Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

Gambar tidak tersedia
CBMHVAC & Refrigeration

CBM CO2 detector EL720

CBM AccuTools™ eL-720 adalah detektor kebocoran gas karbon dioksida (CO2) yang dirancang untuk aplikasi pendingin udara dan sistem HVAC. Alat ini memiliki waktu respons kurang dari 1 detik, sensitivitas tinggi < 400…

SKU 3G-CBM-01083

Juga terdaftar sebagai: CLI 20206 · CLI-20206

Merek
CBM
Item
CO2 detector EL720
Kategori
HVAC & Refrigeration
UNSPSC
40101701 — Air conditioners
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

CBM
batteries
4 x 1.5V AA Alkaline
response time
< 1 second
probe length mm
300
sensitivity low
< 4,000 ppm at 350 ppm ambient
sensitivity high
< 400 ppm at 350 ppm ambient
battery life hours
20

Konten Lembar Data

eL-720 3G-CBM-01083 Carbon Dioxide Gas Leak Detector User’s Guide eL-720 User’s Guide Congratulations on the purchase of the AccuTools™ eL-720 Carbon Dioxide Gas Leak Detector, the most technologically advanced instrument of its kind. The eL-720’s minimal power requirements, small size and high sensitivity combine to create a tool which is easy to handle and ultra effective at locating even the most difficult-to-find leaks. Please read this entire manual prior to operation to ensure trouble-free use of the eL-720. TECHNICAL DATA Dimensions 8” x 2.5” x 2.25” (20.3 cm x 6.3 cm x 5.7 cm) Weight 15 oz. (425 grams) with Batteries Batteries 4 x 1.5V 'AA' Alkaline Batteries (6 VDC) Battery Life 20 hours Sensitivity (High) < 400 ppm at 350 ppm ambient Sensitivity (Low) < 4,000 ppm at 350 ppm ambient Sensor lifetime > 2 years Operating temperature 32 – 122°F (0 – 50°C) Warm up time 10 sec. Response time < 1 second Reset time < 1 second Probe length 12” (30 cm) 1 eL-720 User’s Guide WARNING: The eL-720 contains an optical sensor that must remain free of moisture and debris. Failure to operate the unit without a filter may cause the sensor to become contaminated. This will result in a sensor malfunction as indicated by the failed sensor alarm. INSTRUCTIONS 1. Press the button to turn the unit on. Unit will beep 3 times and all LEDs will light. 2. The unit will warm up and self-calibrate for 10 seconds, after which a constant beeping will be heard. 3. Test the unit by exhaling gently into the probe tip. Human breath contains enough CO2 to cause a full-scale alarm in High Sensitivity. 4. Unit turns on in the high sensitivity level (400 ppm). For zeroing into large leaks, change to the low sensitivity level: Press the button twice (double-click like a computer mouse). The LEDs will scan from right to left and a sweeping sound effect of high to low pitch will be heard. The sensitivity is now set for 4,000 ppm. 5. Double click again to change back to high sensitivity. The LEDs will scan from left to right and a sweeping sound effect of low to high pitch will be heard. 6. To reset the unit to the ambient level of carbon dioxide, press and release the button. The LEDs will flash briefly to indicate the reset. All levels of carbon dioxide less than the reset level will be ignored. 7. Move the probe towards a suspected CO2 leak at a rate of less than 2 inches (50 mm) per second, no more than ¼ inch (5 mm) away from the suspected source. 8. If a leak exists, the sound will increase in rate and pitch and the LEDs will indicate the relative leak rate. 9. To turn the eL-720 off, press and hold the button for 1 second. 10. To conserve battery power, the eL-720 will automatically turn itself off after 10 minutes of inactivity. 2 eL-720 User’s Guide PROBE FILTER The probe filter prevents dust and moisture from contaminating the optical characteristics of the sensor. It should be replaced periodically. Occasionally, the filter may become obstructed with dirt, dust, or moisture. To determine if air is flowing properly into the eL-720 sensor, gently exhale near the probe tip. The human breath contains enough CO2 to cause a full alarm in high sensitivity mode. If the unit does not alarm, replace the filter. If the filter has become moist due to exposure to water or condensation follow this procedure to prevent moisture from contaminating the sensor: 1. Using a paper towel or shop rag, dry any moisture at the probe tip prior to unscrewing the probe tip cap. 2. Unscrew the probe tip cap to expose the filter. 3. With a paper towel or shop rag, soak up any excess moisture that may have collected on the filter and filter holder prior to removing the filter. Also thoroughly dry both inside and outside of the probe cap. 4. Remove and discard the old filter, and replace with a new one. 5. Reassemble the probe tip cap. The unit is now ready for operation. Failure to dry the filter parts as described above may result in further contamination of the new filter, and the possibility of residual moisture being drawn into the optical sensor, causing a failed sensor alarm. If moisture is suspected of being drawn into the sensor, clean the probe and sensor as described on page 4. 