Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

Gambar tidak tersedia
HoneywellControls

Honeywell Housing S4565 BF 1021 U

Housing S4565 BF 1021 U dari Honeywell adalah rumah kontrol pengapian yang dirancang untuk sistem Combined Valve and Ignition (CVI) pada ketel uap pemanas sentral domestik gas, ketel kombi, dan pemanas udara hangat…

SKU 3G-CBM-04237

Juga terdaftar sebagai: HON 07423 · HON-07423

Merek
Honeywell
Item
Housing S4565 BF 1021 U
Kategori
Controls
UNSPSC
39121026 — Control power transformer
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

Honeywell
housing rating
UL 94-V0 optional
supply voltage
220/230 - 240 V 50/60 Hz
ignition connector
AMP 2.8 x 0.5 mm
ignition frequency
2.5 - 60 Hz
flame detection connector
AMP 4.8 x 0.8 mm

Konten Lembar Data

S4565, S4575 AND S4585 IGNITION CONTROLS FOR COMBINED VALVE AND IGNITION SYSTEM PRODUCTION HANDBOOK APPLICATION The Combined Valve and Ignition (CVI) system has been developed for application in gas fired domestic central heating boilers, combi boilers and warm air furnaces or water heater appliances with an automatic ignition system. For this system, the S4565, S4575 and S4585 ignition controls are used in conjunction with the VK41.. series gas controls to provide and optimised safety sub-system for programmed safe light up and flame supervision of the main burner of the appliance The combined system then provides programmed safe light up, flame supervision and regulation of gas flow to the main burner and/or pilot burner of the appliance. NOTE: The Combined Valve and Ignition (CVI) product concept consists of a specially designed gas valve family in combination with a dedicated ignition controls family. This product handbook describes the CVI ignition controls family S4565, S4575 and S4585 for use in combination with the CVI gas control family VK41.. For details of the CVI gas controls please refer to Product Handbook EN2R-9004. For an up-to-date copy please contact your nearest Honeywell office. For glossary of terms, abbrevations and symbols see document EN2R-9039 Subject to change without notice. All rights reserved 1 EN2R-9031 0111R12-NE CONTENTS General Page Description 3 Features 4 Dimensional drawing housing 5 Dimensional drawing “old style” housing 6 Accessories for degree of protection IP 20, IP 40, IP X4, IP 44 7 Assembling of IP X4/44 housing 8 Application S4565/S4575/S4585 ignition controls 9 S4565 ignition controls Specifications S4565A, B ,P, Q 10 System operation S4565A, B, P, Q 12 Specifications S4565C, D, R, T 14 System operation S4565C, D, R, T 16 Specifications S4565AD, BD, CD, DD, PD, QD, RD, TD “1000” series 18 System operation S4565AD, BD, CD, DD, PD, QD, RD, TD “1000” series 22 Specifications S4565AD, BD, CD, DD, PD, QD, RD, SD, TD “2000” series 25 System operation S4565AD, BD, CD, DD, PD, QD, RD, SD, TD “2000” series 30 Specifications S4565AF, BF, CF, DF, PF, QF, RF, TF 33 System operation S4565AF, BF, CF, DF, EF, PF, QF, RF, TF 35 Application note S4565BF with second main valve control 38 Application note S4565DF, TF with external main burner interrupt 39 Specifications S4565PV, QV, RV, TV 42 System operation S4565PV, QV, RV, TV 45 S4575 ignition controls Specifications S4575A, B, P, Q 50 System operation S4575A, B, P, Q 52 S4585 ignition controls Specifications S4585D 54 System operation S4585D 57 Various General considerations 59 Installation EMC guidelines 60 Electrical connections and wiring 61 Quality assurance statement 62 Standards and approvals 63 Ordering information 64 Overview ignition controls 65 Replacement parts and accessories 66 Cable assemblies 66 EN2R-9031 0111R12-NE 2 DESCRIPTION Valves • S4565 The Combined Valve and Ignition (CVI) system controls and Direct Burner Ignition (DBI) or Intermittent Pilot ignition performs all the functions required for safe ignition, flame (IP) with a defined safety time for applications with or supervision and for safely regulating the gas flow to the pilot without fan, with flame detection, volatile or non volatile and/or main burner. lock out, optional remote reset, fixed waiting times and in case of flame failure recycling of the full start up The CVI consists of a gas valve of the VK41.. series and a sequence. dedicated ignition control of the series S4565, S4575 and S4585 which is connected directly on to it. • S4575 Hot Surface Ignition (HSI) with a defined safety time for Ignition control applications with or without fan, with flame detection, The S4565, S4575 or S4585 220/240 Vac series ignition volatile or non volatile lock out, optional remote reset, controls can be directly electrically connected to a VK41.. fixed waiting times and in case of flame failure recycling series gas control. of the full start up sequence. The S4565/S4575 ignition controls are not intended for direct • S4585 exposure to flame envelope. Intermittent Pilot ignition (IP) for atmospheric or fan assisted applications with the so called ”wild pilot system” S4565, S4575 and S4585 ignition controls give excellent without safety time for ignition, with flame detection on the performance and a high reliability standard. There are pilot flame. Wild pilot system means a safety Ts + ∞ and is versions available for different ignition systems: applicable for pilot burners up to 250 Watt The S4565/S4575 ignition controls are approved on the Intermittent Pilot ignition (IP) for atmospheric or fan assisted North American standard ANSI Z21.20 Automatic Ignition applications with the so called ”wild pilot system” * without Systems. safety time for ignition and flame detection on the pilot flame. S4565, S4575 and S4585 systems function in accordance The performance and the construction of the ignition control with EN 298. is optimized and dedicated to the VK41.. series gas controls. NOTE: S4565SD is not an ignition control but an ignition circuit and rectifier only 3 EN2R-9031 0111R12-NE FEATURES General Electrical connection options • All burner control safety functions concentrated in one • Connection to the gas control is made entirely by reliable and optimized system. plugging the ignition control on. • Specially designed to provide the optimum system • Electric connections are positioned on top and are made solution in gas appliances with a DBI or IP system to light by a multiple plug-in connector (IP 20 enclosure if side the main burner. connections are accessible). • Both gas control and ignition control incorporate time • The housing can receive a cover for strain relief in order proven design concepts assuring reliability. to have an IP 30 or an IP 40 enclosure,(if side • Easy assembly of ignition control on gas control by connections are accessible). When the cover is applied in plugging it on from the top. combination with the cable seal grommet, sleeves and gasket the enclosure is IP X4 (IP 44 if side connections • Mounting orientation may be within 90° in any direction are accessible) from the electric on/off operator upright position. • Ignition and flame detection connections are at the outlet Ignition control end of the housing. • Hybrid technology for high reliability. • Flame detection is accessible. • Flame supervision.…
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

