FBR FNDP 160/2 TL 2P SI - Burners & Combustion
FBRBurners & Combustion

FBR FNDP 160/2 TL 2P SI

FBR FNDP 160/2 TL 2P SI adalah pembakar heavy oil dua tahap (2 stages) yang dirancang untuk aplikasi industri berat. Dengan daya termal maksimum 1900 kW dan aliran bahan bakar 165 kg/jam, unit ini dilengkapi motor…

SKU 3G-FBR-00302

Merek
FBR
Item
FNDP 160/2 TL 2P SI
Kategori
Burners & Combustion
UNSPSC
40101834 — Burners
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Distributor Resmi
Langsung dari OEM
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

FBR
Weight
35 kg
stage
2 stages
fuel type
Heavy oil
nozzle mm
210
fan motor w
4
power kw max
1900
power kw min
474
flow kg h max
165
flow kg h min
42
ip protection
IP 40
noisiness dba
84.4-85.4
pump motor kw
0.55
electrical supply
3
power supply info
- 50Hz
current absorption a
7.45
thermal power mcal h
407/776-1600
nominal electric power w
17
max combustion air temp c
60

Konten Lembar Data

HEAVY-OIL BURNERS TWO STAGES SK072029_A_en FNDP 130/2 EVO - FNDP 160/2 Burners for heavy-oil two stages with: die-cast aluminum body, fan at high pressurisation, combustion head with adjustment at high efficiency and high flame stability and hydraulic system of regulation combustive air on the two stages of flame. Disposition rationalized of the components with accessibility facilitated for operations of setting and maintenance. Complete of flange and gasket for installation on generator, nozzles, flexible pipes, line filter electrically heated and equipped with thermostat. Available in versions with 2-pole or 4-pole pump motor. Fig. FNDP 160/2 FNDP 130/2 EVO - FNDP 160/2 HEAVY-OIL BURNERS TWO STAGES SK072029_A_en TECHNICAL DATA FNDP 130/2 EVO - FNDP 160/2 MODEL FNDP 130/2 EVO FNDP 160/2 Flow min. 1°st. / min. 2°st. - max. 2°st. * [kg/h] 34/64-137 42/80-165 Thermal power min. 1°st. / min. 2°st. - max. 2°st. * [Mcal/h] 330/621-1329 407/776-1600 Thermal power min. 1°st. / min. 2°st. - max. 2°st. * [kW] 380/730-1542 474/900-1900 Fuel: HEAVY-OIL MAX 20°E at 50°C Intermitted working operation (min. 1 stop every 24 hours) two stages Environmental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max. temperature combustion air [°C] 60 Nominal electric power [kW] 14 17 Fan motor [kW] 2.2 4 Pump motor (2-pole version) [kW] 0.55 0.55 Pump motor (4-pole version) [kW] 0.75 0.75 Nominal current absorption [A] 4.35 7.45 Nominal fan motor current absorption [A] 4.35 7.45 Nominal pump motor current absorption [A] 1.32 1.32 Nominal auxiliary absorption [A] 0.8 0.8 Resistances [kW] 11 12 Power supply: 3~400V, 1N~230V - 50Hz Electric protection degree: IP฀40 Noisiness ** min-max [dBA] 82-83 84.4-85.4 * Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** Measured sonourous pressure in the combustion lab, with funcional burner on beta boiler in a distance of 1 m (UNI EN ISO 3746). FNDP 130/2 EVO - FNDP 160/2 HEAVY-OIL BURNERS TWO STAGES SK072029_A_en OPERATING RANGE DIAGRAM [mbar] 16 FNDP 130/2 EVO 14 12 10 8 6 4 2 0 200 400 600 800 1000 1200 1400 1600 [kW] Fig. X = Thermal power Y = Pression in the combustion chamber The firing rates has been obtained based on test boilers in accordance with EN267 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non- compliance, contact the manufacturer. [mbar] 16 FNDP 160/2 14 12 10 8 6 4 2 0 200 400 600 800 1000 1200 1400 1600 1800 2000 [kW] Fig. X = Thermal power Y = Pression in the combustion chamber The firing rates has been obtained based on test boilers in accordance with EN267 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non- compliance, contact