Honeywell Housing S4560 C 1053 U - Controls
HoneywellControls

Honeywell Housing S4560 C 1053 U

Honeywell S4560 C 1053 U adalah kontrol pengapian otomatis yang dirancang untuk pembakar industri sesuai standar EN 298. Perangkat ini beroperasi pada tegangan 220–240 V, 50 Hz dengan konsumsi daya maksimal 10 VA…

SKU 3G-CBM-04231

Juga terdaftar sebagai: HON 07408 · HON-07408

Merek
Honeywell
Item
Housing S4560 C 1053 U
Kategori
Controls
UNSPSC
39121026 — Control power transformer
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

Honeywell
model
S4560
voltage
220–240 V, 50 Hz
waiting time
0–24 s
max spark gap
3.5 mm
prepurge time
0–24 s
min flame current
0.7 µA
relative humidity
90% max at 40 °C
max output current
3 A
ambient temperature range
0–60 °C

Konten Lembar Data

S4560 AUTOMATIC IGNITION CONTROL INSTRUCTION SHEET Dimensions See fig. 2. Ambient temperature 0 ... 60 _C Relative humidity 90% max. at 40 _C (non condensing) Supply voltage Line voltage, 220 V (--15%) ... 240 V (+10%), 50 Hz (± 2 Hz) Power consumption 10 VA max. Electrical rating Valve(s) output: 1 A max cos ♥ > 0.6 Fan output (Suffix C,D,R and T): 1 A max cos ♥ > 0.6 Alarm output: 1 A max cos ♥ > 0.6 Flame indication relay: 1 A max cos ♥ >= 0.6 APPLICATION External ignition transformer: 1 A max cos ♥ > 0.6 All outputs together: 3 A (max) The S4560 provides automatic ignition and control for burners Electrical connection in accordance with EN 298. High tension spark: 2.8 x 0.5 mm spade terminal. Flame rod and ground: 6.3 x 0.8 mm or 4.8 x 0.8 mm spade SPECIFICATIONS terminal (depending on O.S. number) Multiple connector: Molex 3001 series Model Timing (depending on O.S. number) S4560: 220 ... 240 V, 50 Hz. Waiting time (Tw)/Prepurge time (Tp): 0 ... 24 s Suffix A: For atmospheric burners. Non volatile lock out in Safety time (Ts): 0 ... 250 s accordance with EN 298 Stabilization time (Tstab): 0 ... 15 s Suffix B: As suffix A except a built in flame indication relay for modulating applications. Flame sensing Suffix C: For fan assisted applications. Non volatile lock out in Flame sensing is based on the rectification principle. accordance with EN 298 Minimum flame current: 0.7 ←A Subject to change without notice. Printed in the Netherlands. Suffix D: As suffix C except a built in flame indication relay for Response time ”ON”: < 200 ms (at 2 ←A flame current) modulating applications. Response time ”OFF”: < 1 s Suffix E: As suffix A except lock--out after flame lost during Maximum cable length: 1 m normal operation. Not protected against electrical shock. Suffix P: As suffix A except volatile lock out, reset by interrupting heat demand. Ignition Suffix Q: As suffix B except volatile lock, reset by interrupting Integral electronic spark generator heat demand. Spark voltage: 12 kV at 40 pF load Suffix R: As suffix C except volatile lock out, reset by Repetition rate: 12 Hz interrupting heat demand. Maximum cable length: 1 m Suffix T: As suffix D except volatile lock out, reset by Not protected against electrical shock. interrupting heat demand. EN1R--9086 0009R4--NE Fusing If air flow is not proven by air proving switch, automatic Automatic ignition control should be externally fused to ignition control will remain in a waiting mode with fan prevent damage to automatic ignition control, wiring or energized. periferals. If flame is lost during normal run, the automatic ignition control External fuse: 16 A slow max. repeats start sequence. Enclosure IP 00 WARNING Recommended flame sensor If fan/air proving switch response time is  1 s, an Q375 Spark igniter or flame sensing electrode orifice in the air flow switch tube must be mounted in Q354 Flame sensor order to avoid cycling. Accessories (to be ordered separately) lock- out reset Multiple connectors including 1 m leads, order number: The auto ignition control will be reset by either depressing the 3 pole (suffix B, C, Q and R): . . . . . . . . . . . . . 45.900.419--002 internal or the external reset button in the external wiring 5 pole(suffix A, B, C, D and E ): . . . . . . . . . . . 45.900.419--003 (suffix A, B, C, D and E) or by interrupting the power supply 6 pole (suffix D and T): . . . . . . . . . . . . . . . . . . 45.900.419--004 (suffix P, Q, R and T). High voltage cable (500 mm): . . . . . . . . . . . . 45.900.411--001 If a first reset is not succesful wait at least 15 seconds before making another reset. SYSTEM OPERATION INSTALLATION AND CHECKOUT IMPORTANT The automatic ignition controls S4560P, Q, R, IMPORTANT and T do not have an independant manual reset function. The application of these types is therefore Installer must be a trained experienced service man. restricted to only those applications where resetting Disconnect power supply to prevent electrical shock by switching off the heat demand is allowed. and/or equipment damage. Automatic ignition control for atmospheric appliances Before installing or replacing any control check that See fig. 5. and 6. for suffix A, B, P and Q and fig 7. for suffix E type number is correct for the application. Never use When there is a call for heat, a waiting period (Tw) elapses a type with a larger safety time for which the before built--in or external igniter and gas valve is switched appliance is approved. on. The appliance manufacturer’s instructions should Ignition spark ignites gas and resulting flame is detected by always be followed when provided. If such the flame rod. instructions are not provided see fig. 11. ... 19. for Internal ignition is switched off immediately after flame is typical systems. established and --if appropiate-- external ignition is switched off after elaps of stabilisation time. Ensure combustion chamber is free of gas before If flame is not established within the safety time (Ts), the start up. automatic ignition control locks--out. Conduct a thorough check out when installation is If flame is lost during normal run, the automatic ignition control completed. repeats start sequence (except suffix E). In case of ignition control with LPG valve connection, gas At the first start the automatic ignition control can be pressure…
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

