Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

Supco Megohmmeter - HVAC Equipment
SupcoHVAC Equipment

Supco Megohmmeter

Supco M500 Megohmmeter adalah alat uji isolasi listrik yang dirancang khusus untuk teknisi HVAC dan peralatan industri. Dengan tegangan terapan 500 volt dan rentang pengukuran 20 hingga 1000 Megohms, alat ini sangat…

SKU 3G-CBM-01287

Juga terdaftar sebagai: COP 14004 · COP-14004

Merek
Supco
Item
Megohmmeter
Kategori
HVAC Equipment
UNSPSC
40101709 — Air handling unit
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

Supco
model
M500 Insulation Tester
display
LEDs
power source
2 C-size batteries
applied voltage
500 volts
dimensions inches
3-3/8" x 6-3/8" x 1-3/4"
measurement range
20 to 1000 Megohms

Konten Lembar Data

HARD STARTING AND OVERLOAD PROBLEMS: SPECIFICATIONS Range 20 to 1000 MegOhms M500 MEGOHMMETER Applied Voltage 500 Volts Answering a call where the problem is a hard-starting Power Source (2) “C” Size Batteries condition is more involved than merely replacing a Test Leads (2) 9” Long (Store within case) defective relay, start capacitor, or installing a hard start. The unknown factor is how long did the unit cycle on the overload before the consumer realized the food compartment was getting warm and called OPERATION the service dispatcher. In other words, was the wind- 1. Install two new alkaline “C” size batteries. Polarity is ing overheated to a point that could have damaged indicated on bottom of battery compartment. the insulation? This unknown factor of overheated 2. Remove ALL wires that are connected to the terminals windings is also present on calls that relate to dirt- that are to be tested. Attach one test lead from the meg- clogged condensers, defective condenser fan bearings Ohmmeter to ANY WINDING TERMINAL and the other test or motors and brownouts. Whenever a sustained motor lead to the METAL CASE of the motor. Make sure the point of overload condition existed before you arrived on the contact is clean to the BARE METAL (no paint). job site, a megOhmmeter test tells both you and the 3. Depress “POWER” button, wait approximately 10 seconds consumer if there was any damage to the winding then proceed to read the insulation value shown on the cor- insulation. Putting this information on the consumer’s responding illuminated LED lamp. receipt and recording it in the office records is sound 4. Illuminated “BELOW 20” lamp indicates low insulation or a business practice for any future problems and assures short circuit in the unit being tested. the customer that the service engineer “KNOWS HIS 5. If the “ON” lamp is illuminated but no light appears on the BUSINESS”. megOhm scale, then the insulation value is MORE THAN 1000 MEGOHMS. APPLICATION 6. If the “ON” light is not illuminated when the “POWER” button is depressed, then the batteries are installed improp- Hermetic Refrigeration Motors erly or the batteries are weak and should be replaced. 7. Remember, all tests are made from the motor Hermetic motors require special test parameters since TERMINAL to the METAL CASE. the winding operates in an oil and refrigerant atmo- sphere. Under normal conditions the oil and refriger- ant have a high electrical resistance. However, when Why All HVAC/R they are contaminated with moisture, the electrical resistance changes and a low megOhm reading of the winding terminal to ground may actually be the resistance of the contaminants in the oil and not in the winding insulation. New hermetic motors have a Service Technicians resistance value of more than 100 megOhms. Readings of 50 megOhms or less would indicate that either the Need This Instrument winding insulation is deteriorating or the oil/refrig- erant is contaminated. Installing an oversized drier may clean up the system or another possible solution could be replacing all the compressor oil. In either You have often heard the expression, “THE MOTOR case, if the megOhm tests show even the slightest IS BURNT OUT” or “THE MOTOR IS HALF COOKED” improvement in resistance values, the remedy may or “IT WAS OVERHEATED”. Actually, the reference is have checked a declining condition. A good “rule of F583 being made to the condition of the motor winding thumb” is to smell a small sample of the oil. If at any 09092015 insulation... time in the history of the unit the motor was severely overloaded, it will leave a tell-tale trace in the oil that can never be removed other than by discharging SEALED UNIT PARTS CO., INC. all refrigerant and replacing oil. The odor of burnt PO Box 21, 2230 Landmark Place insulation is easily recognized and a low resistance Allenwood, NJ 08720 USA value of 20 megOhms or less