Fireye BurnerLogix Z Flame Safeguard - Flame Safeguard Controls
FireyeFlame Safeguard Controls

Fireye BurnerLogix Z Flame Safeguard

Fireye BurnerLogix Z Flame Safeguard adalah pengaman nyala api berbasis mikroprosesor yang dirancang untuk manajemen pembakar industri dengan kontrol ketel uap terintegrasi. Model ZB110 ini memiliki persetujuan CE…

SKU 3G-OTH-02781

Also listed as: BURNERLOGIXZ · BURNERLOGIX Z

Brand
Fireye
Item
BurnerLogix Z Flame Safeguard
Category
Flame Safeguard Controls
Available to Order
Ready stock & customs handled
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Ships to: Jakarta, Surabaya, Bandung, Medan, Batam
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Indonesia

Phone
+65 8878 8355

Technical Specifications

Fireye
Models
ZB110
Category
Flame Safeguard Controls
Approvals
CE, cULus, FM Approved

Datasheet Content

[{"filename":"ZB110-SPEC-BurnerLogiX_Z_Specifications_English_2007-08-01.pdf","text":"FLAME SAFEGUARD ZB110-SPEC\n August 1, 2007\n\nPRODUCT GUIDE\nSPECIFICATION\n\n\n\n FIREYE BurnerLogix\n FLAME SAFEGUARD\n BURNER MANAGEMENT\n with INTEGRATED\n BOILER CONTROL\n1. GENERAL 1.3 FLAME SAFEGUARD CONTROL\n1.1 OVERVIEW The burner management control system shall include\n Each burner shall be equipped with a micro- flame safeguard functions to provide: (1) automatic\n processor based burner management flame safeguard sequencing of the boiler system through pre-purge,\n control with integrated boiler control functions. pilot trial for ignition (PTFI), main trial for ignition\n (MTFI), run (AUTO), and post purge. (2) flame\n1.1.1 The control system shall be provided by Fireye, Inc. or proving and lockout on flame failure during PTFI,\n written approved equal. MTFI, and run.\n\n1.2 BOILER CONTROL 1.4 CODES AND STANDARDS\n The control shall utilize signal inputs from solid state The control shall be listed by Underwriters\n sensors as inputs for boiler steam pressure or boiler Laboratories in accordance with US and Canadian\n water temperature for on/off control, modulation with standards and Factory Mutual for its intended\n PID control, and high and low alarm limits of the purposes.\n appropriate pressure and temperature sensors.\n2. SYSTEM HARDWARE\n2.1 FLAME SAFEGUARD WITH INTEGRATED where the characteristics of the pilot and main flames\n BOILER CONTROL are separately learned in order to set the on/off\n Major functions of the boiler management system shall thresholds and optimizing safety.\n have the following capabilities to provide:\n 2.1.4 Flame proving and lockout on flame failure during\n2.1.1 User selectable burner operating parameters such as PTFI, MTFI and run.\n purge time, PTFI & MTFI time, post purge time, and\n specific operation of the various interlocks. 2.1.5 The control shall provide a check-run switch to allow a\n qualified service technician to halt the burner sequence\n2.1.1.1 All burner operating parameters become permanent in any of five different positions:\n after 8 hours of burner on time. ƒ High fire purge\n ƒ Low fire purge\n2.1.2 User configurable boiler parameters such as setpoint, ƒ Pilot trial for ignition\n thermal shock, standby water, LAG1 and LAG2. ƒ Main trial for ignition\n ƒ Low fire (burner on)\n2.1.2.1 Boiler operating parameters are password protected.\n 2.1.6 Full modulating control of fuel and combustion air that\n2.1.3 An adaptive Infrared flame scanning detection system are mechanically linked.\n\n\n 1\n\f ƒ Power Consumption: 20 VA maximum\n2.1.7 Modulation of the firing rate motor to meet system ƒ 2000 VA maximum connected load\n demand using Proportional, Integral and Derivative ƒ 0.5G continuous vibration\n control.\n 2.1.19 The control shall have the following storage\n2.1.8 Two (2) inputs to provide the following user selectable temperature limits:\n functions: ƒ Temperature: -40qF to 158qF (-40qC to 70qC)\n ƒ Select Lead/Lag1 operation. ƒ Humidity: 0% to 85% Non-condensing\n ƒ Select Lead/Lag2 operation.