Honeywell Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

Honeywell S4560 C 1053 U adalah kontrol pengapian otomatis yang dirancang untuk pembakar industri sesuai standar EN 298. Perangkat ini beroperasi pada tegangan 220–240 V, 50 Hz dengan konsumsi daya maksimal 10 VA. Dilengkapi waktu tunggu dan prepurge yang dapat diatur 0–24 detik, serta arus nyala api minimum 0,7 µA. Housing ini mendukung output katup, kipas, dan alarm masing-masing hingga 1 A, dengan total output maksimal 3 A, cocok untuk aplikasi pembakar dengan kipas (suffix C).

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Apa fungsi Honeywell S4560 C 1053 U?

Honeywell S4560 C 1053 U berfungsi sebagai kontrol pengapian otomatis untuk pembakar industri, khususnya tipe fan assisted (suffix C). Perangkat ini mengatur urutan pengapian, prepurge, dan pengamanan nyala api sesuai standar EN 298, dengan tegangan 220–240 V, 50 Hz.

Apa spesifikasi teknis Honeywell S4560 C 1053 U?

Spesifikasi teknis meliputi tegangan 220–240 V, 50 Hz, konsumsi daya 10 VA, waktu tunggu dan prepurge 0–24 detik, arus nyala api minimum 0,7 µA, suhu lingkungan 0–60 °C, kelembaban relatif maksimal 90% pada 40 °C, dan output total maksimal 3 A.

Di mana beli Honeywell S4560 C 1053 U di Indonesia?

Anda dapat membeli Honeywell S4560 C 1053 U melalui 3G Electric, distributor resmi yang memasok dan mengirimkan peralatan industri ke seluruh Indonesia. Kami menangani logistik dan bea cukai untuk memastikan produk sampai ke lokasi Anda.

Bagaimana cara memilih Honeywell S4560 yang tepat?

Pilih Honeywell S4560 berdasarkan suffix yang sesuai: suffix C untuk pembakar dengan kipas (fan assisted) seperti model C 1053 U. Pastikan tegangan 220–240 V, 50 Hz, dan waktu tunggu/prepurge 0–24 detik sesuai kebutuhan aplikasi Anda.

Apa perbedaan Honeywell S4560 suffix C dengan suffix lainnya?

Suffix C pada Honeywell S4560 dirancang untuk pembakar fan assisted dengan lock out non-volatile sesuai EN 298, berbeda dengan suffix A untuk pembakar atmosferik. Suffix C memiliki output kipas 1 A dan cocok untuk aplikasi yang memerlukan prepurge dengan kipas.

Digunakan dalam

Aplikasi umum untuk Honeywell
Commercial kitchen and inflight-catering steam boilers — RM7890 / RM7895 flame relays with UV detection
Food-processing ramp-and-dwell ovens — DBC2000E / DBC2100E controllers
Hotel and hospital boiler plants — VR8205 combination gas controls
Petrochemical tank-farm heating — V4xxx gas-valve bodies with ML7420 actuators
Retrofit swap-outs from legacy Fireye / Satronic — Honeywell replacement kits

Honeywell Produk

3G Electric memasok Honeywell controls. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Pembakar & Pembakaran Pompa & Kompresor Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
Honeywell
Honeywell
Housing S4565 CF 1052 U
Housing S4565 BF 1161 U
Honeywell
Housing S4565 BF 1161 U
Honeywell
Honeywell
Housing S4565 BF 1021 U
Housing S4965 B 3007 U
Honeywell
Housing S4965 B 3007 U
S4570 LS 1059 U housing
Honeywell
S4570 LS 1059 U housing
S4565 BF 1112 U housing
Honeywell
S4565 BF 1112 U housing

Lainnya dari Honeywell

Lihat semua Honeywell suku cadang
Box S4565 C 1025 V01U
Honeywell
Box S4565 C 1025 V01U
Housing S4565 A 2050 U
Honeywell
Housing S4565 A 2050 U
Housing S4565 BF 1062 U
Honeywell
Housing S4565 BF 1062 U
Honeywell
Honeywell
ST7800 A 1013 prepurge
Honeywell
Honeywell
Pressure switch DWR1 0.2/1.6 bar
Honeywell
Honeywell
Prepurge ST7800 A 1005
Honeywell
Honeywell
KT COMB 50 (pair of flanges)
Honeywell
Honeywell
Pressure switch DWR6 0.5/6 bar