the manufacturer. FNDP 130/2 EVO - FNDP 160/2 HEAVY-OIL BURNERS TWO STAGES SK072029_A_en DIMENSIONS [MM] 40 183 F 320 D 320 N E A B TC - TL C1 - C2 * Fig. Dimensions MODEL A B C1 C2 * D E F N FNDP 130/2 EVO 460 407 960 1545 209 510 211 20 FNDP 160/2 460 407 960 1545 209 510 211 20 * Overall dimension with the burner out in position of maintenance. BOILER PLATE ** Suggested dimension of connection between burner and generator. Fig. Boiler plate MODEL L min L max M N min N** N max FNDP 130/2 EVO mm 340 368 M14 220 220 250 FNDP 160/2 mm 340 368 M14 220 220 250 FLAME TUBE LENGTH Flame tube length must be selected based on the specifications supplied by boiler manufacturer and, in any case, it must be greater than the thickness of the boiler door included its insulation. In case of boilers with flame inversion or front flue combustion chambers, it is necessary to insulate the area between the flame tube and front door with refractory material. This protection material must not impede flame tube extraction. MODEL TC TL *** FNDP 130/2 EVO mm 210 400 FNDP 160/2 mm 210 400 *** For different flame lengths, please contact our Technical-Sales Department. FNDP 130/2 EVO - FNDP 160/2 HEAVY-OIL BURNERS TWO STAGES SK072029_A_en PRODUCT SPECIFICATION PRODUCT SPECIFICATION Heavy-oil burners two stages. DETAILED SPECIFICATION Heavy-oil burners two stages,฀composed by: • Die-cast aluminum body; • Fan at high pressurisation, at reverse blades for FNDP 130/2 EVO; • Combustion head with adjustment at high performance and elevated flame stability; • Flange and insulating gasket for fixing at boiler; • Three-phase power supply; • Photodiode for flame detection; • IP 40 electric protection level; • Supports and tierods for burner extraction; • Easy extraction of combustion head without get off the burners by bolier; • Pump controlled by dedicated electric motor; available in 2-pole or 4-pole version; • Safety air pressure switch to stop the burner in lock-out (by stopping the pump motor) in case of failed or anomalous fan operation; • Thermostats for regulating: temperature of 1st resistance group, temperature of 2nd resistance group, minimum temperature. CONFORMING TO: • CE rules; • 2014/30/UE Directive E.M.C.; • 2014/35/UE Directive L.V.; • 2006/42/CE - 2006/42/EG - 2006/42/EC Directive MAC; • 2014/68/EU (art.4, par.3) Directive P.E.D.; • Reference rules: EN267 (liquid fuel) - EN746-2 (industrial thermoprocessing equipment) STANDARD EQUIPMENT • Flexible hoses for connection; • Line filter electrically heated and equipped with a thermostat; • Isomart gasket; • Nozzles; • Flange with insulating gasket; • Burner nameplate; • Warranty; • Instruction handbook for installation, use and maintenance. OPTIONAL • Noise protection. The illustrations and data here shown are indicative. F.B.R. Bruciatori S.r.l. reserves the right to bring, without any obligation of warning, any changes that would be appropriate to the continuing development of their products FNDP 130/2 EVO - FNDP 160/2
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

FBR Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

FBR FNDP 160/2 TL 2P SI adalah pembakar heavy oil dua tahap (2 stages) yang dirancang untuk aplikasi industri berat. Dengan daya termal maksimum 1900 kW dan aliran bahan bakar 165 kg/jam, unit ini dilengkapi motor kipas 4 kW, motor pompa 0,55 kW, dan proteksi IP 40. Pembakar ini cocok untuk ketel uap dan peralatan pembakaran lain yang memerlukan pembakar heavy oil andal.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Apa spesifikasi teknis FBR FNDP 160/2 TL 2P SI?