will verify that the motor www.supco.com insulation may be severely damaged. www.supco.com The wire itself is rarely, if ever, destroyed. It is always 100-200 MegOhms 20-60 MegOhms the motor-winding insulation that determines if the motor Readings Readings is good, bad, or on the verge of becoming bad. The winding insulation prevents the current, which is going through the Most electrical engineers and motor designers agree A 0 to 60 megOhms reading in a hermetic compres- wire, from traveling into the motor body. The expression, that a measurement of 150 or more megOhms across sor is an indication that you can have any one of “THAT MOTOR IS GROUNDED” simply means that the insula- an electrical terminal to its ground would be consid- a few problems; a winding that was overheated, tion of the winding has deteriorated or has become damaged ered excellent insulation, and a reading of 100 to 150 contaminated oil, or moisture circulating in the from heat and can no longer resist the current from traveling megOhms is very good. system. Sampling the oil for a burning odor will tell into the motor body. You can TEST the resistance of the insu- you immediately that the winding was overheated. lation, or you can MEASURE the resistance of the insulation. If the oil is clean and odor free, it can still have some contamination that is causing the low megOhm THERE ARE TWO WAYS OF reading. A 20 megOhm reading shows severe contam- ination and failure of the system is likely. The best TESTING THE INSULATION: overall protective procedure is to dump and replace all the oil and change and install a new liquid line 1. A high voltage test from wire to ground (motor body). 2. A high voltage breakdown test from wire to ground. A drier. If the oil had an odor, a thorough check of the high voltage test is usually performed at the factory where condensing medium, air fans, cooling tower and all the product is manufactured. The Underwriters Labora- motors for worn bearings should be made. Now that tory standard is to test an electrical product from wire you have discovered a low megOhm reading and have to ground with a voltage equal to 1,000 plus twice the taken the necessary preventative measures, the operating voltage, as an example: If a motor was operating follow-up is very important. Take another reading in at 115VAC, you would conduct the test at 230VAC from wire a few weeks, and if the reading remains the same to ground and measure if there was any current going into or improves, take another measurement in a few the body. A high voltage breakdown test is performed to months. If the reading shows more deterioration, determine at what voltage point the insulation will break you can forewarn the owner that there is going to down and allow current to pass into the motor body. Since be a major breakdown in their system. One of the you are actually destroying the insulation, a breakdown test 60-100 MegOhms best maintenance programs for a new system is to log the megOhmmeter readings when the unit is first is usually performed in a laboratory where different insula- tions are being tested for their resistance to high voltage, Readings installed and compare the readings every six months. or a more technical term, dielectric strength. The two Measurements of 60 to 100 megOhms would show a above methods are used to TEST the insulation resistance. decline in the insulation resistance, either in an area or a specific spot. This is a most important measure- MEASURING THE ment. It tells you that if you do not take corrective steps, the insulation will completely breakdown. INSULATION RESISTANCE: With open type motors it is a matter of good house- keeping by cleaning the dust and any grime from the Since the measurement of electrical resistance is the OHM, windings, using a recommended solvent. we use an Ohmmeter. When measuring the insulation re- sistance of a motor winding, we are involved in resistances in the range of 50 to 100 million ohms. As…
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

Supco Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

Supco M500 Megohmmeter adalah alat uji isolasi listrik yang dirancang khusus untuk teknisi HVAC dan peralatan industri. Dengan tegangan terapan 500 volt dan rentang pengukuran 20 hingga 1000 Megohms, alat ini sangat berguna untuk mendiagnosis kerusakan isolasi belitan motor akibat panas berlebih. Megohmmeter ini ditenagai oleh 2 baterai ukuran C dan memiliki dimensi ringkas 3-3/8" x 6-3/8" x 1-3/4", menjadikannya solusi praktis untuk mengecek kondisi isolasi motor di lapangan.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Apa fungsi Megohmmeter Supco M500?

