Konten Lembar Data
LIGHT-OIL BURNERS TWO STAGES PROGRESSIVE OR
SK070071_A_en_FGP750-1800
MODULATING
LIGHT-OIL BURNERS TWO STAGES PROGRESSIVE OR MODULATING
FGP 750/M - FGP 1000/M - FGP 1300/M - FGP 1500/M - FGP 1800/M
Burners for light-oil two stages progressive (hi-low flame) or modulating (PID fully modulating) if equipped with
addition of optional modulation kit and probe.
They are composed by: fan at high pressurisation and combustion head with adjustment at high efficiency and high
flame stability.
Compact overall dimensions and disposition rationalized of the components with accessibility facilitated for the
operations of setting and maintenance.
The adoption of strong metal components makes the burner durable also in heavy duty conditions.
Complete of nozzle, flexible pipes and line filter.
Complete of flange and gasket for installation on generator.
Available with mechanical cam or with electronic cam.
Fig. 1 FGP 750/M
FGP 750/M - FGP 1000/M - FGP 1300/M - FGP 1500/M - FGP 1800/M
LIGHT-OIL BURNERS TWO STAGES PROGRESSIVE OR
SK070071_A_en_FGP750-1800
MODULATING
TECHNICAL DATA
MODEL FGP 750/M FGP 1000/M FGP 1300/M FGP 1500/M FGP 1800/M
Thermal power min.1°st. / min.2°st. - max.2°st. * [Mcal/h] 968/3400-7500 968/3400- 998/3600- 998/3600- 1416/5000-
10000 11500 13000 15000
Thermal power min.1°st. / min.2°st. - max.2°st. * [kW] 1125/3953- 1125/3953- 1160/4186- 1160/4186- 1647/5814-
8721 11628 13372 15116 17442
Light-oil flow min.1°st. / min.2°st. - max.2°st. * [kg/h] 97/333-735 97/333-980 100/353-1127 100/353-1274 142/490-1471
Fuel: Light-oil 1.5°E at 20°C = 6.2 cSt = 35 sec Redwood N°1
Intermitted working operation (min. 1 stop every 24 hours) two stages progressive or modulating
Enviromental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80%
Max. temperature combustion air [°C] 60 60 60 60 60
Nominal electric power [kW] 27 35 41.5 49.5 61
Fan motor [kW] 22 30 37 45 55
Pump motor [kW] 3 4 4 4 5.5
Fan motor absorption [A] 43 55.5 64.2 77.6 94
Pump motor absorption [A] 6.7 8.6 8.6 8.6 11.7
Power supply 3~400V - 1/N~230V-50Hz
Degree of electric protection IP40
Noiseness ** max. [dB(A)] 84-88 86-92 90-93 92-95 94-98
* Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level)
** Measured sonorous pressure in the laboratory combustion, with functional burner on beta boiler to 1 metre of distance (UNI EN ISO 3746 law).
OPERATING RANGE DIAGRAM
Fig. 2 X = Thermal power Y = Pression in the combustion chamber
The firing rates has been obtained based on test boilers in accordance with EN267 standards and are indicative of matching the burner to the boiler.
For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non-compliance,
contact the manufacturer.
FGP 750/M - FGP 1000/M - FGP 1300/M - FGP 1500/M - FGP 1800/M
LIGHT-OIL BURNERS TWO STAGES PROGRESSIVE OR
SK070071_A_en_FGP750-1800
MODULATING
BURNER DIMENSIONS [MM]
Fig. 3 Burner dimensions
MODEL A B C D E F H TL
FGP 750/M 600 654 845 448 832 1453 22 685
FGP 1000/M 600 654 845 468 832 1453 22 685
FGP 1300/M 600 654 845 500 832 1453 22 655
FGP 1500/M 600 654 845 500 832 1453 22 655
FGP 1800/M 700 664 880 540 945 1560 22 685
BOILER PLATE
The dimensions of the boiler plate (threaded holes or
studs) must be as indicated in the drawing.
Fig. 4 Boiler plate
MODEL M L min L* max P min P max
FGP 750/M mm M16 707 778 460 540
FGP 1000/M mm M16 707 778 480 540
FGP 1300/M mm M16 707 778 520 540
FGP 1500/M mm M16 707 778 520 540
FGP 1800/M mm M18 806 890 550 630
* Suggested dimension.
FGP 750/M - FGP 1000/M - FGP 1300/M - FGP 1500/M - FGP 1800/M
LIGHT-OIL BURNERS TWO STAGES PROGRESSIVE OR
SK070071_A_en_FGP750-1800
MODULATING
PRODUCT SPECIFICATION
SHORT DESCRIPTION
Light-oil burners two stages progressive (hi-low flame) or modulating (PID fully modulating) if equipped with addition
of optional modulation kit and probe.
DETAILED SPECIFICATION
Light-oil burner two stages progressive (hi-low flame) or modulating (PID fully modulating) if equipped with addition
of optional modulation kit and probe; composed by:
• Frame made of steel;
• Centrifugal fan at high pressurization with reverse curved blades at low noisiness;
• Combustion head with adjustment at high performance and elevated flame stability equipped with inox steel blast tube and
steel flame disc;
• Easy extraction of combustion head without get off the burners by bolier;
• Flange and insulating gasket for fixing at boiler/furnace;
• Control box for control and supervision of burner;
• Photoresistance for flame detection;
• Three-phase power supply;
• Fan motor start-up made by delta/star system FGP 750/M - FGP 1000/M;
• Fan motor start-up made by soft-starter system FGP 1300/M - FGP 1500/M - FGP 1800/M;
• IP40 electric protection level;
• Safety air pressure switch to stop the fuel pump in case of failed or anomalous fan operation, causing the lockout of the burner;
• Servomotor for air shutter and for the fuel pressure regulator;
• Mobile shutter with total closure when idle for minimize the energetic losses related at boiler cooling;
• Light-oil gear pump operated by specific electric motor;
• Nozzle assembly with magnet to control inlet/return needle nozzle;
• Maximum light-oil pressure switch to stop the burner in case of the light-oil pressure on the return is higher then the set point
value;
• Set up for the additional specific kit that transforms burner operation as modulating i.e.the modulating kit allows to supply any
power between the minimum and maximum value based on instantaneous loading request.
CONFORMING TO:
• CE rules;
• 2014/30/UE Directive E.M.C.;
• 2014/35/UE Directive L.V.;
• 2014/68/EU Directive M.D.;
• 97/23/CE Directive P.E.D.;
• Reference rules: EN267 (liquid fuel) - EN746-2 (industrial thermoprocessing equipment).
STANDARD EQUIPMENT
• Flexible hoses for connection;
• Line filter;
• Isomart gasket;
• Nozzle;
• Flange with insulating gasket;
• Burner nameplate;
• Warranty;
• Instruction handbook for installation, use and maintenance.
OPTIONAL
• Power modulating kits for temperatures;
• Power modulating kits for pressures;
• Temperature probe 0°C-400°C (PT 100 a 0° C);
• Temperature probe 0°C-1200°C (K probe);
• Pressure probe 0-3 bar, 0-6 bar. 0-16 bar, 0-20 bar, 0-30 bar;
• Noise protection;
• Minimum light-oil pressure switch.
•
The illustrations and data here shown are indicative. F.B.R. Bruciatori S.r.l. reserves the right to bring, without any obligation of warning, any changes that would be appropriate to the continuing development of their products.
FGP 750/M - FGP 1000/M - FGP 1300/M - FGP 1500/M - FGP 1800/M