Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

FBR FGP 50/M TL EVO SA - Burners & Combustion
FBRBurners & Combustion

FBR FGP 50/M TL EVO SA

Pembakar industri FBR FGP 50/M TL EVO SA adalah light-oil burner dua tahap progresif atau modulating (dengan kit modulasi opsional dan probe PID) yang dirancang untuk aplikasi ketel uap dan peralatan pembakaran…

SKU 3G-FBR-00068

Merek
FBR
Item
FGP 50/M TL EVO SA
Kategori
Burners & Combustion
UNSPSC
40101834 — Burners
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Distributor Resmi
Langsung dari OEM
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

FBR
Weight
150 kg
stage
Progressive and modulating
fuel type
Light oil
nozzle mm
250
fan motor w
0.55
power kw max
630
power kw min
124
flow kg h max
53
flow kg h min
10.5
ip protection
IP44
noisiness dba
78-82.5
pump motor kw
0.37
electrical supply
3
power supply info
3~400V,1/N~230V-50Hz
current absorption a
1.2
thermal power mcal h
107/204-542
nominal electric power w
1.1
max combustion air temp c
60

Konten Lembar Data

LIGHT-OIL฀BURNERS฀TWO฀STAGES฀PROGRESSIVE฀ SK070003_A_gb OR฀MODULATING BRUCIATORIDIGASOLIOBISTADIO PROGRESSIVI OMODULANTI FGP฀50/M฀EVO Light-oil฀burners฀two฀stages฀progressive฀or฀modulating฀operation฀(if฀equipped฀with฀addition฀of฀optional฀ modulation฀kit฀PID฀and฀probe;฀to฀guarantee฀an฀ideal฀proportionality฀of฀the฀power฀supplied฀to฀the฀thermal฀ load). Composed฀฀by:฀fan฀at฀high฀pressurisation฀at฀reverse฀blades฀and฀combustion฀head฀with฀adjustment฀at฀high฀ efficiency฀and฀฀high฀flame฀stability. Compact฀฀overall฀dimensions฀and฀disposition฀rationalized฀of฀the฀components฀with฀accessibility฀facilitated฀for฀ the฀operations฀of฀setting฀and฀maintenance. Complete฀฀of฀nozzle,฀flexible฀pipes฀and฀line฀filter. Complete฀฀of฀flange฀and฀gasket฀for฀installation฀on฀generator. Fig. 1 FGP฀50/M฀EVO FGP฀50/M฀EVO LIGHT-OIL฀BURNERS฀TWO฀STAGES฀PROGRESSIVE฀ SK070003_A_gb OR฀MODULATING TECHNICAL฀DATA฀FGP฀50/M฀EVO MODEL FGP฀50/M฀EVO Thermal฀power฀min.฀1°st.฀/฀min.฀2°st.฀-฀max.฀2°st.฀* [Mcal/h] 107/204-542 Thermal฀power฀min.฀1°st.฀/฀min.฀2°st.฀-฀max.฀2°st.฀* [kW] 124/237-630 LIGHT-OIL฀flow฀min.฀1°st.฀/฀min.฀2°st.฀-฀max.฀2°st.฀* [kg/h] 10.5/20-53 Fuel: LIGHT-OIL฀1.5°E฀at฀20°C฀=฀6.2฀cSt฀=฀35฀sec฀Redwood฀N°1 Intermitted฀working฀operation฀(min.฀1฀stop฀every฀24฀hours)฀two฀stages฀progressive฀or฀modulating Environmental฀conditions฀operation฀/฀storage: -15...+40°C฀/฀-20...+70°C,฀rel.฀humidity฀max.฀80% Max.