3 eL-720 User’s Guide SENSOR An eL-720 sensor is designed for a long, trouble-free life. The sensor is tested and calibrated automatically each time the unit is powered on. A failed or failing sensor will be indicated 3 seconds after power-on by a two-tone alarm and all LEDs flashing. CLEANING THE SENSOR If moisture is suspected of contaminating the sensor, the probe and sensor may be cleaned using this procedure. 1. IMPORTANT: Remove the sensor from the instrument as directed on page 5. 2. Remove the probe tip cap and filter from the probe tip. 3. Blow compressed air into the probe tip to remove any residual moisture from the probe. 4. Blow compressed air* into the inlet and outlet ports of the sensor. 5. Place a few drops of distilled water or isopropyl alcohol into both the inlet and outlet ports of the sensor. 6. Blow compressed air* into the inlet and outlet ports of the sensor to remove any remaining liquid and thoroughly dry the exterior of the sensor. 7. Install the sensor, and insert a new filter into probe tip. The unit should now operate properly. * Note: Do not exceed 50 psi pressure. Doing so may result in the loss of the small o-rings in the inlet and outlet ports of the sensor. 4 eL-720 User’s Guide SENSOR REPLACEMENT In the event of a failed sensor (as indicated by the Failed Sensor Alarm), cleaning or replacement of the sensor is necessary. First, clean the sensor as directed on page 4. If an alarm is still heard, the sensor must be replaced. To replace the sensor: 1. Turn the power off. 2. Remove the sensor compartment cover by loosening the sensor compartment cover screw. 3. Remove the 2 screws holding the sensor in place with a 1.5 mm hex wrench. 4. Grasp the old sensor with your fingers near the screw holes and firmly lift out of the sensor compartment. 5. Firmly press the new sensor into the compartment, noting alignment of the sensor connector tab and gas ports of the sensor with the mating features in the instrument. 6. Firmly tighten sensor in place with 2 screws and 1.5 mm hex wrench. 7. Replace and fasten sensor compartment cover. Replacement Sensor Kit Part Number ELS-7CO2 5 eL-720 User’s Guide BATTERIES Ÿ The left-most (blinking) LED indicates the battery life, and dims when the batteries approach end of life. Less than one hour of battery life remains when the LED is completely dark. • When the batteries no longer contain enough energy to power the instrument reliably, a five second tone will be heard, after which the eL-720 will power itself off. Ÿ If the unit is left on unattended, it will automatically turn off after about 10 minutes to conserve batteries. BATTERY INSTALLATION AND REPLACEMENT 1. Turn the power off. 2. Remove the battery cover from the back of the instrument by loosening the battery cover screw and lifting the battery cover off. 3. Insert 4 size ‘AA’ alkaline batteries, observing proper battery polarity. 4. Replace battery cover and tighten battery cover screw. MAINTENANCE The eL-720 should provide years of service with little maintenance aside from changing batteries, filters, and sensors. The case may be cleaned with a shop towel moistened with water and a mild detergent. Do not use solvent of any kind. 6 Declaration of Conformity in accordance with Council Directive 2004/106/EC-EMC Directive We, Manufacturer/Importer Company Name: CORE ENTERPRISES, INC. Company Address: 3650 CORAL RIDGE DR., SUITE 101 CORAL SPRINGS, FL 33065 U.S.A. Trade Name: ACCUTOOLS declare that the product Product Name: CO2 GAS LEAK DETECTOR Model Number: eL-720 Comment Issues: --- is in conformity with EMC requirements on the basis of EN 61326-1:1997+A1:1998+A2:2001+A3:2003 IEC 61000-4 Series Manufacturer/Importer oy Signature: Ci. ag = Date: December 24, 2007 Name: Cornel Opris
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

CBM Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

CBM AccuTools™ eL-720 adalah detektor kebocoran gas karbon dioksida (CO2) yang dirancang untuk aplikasi pendingin udara dan sistem HVAC. Alat ini memiliki waktu respons kurang dari 1 detik, sensitivitas tinggi < 400 ppm pada ambient 350 ppm, dan sensitivitas rendah < 4.000 ppm pada ambient 350 ppm. Dilengkapi probe sepanjang 300 mm dan ditenagai oleh 4 baterai AA 1,5V dengan daya tahan hingga 20 jam. Cari detektor CO2 untuk AC? eL-720 adalah pilihan tepat untuk mendeteksi kebocoran CO2 secara akurat.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Untuk apa CBM eL-720 digunakan?