Honeywell Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

Housing S4565 BF 1021 U dari Honeywell adalah rumah kontrol pengapian yang dirancang untuk sistem Combined Valve and Ignition (CVI) pada ketel uap pemanas sentral domestik gas, ketel kombi, dan pemanas udara hangat. Komponen ini mendukung tegangan suplai 220/230 - 240 V 50/60 Hz, dengan konektor pengapian AMP 2.8 x 0.5 mm dan konektor deteksi nyala api AMP 4.8 x 0.8 mm. Housing ini merupakan bagian penting dari suku cadang pembakar untuk memastikan pengapian dan pengawasan nyala api yang aman dan terprogram.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Apa fungsi Housing S4565 BF 1021 U Honeywell?

Housing S4565 BF 1021 U adalah rumah kontrol pengapian yang digunakan dalam sistem CVI (Combined Valve and Ignition) untuk ketel uap gas domestik. Fungsinya adalah menyediakan pengapian terprogram dan pengawasan nyala api pada pembakar utama atau pilot, bekerja bersama katup gas seri VK41.. dari Honeywell.

Apa spesifikasi listrik Housing S4565 BF 1021 U?

Spesifikasi listrik Housing S4565 BF 1021 U meliputi tegangan suplai 220/230 - 240 V 50/60 Hz. Konektor pengapian menggunakan tipe AMP 2.8 x 0.5 mm, dan konektor deteksi nyala api menggunakan tipe AMP 4.8 x 0.8 mm. Frekuensi pengapian berkisar antara 2.5 hingga 60 Hz.

Di mana beli Housing S4565 BF 1021 U di Indonesia?

Anda dapat membeli Housing S4565 BF 1021 U asli dari Honeywell melalui 3G Electric, distributor resmi yang melayani pengiriman ke seluruh Indonesia. Kami menangani logistik dan bea cukai untuk memastikan komponen peralatan pembakaran ini sampai ke lokasi proyek Anda dengan aman.

Apakah Housing S4565 BF 1021 U kompatibel dengan katup gas VK41..?

Ya, Housing S4565 BF 1021 U dirancang khusus untuk digunakan bersama katup gas seri VK41.. dari Honeywell dalam sistem CVI. Kombinasi ini menyediakan sub-sistem keselamatan yang dioptimalkan untuk pengapian aman dan pengaturan aliran gas ke pembakar utama atau pilot pada ketel uap dan pemanas air.

Digunakan dalam

Aplikasi umum untuk Honeywell
Commercial kitchen and inflight-catering steam boilers — RM7890 / RM7895 flame relays with UV detection
Food-processing ramp-and-dwell ovens — DBC2000E / DBC2100E controllers
Hotel and hospital boiler plants — VR8205 combination gas controls
Petrochemical tank-farm heating — V4xxx gas-valve bodies with ML7420 actuators
Retrofit swap-outs from legacy Fireye / Satronic — Honeywell replacement kits

Honeywell Produk

3G Electric memasok Honeywell controls. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Pembakar & Pembakaran Pompa & Kompresor Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
Housing S4565 BF 1161 U
Honeywell
Housing S4565 BF 1161 U
Honeywell
Honeywell
Housing S4565 CF 1052 U
Housing S4565 BF 1062 U
Honeywell
Housing S4565 BF 1062 U
S4565 BF 1112 U housing
Honeywell
S4565 BF 1112 U housing
Housing S4560 C 1053 U
Honeywell
Housing S4560 C 1053 U
Housing S4965 B 3007 U
Honeywell
Housing S4965 B 3007 U

Lainnya dari Honeywell

Lihat semua Honeywell suku cadang
Box S4565 C 1025 V01U
Honeywell
Box S4565 C 1025 V01U
Housing S4565 A 2050 U
Honeywell
Housing S4565 A 2050 U
Housing S4565 BF 1062 U
Honeywell
Housing S4565 BF 1062 U
Honeywell
Honeywell
ST7800 A 1013 prepurge
Honeywell
Honeywell
Pressure switch DWR1 0.2/1.6 bar
Honeywell
Honeywell
Prepurge ST7800 A 1005
Honeywell
Honeywell
KT COMB 50 (pair of flanges)
Honeywell
Honeywell
Pressure switch DWR6 0.5/6 bar