฀temperature฀combustion฀air [°C] 60 Nominal฀electric฀power [kW] 1.1 Fan฀motor [kW] 0.55 Pump฀motor [kW] 0.37 Nominal฀fan฀motor฀current฀absorption [A] 1.4 Nominal฀pump฀motor฀current฀absorption [A] 1.2 Nominal฀auxiliary฀absorption [A] 0.6 Power฀supply: 3~400V,1/N~230V-50Hz Electric฀protection฀degree: IP44 * Reference฀conditions:฀Environment฀temperature฀20°C฀-฀Barometric฀pressure฀1013฀mbars฀-฀Altitude฀0฀metre฀(sea฀level). OPERATING฀RANGE฀DIAGRAM฀FGP฀50/M฀EVO <mbar> 13 11 9 7 5 3 )*30(92 1 -1 0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 <kW> Fig. 2 X฀=฀Thermal฀power฀Y฀=฀Pression฀in฀the฀combustion฀chamber The฀firing฀rates฀has฀been฀obtained฀based฀on฀test฀boilers฀in฀accordance฀with฀EN267฀standards฀and฀are฀indicative฀of฀matching฀the฀burner฀to฀the฀ boiler.฀For฀the฀correct฀operation฀of฀the฀burner,฀combustion฀chamber฀dimensions฀must฀be฀in฀accordance฀with฀current฀regulation.฀In฀case฀of฀non- compliance,฀contact฀the฀manufacturer. FGP฀50/M฀EVO LIGHT-OIL฀BURNERS฀TWO฀STAGES฀PROGRESSIVE฀ SK070003_A_gb OR฀MODULATING DIMENSIONS฀[MM] O A B F P D E TC - TL * C Fig. 3 Dimensions฀FGP฀50/M฀EVO MODEL A B C D E F O P FGP฀50/M฀EVO 329 274 746 150 416.5 100 207 200 C2:฀Overall฀dimension฀with฀the฀burner฀out฀in฀position฀of฀maintenance. * see฀"flame฀tube฀length" FGP฀50/M฀EVO LIGHT-OIL฀BURNERS฀TWO฀STAGES฀PROGRESSIVE฀ SK070003_A_gb OR฀MODULATING BOILER฀PLATE * Suggested฀dimension฀of฀connection฀between฀burner and฀generator. Fig. 4 Boiler฀plate MODEL M N min N max L฀min L฀* L฀max FGP฀50/M฀EVO mm M10 205 226 160 160 180 FLAME฀TUBE฀LENGTH Flame฀tube฀length฀must฀be฀selected฀based฀on฀the฀specifications฀supplied฀by฀boiler฀manufacturer฀and,฀in฀any฀case,฀it must฀be฀greater฀than฀the฀thickness฀of฀the฀boiler฀door฀included฀its฀insulation. In฀case฀of฀boilers฀with฀flame฀inversion฀or฀front฀flue฀combustion฀chambers,฀it฀is฀necessary฀to฀insulate฀the฀area฀between the฀flame฀tube฀and฀front฀door฀with฀refractory฀material.฀This฀protection฀material฀must฀not฀impede฀flame฀tube฀ extraction. MODEL TC TL ** FGP฀50/M฀EVO mm 250 335 **฀For฀different฀flame฀lengths,฀please฀contact฀our฀Technical-Sales฀Department. FGP฀50/M฀EVO LIGHT-OIL฀BURNERS฀TWO฀STAGES฀PROGRESSIVE฀ SK070003_A_gb OR฀MODULATING BURNER฀SIGNAL฀DESCRIPTION In฀the฀picture฀below฀there฀are฀indicated฀all฀the฀signalation฀present฀on฀the฀burner: 2 1 Fig. 5 Burner฀signal฀description฀ LEGEND 1) ON/OFF฀button 2) Reset฀from฀lockout฀button฀+฀status฀lamp The multicolor signal lamp in the lockout reset button (pos.2) is the key indicating element for visual diagnostics and interface diagnostics. In normal operation, the different operating states are indicated in the form of color codes; please refer to electrical device handbook supplied with the present instructions. After a non-alterable lockout, the red signal lamp in the lockout reset button (pos.2) lights up. By pressing the lockout reset button (pos.2) for more than 3 seconds, the visual diagnostics of the cause of fault can be activated; please refer to electrical device handbook supplied with the present instructions. For close the diagnostics mode and for switch on the burner again, it is necessary to reset the burner control. Press the lockout reset