FBR X G OSR 2003 TXC R S - Burners & Combustion
FBRBurners & Combustion

FBR X G OSR 2003 TXC R S

Pembakar diesel FBR X G OSR 2003 TXC R S adalah pembakar industri satu tahap (single stage) yang dirancang khusus untuk ketel uap besi cor (cast iron boilers). Dengan rentang daya termal 14,2–36,7 kW dan aliran bahan…

SKU 3G-FBR-00100

Merek
FBR
Item
X G OSR 2003 TXC R S
Kategori
Burners & Combustion
UNSPSC
40101834 — Burners
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Distributor Resmi
Langsung dari OEM
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

FBR
Weight
11 kg
stage
Single stage for cast iron boilers
fuel type
Light oil
nozzle mm
77
fan motor w
100
preheater w
30-110
power kw max
36.7
power kw min
14.2
flow kg h max
3.1
flow kg h min
1.2
ip protection
IP 40
noisiness dba
57-59
electrical supply
1
power supply info
50Hz
current absorption a
1
thermal power mcal h
20.4-51
nominal electric power w
220
max combustion air temp c
60

Konten Lembar Data

LIGHT-OIL BURNERS ONE STAGE SERIES G 2003 SK070039_A_en LIGHT-OIL BURNERS ONE STAGE SERIES G 2003 G 0HR - G 0SR - G 0H - G 0S - G 1HR - G 1SR - G 1H - G 1S Light-oil burners single stage. They are composed by: aluminium frame, protection cover with noise reduction plate, combustion head specific for cast iron boilers and combustion chambers with small length. Micro adjustment of the head, high efficiency and high flame stability. Compact overall dimensions and disposition rationalized of the components with accessibility facilitated for the operations of setting and maintenance. In the versions H hydraulic device of closing air shutter. In the versions R preheater with control of temperature for soft and sicure ignitions also at low temperatures. On demand specific versions: kerosene, biodiesel. Complete of connector 7 poles, flange and gasket for installation on boiler, nozzle, flexible pipes, line filter. Fig. 1 G 0S Fig. 2 G 1S G 0HR - G 0SR - G 0H - G 0S - G 1HR - G 1SR - G 1H - G 1S LIGHT-OIL BURNERS ONE STAGE SERIES G 2003 SK070039_A_en TECHNICAL DATA G 0HR - G 0SR - G 0H - G 0S - G 1HR - G 1SR - G 1H - G 1S MODEL G 0HR G 0H G 1HR G 1H G 0SR G 0S G 1SR G 1S Flow min. - max. * [kg/h] 1.2-3.1 2.0-3.3 2.0-5.0 2.0-5.0 Thermal power min. - max. * [Mcal/h] 12.2-31.6 20.4-33.7 20.4-51 20.4-51 Thermal power min. - max. * [kW] 14.2-36.7 23.7-39.1 23.7-59.2 23.7-59.2 Fuel: LIGHT-OIL 1.5°E at 20°C = 6.2 cSt = 35 sec Redwood N°1 Intermitted working operation (min. 1 stop every 24 hours) one stage Environmental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max. temperature combustion air [°C] 60 Nominal electric power [W] 190 120 220 130 Fan motor [W] 90 90 100 100 Nominal current absorption [A] 0.9 0.6 1 0.6 Pre-heater [W] 30-110 - 30-110 - Power supply: 1N~230V - 50Hz Electric protection degree: IP 40 Noisiness min. - max. ** [dBA] 56-58 56-58 57-59 57-59 Burner weight [kg] 9 9 11 11 * Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** Measured sonorous pressure in the combustion laboratory, with burner on operation on beta boiler to 1m of distance (UNI EN ISO 3746). OPERATING RANGE DIAGRAM G 0HR - G 0SR - G 0H - G 0S - G 1HR - G 1SR - G 1H - G 1S Fig. 3 X = Thermal power Y = Pression in the combustion chamber The firing rates has been obtained based on test boilers in accordance with EN267 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non-compliance, contact the manufacturer. G 0HR - G 0SR - G 0H - G 0S - G 1HR - G 1SR - G 1H - G 1S LIGHT-OIL BURNERS ONE STAGE SERIES G 2003 SK070039_A_en DIMENSIONS [MM] Fig. 4 Dimensions G 0HR - G 0SR - G 0H - G 0S - G 1HR - G 1SR - G 1H - G 1S MODEL A B C D E F G H I G0...2003 137 137 240 83 223 169 15 150 150 G1...2003 157 170 275 83 265 210 15 150 150 * See "flame tube length" BOILER PLATE * Suggested dimension of connection between burner and generator. Fig. 5 Boiler plate MODEL L min L* L max M N min N* N max G0...2003 mm 130 150 170 M8 90 110 130 G1...2003 mm 130 150 170 M8 90 110 130 FLAME TUBE LENGTH Flame tube length must be selected based on the specifications supplied by boiler manufacturer and, in any case, it must be greater than the thickness of the boiler door included its insulation. In case of boilers with flame inversion or front flue combustion chambers, it is necessary to insulate the area between the flame tube and front door with refractory material. This protection material must not impede flame tube extraction. MODEL TC TL ** G0...2003 mm 112 152 G1...2003 mm 112 152 ** For different flame lengths, please contact our Technical-Sales Department. G 0HR - G 0SR - G 0H - G 0S - G 1HR - G 1SR - G 1H - G 1S LIGHT-OIL BURNERS ONE STAGE SERIES G 2003 SK070039_A_en PRODUCT SPECIFICATION SHORT DESCRIPTION Light-oil burners one stage. DETAILED SPECIFICATION Light-oil burner one stage composed by: • Aluminium frame; • Combustion head specific for cast iron boilers and combustion chambers with small length; • Micro adjustment of the head, high efficiency and high flame stability; • Protection cover with noise reduction plate; • Flange and insulating gasket for fixing at boiler; • Single-phase power supply; • Photoresistance for flame detection; • IP 40 electric protection level. CONFORMING TO: • CE rules; • 2014/30/UE Directive E.M.C.; • 2014/35/UE Directive L.V.; • 2014/68/EU Directive M.D.; • 97/23/CE Directive P.E.D.; • Reference rules: EN267 (liquid fuel) - EN746-2 (industrial thermoprocessing equipment). STANDARD EQUIPMENT • Flexible hoses for connection; • Line filter; • Isomart gasket; • Nozzle; • Flange with insulating gasket; • Burner nameplate; • Warranty; • Instruction handbook for installation, use and maintenance. The illustrations and data here shown are indicative. F.B.R. Bruciatori S.r.l. reserves the right to bring, without any obligation of warning, any changes that would be appropriate to the continuing development of their products. G 0HR - G 0SR - G 0H - G 0S - G 1HR - G 1SR - G 1H - G 1S
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