Megohmmeter Supco M500 berfungsi untuk mengukur resistansi isolasi belitan motor, terutama setelah terjadi kondisi kelebihan beban (overload) yang berkepanjangan. Alat ini membantu teknisi mengetahui apakah isolasi belitan telah rusak akibat panas berlebih, sehingga dapat mencegah kerusakan lebih lanjut pada peralatan.

Apa spesifikasi teknis Supco M500 Insulation Tester?

Spesifikasi Supco M500 meliputi tegangan terapan 500 volt, rentang pengukuran 20 hingga 1000 Megohms, dan menggunakan 2 baterai ukuran C sebagai sumber daya. Dimensi alat ini adalah 3-3/8" x 6-3/8" x 1-3/4" dan dilengkapi dengan dua kabel uji sepanjang 9 inci yang tersimpan di dalam casing.

Bagaimana cara menggunakan Megohmmeter Supco M500?

Lepaskan semua kabel dari terminal yang akan diuji. Hubungkan satu kabel uji ke terminal belitan motor dan kabel lainnya ke badan motor (logam tanpa cat). Tekan tombol 'POWER' dan tunggu sekitar 10 detik. Baca nilai isolasi dari lampu LED yang menyala. Lampu 'BELOW 20' menandakan isolasi rendah atau korsleting.

Di mana beli Supco M500 Megohmmeter di Indonesia?

Anda dapat membeli Supco M500 Megohmmeter melalui 3G Electric, distributor resmi yang memasok dan mengirimkan peralatan industri ini ke seluruh Indonesia. Kami menangani logistik dan kepabeanan untuk memastikan produk sampai ke lokasi Anda dengan aman dan tepat waktu.

Digunakan dalam

Aplikasi umum untuk Supco
Commercial refrigeration display cases — Supco RO82 relay and CSS-25U starter for compressor motor control without run capacitors
Medium-load HVAC systems — Supco SPP 6/SPP 8 hard-start devices to reduce compressor inrush current and extend motor lifespan
Cold-chain pharmaceutical and food storage — SL300TH temperature–humidity data logger for continuous monitoring and regulatory documentation
Refrigerant service operations — Piercing valves and perforator cocks in 1/2" and 5/8" sizes for fast, non-invasive line access
Compressor thermal management — Universal Compressor Door for reducing shell temperature and improving efficiency in hot ambient conditions
Retrofit and field repairs — Supco controls with Quick Connect terminals for rapid installation in legacy refrigeration circuits

Supco Produk

3G Electric memasok Supco hvac equipment. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Pembakar & Pembakaran Pompa & Kompresor Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
Supco
Supco
Digital impedance tester
Electronic manometer DDM55
Supco
Electronic manometer DDM55
Differential thermometer
Supco
Differential thermometer
Thermometer and humidity
Supco
Thermometer and humidity
Sound level meter
Supco
Sound level meter
Thermometer and anemometer
Supco
Thermometer and anemometer

Lainnya dari Supco

Lihat semua Supco suku cadang
Supco
Supco
Axial fan motor D.350 380V THREE-PHASE
CSS-32U 32A starting module
Supco
CSS-32U 32A starting module
Supco
Supco
Axial fan motor D.350 230V single phase with square plate
Supco
Supco
Axial fan motor D.500 380V three-phase with square plate
Supco
Supco
Axial fan motor D.630 230V single-phase with square plate
Supco
Supco
Axial fan motor D.300 380V 3-PHASE
Supco
Supco
Telescopic thermometer -50..+300°C L.max:914mm
Supco
Supco
Axial fan motor D.400 230V single-phase with square plate