button (pos.2) for about 1 second (<3 seconds). After a non-alterable lockout, the red signal lamp in the lockout reset button (pos.2) lights up. For reset the control box press the lockout reset button (pos.2) for about 1 second (<3 seconds). FGP฀50/M฀EVO LIGHT-OIL฀BURNERS฀TWO฀STAGES฀PROGRESSIVE฀ SK070003_A_gb OR฀MODULATING PRODUCT฀SPECIFICATION SHORT฀DESCRIPTION Light-oil฀burners฀two฀stages฀progressive฀(hi-low฀flame)฀or฀modulating฀(PID฀fully฀modulating)฀if฀equipped฀with฀ addition฀of฀optional฀modulation฀kit฀and฀probe. DETAILED฀SPECIFICATION Light-oil฀burner฀two฀stages฀progressive฀(hi-low฀flame)฀or฀modulating฀(PID฀fully฀modulating)฀if฀equipped฀with฀addition฀ of฀optional฀modulation฀kit฀and฀probe;฀composed฀by: • Fan฀at฀high฀pressurisation฀at฀reverse฀blades; • Combustion฀head฀with฀adjustment฀at฀high฀performance฀and฀elevated฀flame฀stability; • Flange฀and฀insulating฀gasket฀for฀fixing฀at฀boiler; • Three-phase฀power฀supply; • Photodiode฀for฀flame฀detection; • IP฀44฀electric฀protection฀level; • Servomotor฀for฀air฀shutter฀and฀for฀the฀pressure฀regulator; • Easy฀extraction฀of฀combustion฀head฀without฀get฀off฀the฀burners฀by฀bolier; • Maximum฀light-oil฀pressure฀switch฀to฀stop฀the฀burner฀in฀case฀of฀the฀light-oil฀pressure฀on฀the฀return฀is฀higher฀then฀the฀set฀point value; • Safety฀air฀pressure฀switch฀to฀stop฀the฀burner฀in฀lock-out฀(by฀stopping฀the฀pump฀motor)฀in฀case฀of฀failed฀or฀anomalous฀fan operation; • Dedicated฀motor฀for฀the฀activation฀of฀the฀light-oil฀pump; • Set฀up฀for฀the฀additional฀specific฀kit฀that฀transforms฀burner฀operation฀as฀modulating฀i.e.฀the฀modulating฀kit฀allows฀to฀supply any฀power฀between฀the฀minimun฀and฀the฀maximum฀value฀based฀on฀instantaneous฀loading฀request. CONFORMING฀TO: • CE฀rules; • 2014/30/UE฀Directive฀E.M.C.; • 2014/35/UE฀Directive฀L.V.; • 2006/42/CE฀-฀2006/42/EG฀-฀2006/42/EC฀Directive฀M.D.; • Directive฀PED฀ 2014/68/UE฀ (ART.4,PAR.3); • Reference฀rules:฀EN267฀(liquid฀fuel)฀-฀EN746-2฀(industrial฀thermoprocessing฀equipment). STANDARD฀EQUIPMENT • Flexible hoses for connection; • Line filter; • Isomart gasket; • Nozzle; • Flange with insulating gasket; • Burner nameplate; • Warranty; • Instruction handbook for installation, use and maintenance. OPTIONAL • Power฀modulating฀kits฀for฀temperatures; • Power฀modulating฀kits฀for฀pressures; • Temperature฀probe฀0°C-400°C฀(PT฀100฀a฀0°฀C); • Temperature฀probe฀0°C-350°C฀(J฀probe); • Temperature฀probe฀0°C-1200°C฀(K฀probe); • Pressure฀probe฀0-3฀bar,฀0-6฀bar.฀0-16฀bar,฀0-20฀bar,฀0-30฀bar; • Noise฀protection. The฀illustrations฀and฀data฀here฀shown฀are฀indicative.฀F.B.R.฀Bruciatori฀S.r.l.฀reserves฀the฀right฀to฀bring,฀without฀any฀obligation฀of฀warning,฀any฀changes฀that฀would฀be฀appropriate฀to฀the฀continuing฀development฀of฀their฀products. FGP฀50/M฀EVO
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