FBR Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

Pembakar diesel FBR X G OSR 2003 TXC R S adalah pembakar industri satu tahap (single stage) yang dirancang khusus untuk ketel uap besi cor (cast iron boilers). Dengan rentang daya termal 14,2–36,7 kW dan aliran bahan bakar 1,2–3,1 kg/jam, unit ini dilengkapi pemanas awal (preheater) 30–110 W untuk pengapian yang stabil pada suhu rendah. Perlindungan IP 40 dan tingkat kebisingan 57–59 dBA menjadikannya pilihan andal untuk aplikasi pembakaran minyak ringan di sektor peralatan industri.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Untuk apa FBR X G OSR 2003 TXC R S digunakan?

Pembakar diesel FBR X G OSR 2003 TXC R S digunakan sebagai pembakar satu tahap (single stage) pada ketel uap besi cor (cast iron boilers) dengan bahan bakar minyak ringan (light oil). Cocok untuk aplikasi peralatan pembakaran di industri yang membutuhkan daya termal 14,2–36,7 kW dan aliran bahan bakar 1,2–3,1 kg/jam.

Apa spesifikasi teknis FBR X G OSR 2003 TXC R S?

Spesifikasi teknis meliputi: daya termal 14,2–36,7 kW, aliran bahan bakar 1,2–3,1 kg/jam, motor kipas 100 W, pemanas awal 30–110 W, proteksi IP 40, kebisingan 57–59 dBA, berat 11 kg, dan suplai listrik 1N~230V 50Hz. Dilengkapi nosel 77 mm untuk pembakaran minyak ringan.

Bagaimana cara memilih FBR X G OSR 2003 TXC R S yang tepat?

Pilih FBR X G OSR 2003 TXC R S jika Anda membutuhkan pembakar satu tahap untuk ketel uap besi cor dengan daya termal antara 14,2–36,7 kW. Pastikan suplai listrik 1N~230V 50Hz dan bahan bakar minyak ringan sesuai spesifikasi. Kehadiran pemanas awal (preheater) 30–110 W memastikan pengapian stabil pada suhu rendah.

Di mana beli FBR X G OSR 2003 TXC R S di Indonesia?

Anda dapat membeli FBR X G OSR 2003 TXC R S melalui 3G Electric, distributor resmi yang memasok dan mengirimkan peralatan industri ini ke seluruh Indonesia. Kami menangani logistik dan bea cukai untuk memastikan produk sampai ke lokasi Anda. Hubungi kami untuk minta penawaran.

Digunakan dalam

Aplikasi umum untuk FBR
Hospitality and commercial HVAC — cast-iron boiler plants in hotels and shopping complexes
Pharmaceutical and biotech process heat — gas-fired burners with ATEX gas trains for classified-zone requirements
Medical-waste and bio-hazard incineration — FGP progressive dual-fuel systems
Food and beverage steam boilers — single-stage G-series for continuous-duty cycles
Marine and offshore platforms — IP54-rated X-series for high-humidity marine operations

FBR Produk

3G Electric memasok FBR burners & combustion. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Rangkaian Gas & Katup Gas Transformator Pengapian Kontrol Pembakar Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
X G OSR 2003 TC R S
FBR
X G OSR 2003 TC R S
X G OSR LX TC R S
FBR
X G OSR LX TC R S
X G OSR LX TXC R S
FBR
X G OSR LX TXC R S
X G os 2003 TXC S
FBR
X G os 2003 TXC S
X G os LX TXC S
FBR
X G os LX TXC S
X G 1SR 2003 TC R S
FBR
X G 1SR 2003 TC R S

Lainnya dari FBR

Lihat semua FBR suku cadang
FBR
FBR
K 350/M TL
FBR
FBR
G 0S LX TC
FBR
FBR
G X5 F TL
FBR
FBR
G X4.22 LX TL
FBR
FBR
K X6/M EL EVO TL
FGP 1500/M TL MEC
FBR
FGP 1500/M TL MEC
FGP 75/2 LX TC
FBR
FGP 75/2 LX TC
FBR
FBR
K 250/M TL EL