FBR FNDP 160/2 TL 2P SI memiliki daya termal 474–1900 kW, aliran bahan bakar 42–165 kg/jam, motor kipas 4 kW, motor pompa 0,55 kW, arus nominal 7,45 A, proteksi IP 40, dan tingkat kebisingan 84,4–85,4 dBA. Suplai listrik 3~400V, 50 Hz.

Untuk apa FBR FNDP 160/2 TL 2P SI digunakan?

Pembakar ini digunakan untuk pembakaran heavy oil dua tahap pada ketel uap industri, pemanas termal, dan peralatan pembakaran lain yang memerlukan pembakar heavy oil dengan kapasitas besar. Cocok untuk aplikasi di pabrik kelapa sawit, semen, dan industri pengolahan lainnya.

Bagaimana cara memilih pembakar heavy oil yang tepat?

Pilih pembakar berdasarkan daya termal yang dibutuhkan (kW), jenis bahan bakar (heavy oil), jumlah tahap (2 stages), dan spesifikasi listrik (3~400V, 50 Hz). FBR FNDP 160/2 TL 2P SI menawarkan daya 474–1900 kW dan aliran 42–165 kg/jam, cocok untuk aplikasi industri menengah hingga besar.

Di mana beli FBR FNDP 160/2 TL 2P SI di Indonesia?

Anda dapat membeli FBR FNDP 160/2 TL 2P SI melalui 3G Electric, distributor resmi yang memasok dan mengirimkan peralatan industri ke seluruh Indonesia. Kami menangani logistik dan bea cukai untuk memastikan produk sampai ke lokasi Anda.

Apa keunggulan FBR FNDP 160/2 TL 2P SI dibandingkan model lain?

FBR FNDP 160/2 TL 2P SI memiliki bodi aluminium die-cast, kepala pembakaran dengan penyesuaian efisiensi tinggi, dan sistem hidrolik pengaturan udara pembakaran pada dua tahap. Dengan daya termal hingga 1900 kW dan aliran 165 kg/jam, pembakar ini menawarkan stabilitas nyala api yang tinggi.

Digunakan dalam

Aplikasi umum untuk FBR
Hospitality and commercial HVAC — cast-iron boiler plants in hotels and shopping complexes
Pharmaceutical and biotech process heat — gas-fired burners with ATEX gas trains for classified-zone requirements
Medical-waste and bio-hazard incineration — FGP progressive dual-fuel systems
Food and beverage steam boilers — single-stage G-series for continuous-duty cycles
Marine and offshore platforms — IP54-rated X-series for high-humidity marine operations

FBR Produk

3G Electric memasok FBR burners & combustion. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Rangkaian Gas & Katup Gas Transformator Pengapian Kontrol Pembakar Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
FNDP 160/2 TC 2P SI
FBR
FNDP 160/2 TC 2P SI
FNDP 160/2 TL 4P SI
FBR
FNDP 160/2 TL 4P SI
FNDP 160/2 TC 4P SI
FBR
FNDP 160/2 TC 4P SI
FNDP 100/2 TL SI
FBR
FNDP 100/2 TL SI
FNDP 160/M TL 4P SA
FBR
FNDP 160/M TL 4P SA
FNDP 70/2 TL SI
FBR
FNDP 70/2 TL SI

Lainnya dari FBR

Lihat semua FBR suku cadang
FNDP 100/2 TC
FBR
FNDP 100/2 TC
FBR
FBR
FNDP 750/M TL MEC
FBR
FBR
FNDP 250/M TL MEC
FBR
FBR
FNDP 450/M TL MEC
FBR
FBR
FNDP 350/M TL MEC
FBR
FBR
FNDP 150/M TL
FNDP 125/2 TC
FBR
FNDP 125/2 TC
FBR
FBR
FNDP 190/M TL MEC