TRACXP Calibration Gas: TXP-T40, Nitrogen, Cylinder, 58 L Cylinder Capacity, Ammonia 50 ppm
The TRACXP TXP-T40 Calibration Gas is a 58 L cylinder of nitrogen with an ammonia 50 ppm gas mixture, designed for use with the TXP-T40 fixed gas detector. This calibration gas enables accurate sensor verification…
SKU 3G-OTH-551887
- 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
- Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
- Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Butuh bantuan pemasangan atau rekayasa?
Ajukan pertanyaan
Deskripsi Produk
The TRACXP TXP-T40 Calibration Gas is a 58 L cylinder of nitrogen with an ammonia 50 ppm gas mixture, designed for use with the TXP-T40 fixed gas detector. This calibration gas enables accurate sensor verification and span adjustment for ammonia detection, supplied as a complete cylinder assembly (MPN 37-0031-2244-2).
Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.
Pertanyaan yang Sering Diajukan
What is TRACXP TXP-T40 calibration gas used for?
The TRACXP TXP-T40 calibration gas is used to verify sensor accuracy and perform span adjustment on TXP-T40 fixed gas detectors that monitor ammonia. It contains 50 ppm ammonia in a nitrogen background, supplied in a 58 L cylinder (MPN 37-0031-2244-2).
What are the specifications of TRACXP TXP-T40 calibration gas?
The TRACXP TXP-T40 calibration gas is a 58 L cylinder with a background gas of nitrogen and a gas mixture of ammonia at 50 ppm. It is designed for use with the TXP-T40 fixed gas detector. The manufacturer part number is 37-0031-2244-2.
Where to buy TRACXP TXP-T40 calibration gas worldwide?
3G Electric supplies the TRACXP TXP-T40 calibration gas (MPN 37-0031-2244-2) to customers worldwide. We handle full logistics, customs clearance, and delivery, ensuring you receive the correct 58 L cylinder with 50 ppm ammonia in nitrogen for your TXP-T40 detector.
How to use TRACXP TXP-T40 calibration gas for sensor adjustment?
Connect the TRACXP TXP-T40 calibration gas cylinder to the detector’s calibration port, then follow the TXP-T40 manual to initiate span adjustment. Apply the 50 ppm ammonia mixture at the specified flow rate until the sensor stabilizes. Always use fresh gas and proper regulators.
TRACXP Produk
3G Electric memasok TRACXP calibration gases for fixed gas detectors. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.