\n ƒ Revert to pilot operation. 2.2 WIRING BASE\n ƒ Halt the sequence in pilot only mode.\n A pre-wired or terminal block wiring base shall be\n ƒ Low fire only operation.\n provided which will allow for all system terminations\n ƒ Forced on operation.\n to be completely wired prior to the installation of the\n These inputs shall be line voltage powered.\n control. The control shall be removable or replaceable\n without removing any wiring terminations.\n2.1.9 Line voltage terminal inputs for lockout, pre-ignition,\n recycle limits and interlocks.\n 2.3 KEYPAD/DISPLAY MODULE\n2.1.10 Three (3) analog inputs user configurable to monitor: A plug-in module shall be provided to program and/or\n ƒ Steam Pressure review all system setpoints as well as all system\n ƒ Boiler water Temperature operating parameters (eg: values of the analog and\n ƒ Stack Temperature digital inputs and outputs).\n ƒ Outdoor Temperature\n 2.3.1 The module shall consist of a two (2) line with sixteen\n The input control signal shall be 4-20 mA.\n (16) characters per line liquid crystal (LCD) or vacuum\n fluorescent (VFD) display and multi-functional 4-key,\n2.1.11 One (1) proportional analog output for modulation\n positive action keypad.\n control of firing rate damper motor.\n The proportional output shall be 4-20 ma. 2.3.2 Descriptive mnemonic codes shall be provided for all\n system setpoints and operating parameters.\n2.1.12 Alpha-numeric multi-line LCD or VFD display to\n 2.3.3 The LCD keypad/display module shall operate within\n continually indicate operating parameters as well as\n the following temperature limits: -4qF to 140qF (-20qC\n first out annunciation.\n to 60qC).\n2.1.13 Status light emitting diodes (LED’s) to provide 2.3.4 The VFD keypad/display module shall operate within\n operating status as well as lockout code the following temperature limits: -40qF to 140qF (-40C\n identification. to 60qC).\n 2.3.5 The keypad/display module shall have the capability to\n2.1.14 Thermal stress delayed release to modulation.\n be remotely mounted to a distance of 8 feet (2.43\n meters).\n2.1.15 Damper motor high and low fire damper motor\n position proving. 2.3.6 When remotely mounted, both the LCD and VFD\n display modules shall provide NEMA 4 protection.\n2.1.16 Non-volatile lockout and history files with the last 10\n lockouts readable through the optional display. 2.4 PRESSURE SENSORS\n All pressure sensors shall be factory calibrated to\n2.1.17 Field replaceable 10 amp fuse in the valve and provide accurate pressure control over the entire\n ignition circuit for short circuit protection. pressure range of the sensor. No field calibration or\n adjustment is required.\n2.1.18 The control system shall operate within the following\n limits:\n 2.4.1 All pressure sensors shall provide a 4-20 mA output\n ƒ Temperature: -40qF to 140qF (-40qC to 60qC)\n signal over the full range.\n ƒ Humidity: 0% to 85% Non-condensing\n ƒ Voltage: 120 VAC (+10%, -15%) 50/60 Hz\n 2.4.2 The following pressure ranges shall be available:\n\n\n\n 2\n\f ƒ 0 to 15 PSI exit point is user defined.\n ƒ 0 to 30 PSI\n ƒ 0 to 200 PSI 3.2.1.3 Segment method shall go from low fire to high fire in\n ƒ 0 to 300 PSI 16 separate segments, increasing to the next segment\n based on increasing steam pressure (or water\n2.5 TEMPERATURE SENSORS temperature) values, or a user defined timed override\n All temperature sensors shall be factory calibrated to (1-60 minutes).\n provide accurate temperature control over the entire\n temperature range of the sensor. No field calibration or 3.2.1.4 Segment method shall provide user defined start point\n adjustment is required. and exit point.\n\n2.5.1 All temperature sensors shall provide a 4-20 mA 3.2.2 The user shall be able to define the maximum firing\n output signal over the…

