Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

Honeywell Base Q7800 A 1005 - Controls
HoneywellControls

Honeywell Base Q7800 A 1005

Honeywell Q7800A 1005 adalah universal wiring subbase 22-terminal yang dirancang khusus untuk EC7800 SERIES Relay Modules. Subbase ini menyediakan terminal untuk field wiring dengan knife blade terminals yang…

SKU 3G-CBM-04251

Juga terdaftar sebagai: HON 17302 · HON-17302

Merek
Honeywell
Item
Base Q7800 A 1005
Kategori
Controls
UNSPSC
39121026 — Control power transformer
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

Honeywell
enclosure
NEMA 1
terminals
22-terminal
product type
Universal wiring subbase
mounting screws
M3.5 x 0.6

Konten Lembar Data

Honeywell EC7800 SERIES Q7800A 22-Terminal Universal Wiring Subbase Application The Q7800A is a universal wiring subbase for the EC7800 SERIES Relay Modules. The universal wiring subbase provides terminais for field wiring. Knife blade terminais located on the EC7800 SERIES Relay Module engage the Q7800A bifurcated contacts to make electrical connections. The Q7800A l021 (2-sided) subbase is available for panel mounting applications. Knockouts are provided in the back, top and bottom for conduit connections. Specifications &cAUTION WEIGHT: Disconnect power supply before beginning in­ Q7800A: 196 grams. stallation to prevent electrical shock and equip­ DIMENSIONS: See Fig. l. ment damage. More than one disconnect may be ENCLOSURE: NEMA 1. involved. APPROVALS: To meet EN60730 approval the Q7800A subbase must be mounted in a secured panel which meets IP40 Follow the equipment manufacturer instructions if avail­ class of protection. able; otherwise, proceed as follows below. ACCESSORIES: Electrical Access Slot Covers, part no. 221779. MOUNTING NOTE: For installation dimensions, see Fig. l. l. Place the subbase in a location within the ambient Installation temperature rating of the EC7800 SERIES Relay Module being used. Refer to the appropriate Instructions. 2. Mount the subbase in any position except horizon­ WHEN INSTALLING TlDS PRODUCT ••• tally with the bifurcated contacts pointing down. The stan­ l. Read these instructions carefully. Failure to follow dard vertical position is recommended. them could damage the product or cause a hazardous 3. Mount the Q7800A directly in the control cabinet. condition. Be sure to allow adequate clearance for servicing, installa­ 2. Check the ratings given in the instructions and on the tion, access or removal of the EC7800 SERIES Relay product to make sure the product is · suitable for your Module, Keyboard Display Module, Runffest switch, flame application. amplifier signal voltage probes, electrical signal voltage 3. Installer must be a trained, experienced, Flame Safe­ probes and electrical field connections. guard service technician. 4. Disconnect the power supply before beginning in­ IMPORTANT: Do not mount the wiring subbase hori­ stallation to prevent electrical shock and equipment dam­ zontally with the bifurcated contacts pointing down. age. More than one disconnect may be involved. 5. AU wiring must comply with applicable local electri­ 4. For surface mounting, use the back of the subbase as cal codes, ordinances, and regulations. a template to mark the four screw locations. Drill the pilot 6. After installation is complete, check out product holes. operation as provided in these instructions. 5. Insert the mounting screws using four M3.5 x 0.6 screws tightened securely. A. G. • 9-93 • ©Honeywell Inc. /993 • Form Number 65-0/64 Fig. l-Top and front view of Q7800A1021 wiring subbase (2-sided) with dimensions in millimeters. ,- USE M3.5 x 0.6 MOUNTING SCREWS (4) G WN) 3 4 5 6 7 8 9 10 F -36 - n 1 REMOVE ONLY FOR TERMINAL TEST ACCESS. h43942 W iring 5. Recommendedgroundingpractices: a. Each EC7800 SERIESRelay Module will have an earthgroundterminalG that mustbe grounded 1. Refer to the equipmentmanufacturer’swiring infor- to the metal control panel with wire as short as mation and the appropriateEC7800SERIESRelay Mod- practical. Each ground wire must be capableof ule Specificationsfor correct subbasewiring. carrying a fault currentequalto the rating of the 2. Provide overloadprotection and disconnectmeans protectivefuse (20 