CBM AccuTools™ eL-720 adalah detektor kebocoran gas karbon dioksida (CO2) yang digunakan untuk mendeteksi kebocoran pada sistem pendingin udara, HVAC, dan aplikasi refrigerasi. Alat ini memiliki sensitivitas tinggi < 400 ppm dan sensitivitas rendah < 4.000 ppm pada ambient 350 ppm, dengan waktu respons kurang dari 1 detik.

Apa spesifikasi baterai dan daya tahan CBM eL-720?

CBM eL-720 menggunakan 4 baterai AA Alkaline 1,5V (total 6 VDC) dengan daya tahan baterai hingga 20 jam. Spesifikasi ini memastikan alat dapat digunakan dalam waktu lama tanpa sering mengganti baterai, cocok untuk pekerjaan lapangan di industri.

Bagaimana cara mengganti sensitivitas pada CBM eL-720?

Untuk mengganti sensitivitas, tekan tombol dua kali (double-click). Saat menyala, alat berada di sensitivitas tinggi (< 400 ppm). Double-click akan mengubah ke sensitivitas rendah (< 4.000 ppm) yang ditandai dengan LED menyapu dari kanan ke kiri dan efek suara. Double-click lagi untuk kembali ke sensitivitas tinggi.

Di mana beli CBM eL-720 di Indonesia?

Anda dapat membeli CBM AccuTools™ eL-720 melalui 3G Electric, distributor resmi yang memasok dan mengirimkan peralatan industri ke seluruh Indonesia. Kami menangani logistik dan kepabeanan untuk memastikan produk sampai ke lokasi Anda. Hubungi kami untuk minta penawaran.

Berapa panjang probe CBM eL-720?

CBM eL-720 dilengkapi probe fleksibel sepanjang 300 mm (12 inci). Panjang probe ini memudahkan akses ke area sempit atau sulit dijangkau pada sistem pendingin udara dan perpipaan CO2, sehingga deteksi kebocoran lebih efektif.

Digunakan dalam

Aplikasi umum untuk CBM
Industrial boilers — CBM circulation pumps (mod. CM 30W) and solenoid valves (ELV series) for heating-loop control and pump staging.
Burner systems — CBM oil nozzles (FLU atomizer types), electrodes (ELC 200 mm), and solenoid coils (ELV 230V AC) for combustion ignition and flame supervision.
Plant maintenance and retrofit — CBM cable glands (CLI M25), motor couplings (ACC type D), and small-radius fittings (RAC 90°) for equipment reconfiguration and sensor integration.
Boiler water treatment — CBM chlorine test kits (DET free+combined) for feedwater and circulating-water quality monitoring in closed-loop systems.
Pump and motor assembly — CBM couplings, fittings, and cable glands for assembly and rewinding of industrial motors, circulation pumps, and auxiliary equipment.

CBM Produk

3G Electric memasok CBM hvac & refrigeration. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Pembakar & Pembakaran Pompa & Kompresor Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
Refrigerant gas detector EL520
CBM
Refrigerant gas detector EL520
Combustible gas detector EL320
CBM
Combustible gas detector EL320
Refrigerant gas detector RLD-382P
CBM
Refrigerant gas detector RLD-382P
CBM
CBM
Replacement cell for CLI20240 detector
CBM
CBM
Cell kit for EL720
CBM
CBM
Cell for EL520

Lainnya dari CBM

Lihat semua CBM suku cadang
Shock absorber support 700
CBM
Shock absorber support 700
CBM
CBM
Black coupling 80mm
CBM
CBM
Tube cutter 1/8 - 3/4
CBM
CBM
Vacuum pump pressure gauge vertical
CBM
CBM
Cable gland M20 for proximity switch
CBM
CBM
Set of 4 extensions 130 mm
CBM
CBM
71L/min battery vacuum pump
CBM
CBM
Black vertical right angle 80mm