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Fireye Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

Fireye BurnerLogix Z Flame Safeguard adalah pengaman nyala api berbasis mikroprosesor yang dirancang untuk manajemen pembakar industri dengan kontrol ketel uap terintegrasi. Model ZB110 ini memiliki persetujuan CE, cULus, dan FM Approved, serta menyediakan fungsi sekuensing otomatis seperti pre-purge, PTFI, MTFI, dan post purge. Produk ini cocok untuk aplikasi pembakar industri yang membutuhkan pengaman nyala api dan pembuktian nyala yang andal.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Frequently Asked Questions

Apa fungsi utama Fireye BurnerLogix Z Flame Safeguard?

Fireye BurnerLogix Z Flame Safeguard berfungsi sebagai pengaman nyala api yang mengelola sekuensing pembakar industri secara otomatis, termasuk pre-purge, PTFI, MTFI, dan post purge. Kontrol ini juga terintegrasi dengan kontrol ketel uap untuk modulasi dan alarm tekanan/suhu.

Apa spesifikasi model Fireye ZB110?

Model Fireye ZB110 termasuk dalam kategori Flame Safeguard Controls dengan persetujuan CE, cULus, dan FM Approved. Kontrol ini menggunakan input sensor solid state untuk tekanan uap atau suhu air ketel uap, serta memiliki parameter operasi yang dapat dipilih pengguna seperti waktu purge dan PTFI.

Di mana beli Fireye BurnerLogix Z Flame Safeguard di Indonesia?

Anda dapat membeli Fireye BurnerLogix Z Flame Safeguard melalui 3G Electric, distributor resmi yang memasok dan mengirimkan peralatan industri ini ke seluruh Indonesia. Kami menangani logistik dan bea cukai untuk memastikan produk sampai ke lokasi Anda.

Bagaimana cara memilih pengaman nyala api untuk pembakar industri?

Pilih pengaman nyala api seperti Fireye BurnerLogix Z yang memiliki persetujuan CE, cULus, dan FM Approved. Pastikan kontrol mendukung sekuensing otomatis (pre-purge, PTFI, MTFI, post purge) dan terintegrasi dengan kontrol ketel uap untuk aplikasi Anda.

Apakah Fireye ZB110 kompatibel dengan sistem pembakar lama?

Fireye ZB110 dirancang sebagai pengganti kontrol pembakar berbasis mikroprosesor dengan parameter operasi yang dapat dipilih pengguna. Untuk kompatibilitas spesifik, konsultasikan dengan teknisi berkualifikasi karena kontrol ini memerlukan sensor solid state untuk input tekanan/suhu.

Used in

Common applications for Fireye
Power-plant auxiliary boiler — M-Series II controller with UV flame scanner, programmed for gas/oil switchover and flame-presence monitoring.
Refinery process heater — MP100E programmer module managing multi-stage ignition and flame-out shutdown interlocks on high-pressure burners.
Petrochemical facility thermal oxidizer — MAUV1T UV amplifier module processing scanner signal from high-temperature burner housings with immune-response filtering.
Large-scale industrial oven (metal treating) — M-Series II with remote reset capability and dual-fuel solenoid isolation for operator safety and burner protection.
Cogeneration plant fuel-gas burner — Fireye scanner and modular controller stack integrated into BMS with remote monitoring of flame status and controller fault codes.