amperes). as required.Disconnectthe power supply from the main b. The earthgroundprovidesa connectionbetween disconnectbeforebeginninginstallationto preventelectri- the subbaseand the control panel or the equip- cal shock and equipmentdamage.More than one discon- nectmay be involved. ment. The earthgroundwire must be capableof 3. All wiring must comply with appropriateelectrical conductingthe current to blow the 20A fuse (or codes,ordinancesandregulations. breaker)in eventof an internal shortcircuit. The 4. For high temperatureinstallations,usewire selected EC7800SERIESRelay Module needsa low im- for a temperaturerating abovethe notedmaximumoperat- pedancegroundconnectionto theequipmentframe ing temperature.The flame detectorleadwiresshould be which, in turn, needsa low impedanceconnection moistureresistant. to earth ground. For a ground path to be low a. For the ignition leadwire,useHoneywell specifl- impedanceat RF frequencies,theconnectionmust cation no. R1061012Ignition Cable or equiva- be made with minimum length conductorsthat lent. (This wire is ratedat 177”C for continuous havemaximumsurfaceareas.Wide strapsorbrack- duty, and up to 260”C for intermittentuse.It has ets arepreferredratherthan leadwires.Be careful beentestedto 25,000volts.) to ensurethat mechanicallytightenedjoints along b. For the flamedetectorF leadwire,useHoneywell the groundpath,suchaspipe or conduitthreadsor specificationno. R1298020or equivalent.(This surfacesheld togetherwith fasteners,are free of wire is ratedat 204”C for continuousduty. It is nonconductivecoatingsand havecorrosion-pro- tested for operationup to 600 volts and break- tectedmating surfaces. down up to 7500 volts.) 6. Recommendedwire routing for flame detector c. For ignition installationin a contaminatingenvi- leadwires: ronment, use Honeywell specification no. a. Do not run high voltageignition transformerwires R1239001High TensionIgnition Cableor equiva- in the same conduit with the flame detection lent. (This wire is resistanto severeconditionsof wiring. oil, heat and corona, and is testedto withstand b. Do not route scannerwires in the sameconduit high voltagesup to 25,000Vrms in a salt bath for with line voltagecircuits. oneminutewithoutbreakdown.It is ratedat 93”C) c. Scannerwiring not utilizing armor cable should for continuousduty, andup to 177”C for intermit- be enclosedin metal cableor conduit. tent use. d. Follow directionsin the Flame DetectorInstruc- tions. 2 7. Maximum wire lengths for flame detectorleadwires are limited by the flame signal strength. Checkout 8. Make sure that loads do not exceed the terminal ratings; refer to the labels on the EC7800 SERIES Relay After installation, perform a completecheckout of the Module, or ratings in the EC7800 SERlES Relay Module system. Follow information supplied by the equipment Specifications, manufacturerand instructionsfurnished with the EC7800 9. Check the power supply circuit. The voltage and SERIES Relay Module. frequencytolerancemust match thoseof the EC7800 SE- RlES Relay Module. Do not connectthe EC7800 SERIES SERVICE NOTE: Voltagecheckscan be accomplishedby Relay Module to a power supply circuit that is subject to removing the Electrical AccessSlot Covers and using line voltage variations, such as would occur with on-off the electrical accessslots on the sidesof the Q78OOA. switching of heavy loads. A separatepower supply circuit may be required for the EC7800 SERIES Relay Module. Add the required disconnect meansand overload protec- tion. 10. Check all wiring circuits according to the EC7800 I A! CAUTION - 1 ReplaceElectrical AccessSlot Covers after per- SERIESRelay Module Specificationsbeforeinstalling the forming voltage checks or anytime they are re- EC7800 SERIES Relay Module on the subbase. moved. 11. Install the EC7800 SERIES Relay Module. 12. Restorepower to the panel. IMPORTANT: Do not run high voltage ignition trans- former wires in the sameconduit with themme detector wiring. IMPORTANT: Make sure no subbasewiring is project- ing beyond the terminal blocks. Tuck wiring in against the back of the subbaseso it doesnot interfere with the knife blade terminals or bifurcated contacts. 65-0164
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

