cable glands (CLI M25), motor couplings (ACC type D), and small-radius fittings (RAC 90°) for equipment reconfiguration and sensor integration.
Boiler water treatment — CBM chlorine test kits (DET free+combined) for feedwater and circulating-water quality monitoring in closed-loop systems.
Pump and motor assembly — CBM couplings, fittings, and cable glands for assembly and rewinding of industrial motors, circulation pumps, and auxiliary equipment.

CBM Produk

3G Electric memasok CBM hvac & refrigeration. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Pembakar & Pembakaran Pompa & Kompresor Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
Refrigerant gas detector RLD-382P
CBM
Refrigerant gas detector RLD-382P
CBM
CBM
CO2 detector EL720
Combustible gas detector EL320
CBM
Combustible gas detector EL320
CBM
CBM
Replacement cell for CLI20240 detector
CBM
CBM
Cell for EL520
CBM
CBM
Refractometer

Lainnya dari CBM

Lihat semua CBM suku cadang
Shock absorber support 700
CBM
Shock absorber support 700
CBM
CBM
Black coupling 80mm
CBM
CBM
Tube cutter 1/8 - 3/4
CBM
CBM
Vacuum pump pressure gauge vertical
CBM
CBM
Cable gland M20 for proximity switch
CBM
CBM
Set of 4 extensions 130 mm
CBM
CBM
71L/min battery vacuum pump
CBM
CBM
Black vertical right angle 80mm