Fireye Products

3G Electric supplies Fireye flame safeguard controls. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
D-Series 70D40 and 70D41 Burner Control. Plug-in Amplifier Modules permit the selection of ultraviolet, repetitive self-check ultra-violet, AUTOCHECK infrared, or rectification methods of flame detection. The control system includes a safe start check, effective on each start. If the flame signal (real or simulated) is detected, the unit cannot be started
Fireye
D-Series 70D40 and 70D41 Burner Control. Plug-in Amplifier Modules permit the selection of ultraviolet, repetitive self-check ultra-violet, AUTOCHECK infrared, or rectification methods of flame detection. The control system includes a safe start check, effective on each start. If the flame signal (real or simulated) is detected, the unit cannot be started
BurnerLogiX Honeywell Adapter. With the 60-BLX-HON-VP & 60-BLX-HON-NVP Honeywell to Fireye wiring base adapters, you can easily convert from Honeywell RM7800/7840 to Fireye BurnerLogiX. Whether you’re looking to reduce costs, or prefer high-quality, Made in USA controls, our adapters are the ideal solution for seamless integration
Fireye
BurnerLogiX Honeywell Adapter. With the 60-BLX-HON-VP & 60-BLX-HON-NVP Honeywell to Fireye wiring base adapters, you can easily convert from Honeywell RM7800/7840 to Fireye BurnerLogiX. Whether you’re looking to reduce costs, or prefer high-quality, Made in USA controls, our adapters are the ideal solution for seamless integration
PF Series MBPF-100S Burner Control. The MBPF-100S, MB-600PF, MBPF-200S and MBPF-202S modules provide visual indication and electrical output that signal the user regarding flame presence in a combustion chamber. The module uses Fireye optical ultra-violet scanners and/or flame rods to sense flame presence independently or as components in a burner management system
Fireye
PF Series MBPF-100S Burner Control. The MBPF-100S, MB-600PF, MBPF-200S and MBPF-202S modules provide visual indication and electrical output that signal the user regarding flame presence in a combustion chamber. The module uses Fireye optical ultra-violet scanners and/or flame rods to sense flame presence independently or as components in a burner management system
BF Series Bi-Flame Dual Burner Monitoring System. Obsolete, can be replaced with MB Series MB600S Burner Control
Fireye
BF Series Bi-Flame Dual Burner Monitoring System. Obsolete, can be replaced with MB Series MB600S Burner Control
Flame-Monitor E120 Flame Safeguard. The Fireye® E120 Flame-Monitor™ System is specifically designed for applications requiring 220VAC power. It provides the same advanced burner management features as the E110 Flame-Monitor, with added compatibility for 220VAC power sources
Fireye
Flame-Monitor E120 Flame Safeguard. The Fireye® E120 Flame-Monitor™ System is specifically designed for applications requiring 220VAC power. It provides the same advanced burner management features as the E110 Flame-Monitor, with added compatibility for 220VAC power sources
MB Series MB600S Burner Control. MB SERIES control has been engineered to meet the operational, safety and reliability requirements demanded by the industrial process heat market. It is a fully integrated control, complete with all functions built into one module, offering the opportunity to greatly reduce cost and space requirements normally required by other non-integrated systems
Fireye
MB Series MB600S Burner Control. MB SERIES control has been engineered to meet the operational, safety and reliability requirements demanded by the industrial process heat market. It is a fully integrated control, complete with all functions built into one module, offering the opportunity to greatly reduce cost and space requirements normally required by other non-integrated systems