Honeywell Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

Honeywell Q7800A 1005 adalah universal wiring subbase 22-terminal yang dirancang khusus untuk EC7800 SERIES Relay Modules. Subbase ini menyediakan terminal untuk field wiring dengan knife blade terminals yang terhubung ke kontak bifurkasi Q7800A, memastikan koneksi listrik yang andal. Dengan enclosure NEMA 1 dan sekrup pemasangan M3.5 x 0.6, produk ini cocok untuk aplikasi panel mounting di berbagai peralatan pembakaran industri. Cari subbase universal wiring untuk sistem kontrol pembakar? Q7800A adalah pilihan tepat.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Apa fungsi Honeywell Q7800A 1005?

Honeywell Q7800A 1005 berfungsi sebagai universal wiring subbase 22-terminal untuk EC7800 SERIES Relay Modules. Subbase ini menyediakan terminal untuk field wiring dan menghubungkan knife blade terminals pada relay module ke kontak bifurkasi, memungkinkan koneksi listrik yang aman dan andal dalam sistem kontrol pembakar industri.

Apa spesifikasi teknis Honeywell Q7800A 1005?

Spesifikasi Honeywell Q7800A 1005 meliputi enclosure NEMA 1, 22 terminal, sekrup pemasangan M3.5 x 0.6, dan berat 196 gram. Produk ini memiliki knockouts di bagian belakang, atas, dan bawah untuk sambungan conduit, serta dirancang untuk panel mounting dengan posisi vertikal standar yang direkomendasikan.

Di mana beli Honeywell Q7800A 1005 di Indonesia?

Anda dapat membeli Honeywell Q7800A 1005 melalui 3G Electric, distributor resmi yang memasok dan mengirimkan produk ini ke seluruh Indonesia. Kami menangani logistik dan bea cukai, sehingga Anda dapat menerima universal wiring subbase ini dengan mudah untuk kebutuhan peralatan pembakaran industri Anda.

Bagaimana cara memasang Honeywell Q7800A 1005?

Pasang Honeywell Q7800A 1005 di lokasi dengan suhu sekitar yang sesuai dengan rating EC7800 SERIES Relay Module. Mount subbase di posisi vertikal dengan kontak bifurkasi menghadap ke atas, hindari posisi horizontal. Gunakan sekrup M3.5 x 0.6 untuk pemasangan langsung di panel kontrol, dan pastikan daya dimatikan sebelum instalasi.

Digunakan dalam

Aplikasi umum untuk Honeywell
Commercial kitchen and inflight-catering steam boilers — RM7890 / RM7895 flame relays with UV detection
Food-processing ramp-and-dwell ovens — DBC2000E / DBC2100E controllers
Hotel and hospital boiler plants — VR8205 combination gas controls
Petrochemical tank-farm heating — V4xxx gas-valve bodies with ML7420 actuators
Retrofit swap-outs from legacy Fireye / Satronic — Honeywell replacement kits

Honeywell Produk

3G Electric memasok Honeywell controls. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Pembakar & Pembakaran Pompa & Kompresor Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
Base Q7800 B 1003
Honeywell
Base Q7800 B 1003
Quartz 114372
Honeywell
Quartz 114372
Box S4570 LS 1091 U
Honeywell
Box S4570 LS 1091 U
Housing S4560 C 1053 U
Honeywell
Housing S4560 C 1053 U
Relay EC 7823 A 1004
Honeywell
Relay EC 7823 A 1004
Honeywell
Honeywell
Housing S4565 CF 1052 U

Lainnya dari Honeywell

Lihat semua Honeywell suku cadang
Box S4565 C 1025 V01U
Honeywell
Box S4565 C 1025 V01U
Housing S4565 A 2050 U
Honeywell
Housing S4565 A 2050 U
Housing S4565 BF 1062 U
Honeywell
Housing S4565 BF 1062 U
Honeywell
Honeywell
ST7800 A 1013 prepurge
Honeywell
Honeywell
Pressure switch DWR1 0.2/1.6 bar
Honeywell
Honeywell
Prepurge ST7800 A 1005
Honeywell
Honeywell
KT COMB 50 (pair of flanges)
Honeywell
Honeywell
Pressure switch DWR6 0.5/6 bar