FBR Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

Pembakar industri FBR FGP 50/M TL EVO SA adalah light-oil burner dua tahap progresif atau modulating (dengan kit modulasi opsional dan probe PID) yang dirancang untuk aplikasi ketel uap dan peralatan pembakaran. Dengan rentang daya termal 124–630 kW dan aliran light oil 10,5–53 kg/jam, unit ini dilengkapi fan motor 0,55 kW, pump motor 0,37 kW, perlindungan IP44, dan suplai listrik 3~400V,1/N~230V-50Hz. Cocok untuk kebutuhan pembakar industri di Indonesia.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Apa spesifikasi FBR FGP 50/M TL EVO SA?

Pembakar industri FBR FGP 50/M TL EVO SA memiliki daya termal 124–630 kW, aliran light oil 10,5–53 kg/jam, fan motor 0,55 kW, pump motor 0,37 kW, perlindungan IP44, dan suplai listrik 3~400V,1/N~230V-50Hz. Berat 150 kg, nozzle 250 mm, dan suhu udara pembakaran maksimal 60°C.

Untuk apa FBR FGP 50/M TL EVO SA digunakan?

Pembakar ini digunakan untuk aplikasi pembakaran light oil pada ketel uap dan peralatan pembakaran industri. Operasinya dua tahap progresif atau modulating (dengan kit modulasi opsional dan probe PID) untuk menyesuaikan daya termal 124–630 kW secara proporsional terhadap beban termal.

Bagaimana cara memilih FBR FGP 50/M TL EVO SA?

Pilih berdasarkan daya termal yang dibutuhkan (124–630 kW), aliran light oil (10,5–53 kg/jam), dan suplai listrik (3~400V,1/N~230V-50Hz). Pastikan lingkungan operasi -15...+40°C dan kelembaban maksimal 80%. Untuk operasi modulating, tambahkan kit modulasi PID dan probe opsional.

Di mana beli FBR FGP 50/M TL EVO SA di Indonesia?

Anda dapat membeli FBR FGP 50/M TL EVO SA melalui 3G Electric, distributor resmi yang memasok dan mengirimkan peralatan industri ini ke Indonesia. Kami menangani logistik dan bea cukai untuk memastikan produk sampai ke lokasi Anda.

Digunakan dalam

Aplikasi umum untuk FBR
Hospitality and commercial HVAC — cast-iron boiler plants in hotels and shopping complexes
Pharmaceutical and biotech process heat — gas-fired burners with ATEX gas trains for classified-zone requirements
Medical-waste and bio-hazard incineration — FGP progressive dual-fuel systems
Food and beverage steam boilers — single-stage G-series for continuous-duty cycles
Marine and offshore platforms — IP54-rated X-series for high-humidity marine operations

FBR Produk

3G Electric memasok FBR burners & combustion. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Rangkaian Gas & Katup Gas Transformator Pengapian Kontrol Pembakar Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
FGP 50/M TC EVO SA
FBR
FGP 50/M TC EVO SA
FGP 100/M TL EVO SA
FBR
FGP 100/M TL EVO SA
FGP 130/M TL EVO SA
FBR
FGP 130/M TL EVO SA
FGP 130/M TC EVO SA
FBR
FGP 130/M TC EVO SA
FGP 100/M TC EVO SA
FBR
FGP 100/M TC EVO SA
FGP 50/2 TL EVO 3 SI
FBR
FGP 50/2 TL EVO 3 SI

Lainnya dari FBR

Lihat semua FBR suku cadang
FBR
FBR
K 350/M TL
FBR
FBR
G 0S LX TC
FBR
FBR
G X5 F TL
FBR
FBR
G X4.22 LX TL
FBR
FBR
K X6/M EL EVO TL
FGP 1500/M TL MEC
FBR
FGP 1500/M TL MEC
FGP 75/2 LX TC
FBR
FGP 75/2 LX TC
FBR
FBR
K 250/M TL EL