More from Fireye

View all Fireye parts
BurnerLogiX Y Flame Safeguard. The BurnerLogix flame safeguard controler boast a sophisticated array of features designed to enhance efficiency, safety, and ease of use in combustion systems. Employing built-in techniques and algorithms, the BurnerLogix is equipped to learn and adapt to the unique characteristics of the fuel being burned. This intelligent system dynamically sets internal thresholds, optimizing detection accuracy under a diverse range of operating conditions. When firing conditions deviate unfavorably, the adaptive IR system swiftly and safely initiates a shutdown of the burner, mitigating potential risks
Fireye
BurnerLogiX Y Flame Safeguard. The BurnerLogix flame safeguard controler boast a sophisticated array of features designed to enhance efficiency, safety, and ease of use in combustion systems. Employing built-in techniques and algorithms, the BurnerLogix is equipped to learn and adapt to the unique characteristics of the fuel being burned. This intelligent system dynamically sets internal thresholds, optimizing detection accuracy under a diverse range of operating conditions. When firing conditions deviate unfavorably, the adaptive IR system swiftly and safely initiates a shutdown of the burner, mitigating potential risks
Fireye
Fireye
BurnerLogix YZ300 Annunciator. The YZ300 Module shall interface with the Fireye YB110 or ZB110 BurnerLogix and expand on the YB110 or ZB110 annunciation capabilities
M4RT1 Flame Safeguard Control. Designed to provide automatic ignition and continuous flame monitoring, the M4RT1/M4RT24 is meant for commercial-sized heating and process burners that use gaseous fuels
Fireye
M4RT1 Flame Safeguard Control. Designed to provide automatic ignition and continuous flame monitoring, the M4RT1/M4RT24 is meant for commercial-sized heating and process burners that use gaseous fuels
MicroM Series MEC120 Flame Safeguard. The MicroM is designed to be backward compatible with existing TFM, UVM and M-Series II controls. The MicroM MEC120 and MEC230 chassis with the appropriate MEP100, MEP200 and MEP500 series programmers provide operations similar to its predecessors and are usually directly interchangeable
Fireye
MicroM Series MEC120 Flame Safeguard. The MicroM is designed to be backward compatible with existing TFM, UVM and M-Series II controls. The MicroM MEC120 and MEC230 chassis with the appropriate MEP100, MEP200 and MEP500 series programmers provide operations similar to its predecessors and are usually directly interchangeable
SB Series Flame Safeguard. The Fireye SB Series flame safeguard control is a compact, microprocessor based, modular burner management system designed to provide automatic ignition and continuous flame monitoring for commercial sizes of heating and process equipment firing any type of fuel
Fireye
SB Series Flame Safeguard. The Fireye SB Series flame safeguard control is a compact, microprocessor based, modular burner management system designed to provide automatic ignition and continuous flame monitoring for commercial sizes of heating and process equipment firing any type of fuel
M-Series II Flame Safeguard MC120. Modular M-Series II Flame Safeguard Controls are compact, modular burner management systems. They are designed to provide automatic ignition and continuous flame monitoring for commercial sizes of heating and process burners that use gas and/or light oil fuels
Fireye
M-Series II Flame Safeguard MC120. Modular M-Series II Flame Safeguard Controls are compact, modular burner management systems. They are designed to provide automatic ignition and continuous flame monitoring for commercial sizes of heating and process burners that use gas and/or light oil fuels
BurnerPRO Flame Safeguard. BurnerPRO controls are the ideal solution for both new installations and retrofit of Siemens LFL controls. Many BurnerPRO models are functionally compatible with select Siemens LFL control models and can use the existing wiring base with no external wiring changes. The controls are also compatible with Satronic TMG controls with minor wiring changes. Please refer to the product overview document for compatibility listings
Fireye
BurnerPRO Flame Safeguard. BurnerPRO controls are the ideal solution for both new installations and retrofit of Siemens LFL controls. Many BurnerPRO models are functionally compatible with select Siemens LFL control models and can use the existing wiring base with no external wiring changes. The controls are also compatible with Satronic TMG controls with minor wiring changes. Please refer to the product overview document for compatibility listings
Flame-Monitor E110 Flame Safeguard. In conjunction with limit and operating controls, the Flame-Monitor E110 programs the burner/blower motor, ignition and fuel valves to provide for proper and safe burner operation. The control also provides current operating status and lockout information in the event of a safety shutdown
Fireye
Flame-Monitor E110 Flame Safeguard. In conjunction with limit and operating controls, the Flame-Monitor E110 programs the burner/blower motor, ignition and fuel valves to provide for proper and safe burner operation. The control also provides current operating status and lockout information in the event of a safety shutdown