Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

FBR FGP 100/M TC EVO SA - Burners & Combustion
FBRBurners & Combustion

FBR FGP 100/M TC EVO SA

FBR FGP 100/M TC EVO SA adalah pembakar (burner) bahan bakar minyak ringan (light oil) dua tahap progresif atau modulasi (PID) yang dirancang untuk aplikasi industri. Dengan rentang daya termal 190–1186 kW dan laju…

SKU 3G-FBR-00078

Merek
FBR
Item
FGP 100/M TC EVO SA
Kategori
Burners & Combustion
UNSPSC
40101834 — Burners
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Distributor Resmi
Langsung dari OEM
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

FBR
Weight
150 kg
stage
Progressive and modulating
fuel type
Light oil
nozzle mm
235
fan motor w
1.5
power kw max
1186
power kw min
190
flow kg h max
100
flow kg h min
16.1
ip protection
IP40
noisiness dba
82-83.6
pump motor kw
0.75
electrical supply
3
power supply info
3~400V,1/N~230V-50Hz
current absorption a
1.6
thermal power mcal h
164.2/408-1020
nominal electric power w
2.4
max combustion air temp c
60

Konten Lembar Data

LIGHT-OIL BURNERS SK070090_C_en TWO STAGES PROGRESSIVE OR MODULATING FGP 75/M - FGP 100/M EVO - FGP 130/M EVO - FGP 160/M Burners for light-oil two stages progressive (hi-low flame) or modulating (PID fully modulating) if equipped with addition of optional modulation kit and probe. Composed by: air blower at high pressurisation and combustion head with adjustment at high efficiency and high flame stability. Compact overall dimensions and disposition rationalized of the components with accessibility facilitated for the easy setting and maintenance. Complete of nozzle, flexible pipes and line filter. Complete of flange and gasket for installation on generator. Fig. FGP 130/M EVO FGP 75/M - FGP 100/M EVO - FGP 130/M EVO - FGP 160/M LIGHT-OIL BURNERS SK070090_C_en TWO STAGES PROGRESSIVE OR MODULATING TECHNICAL DATA FGP 75/M - FGP 100/M EVO MODEL FGP 75/M FGP 100/M EVO Thermal power min. 1°st. /min. 2°st. - max. 2°st. * [Mcal/h] 178/357-816 164.2/408-1020 Thermal power min. 1°st. /min. 2°st. - max. 2°st. * [kW] 207/415-949 190/474-1186 Flow min. 1°st. / min. 2°st. - max. 2°st. * [kg/h] 17.5/35-80 16.1/40-100 Fuel: LIGHT-OIL 1.5°E at 20°C = 6.2 cSt = 35 sec Redwood N°1 Intermitted working operation (min. 1 stop every 24 hours) two stages progressive or modulating Environmental conditions operation / storage: -15...+40°C฀/฀-20...+70°C,฀rel. humidity max.฀80% Max. temperature combustion air [°C] 60 60 Nominal electric power [kW] 2.2 2.4 Fan motor [kW] 1.5 1.5 Pump motor [kW] 0.55 0.75 Nominal fan motor current absorption [A] 3.4 4.5 Nominal pump motor current absorption [A] 1.6 1.6 Nominal auxiliary absorption [A] 0.82 0.82 Power supply: 3~400V,1/N~230V-50Hz Electric protection degree: IP40 IP40 Noiseness min. - max. ** [dBA] 78-82.5 82-83.6 * Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** Measured sonorous pressure in the laboratory combustion, with functional burner on beta boiler to 1 metre of distance (UNI EN ISO 3746 law). FGP 75/M - FGP 100/M EVO - FGP 130/M EVO - FGP 160/M LIGHT-OIL BURNERS SK070090_C_en TWO STAGES PROGRESSIVE OR MODULATING OPERATING RANGE DIAGRAM FGP 75/M [mbar] FGP 75/M [kW] Fig. X = Thermal power Y = Pression in the combustion chamber The firing rates has been obtained based on test boilers in accordance with EN267 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non- compliance, contact the manufacturer. OPERATING RANGE DIAGRAM FGP 100/M EVO [mbar] [kW] Fig. X = Thermal power Y = Pression in the combustion chamber The firing rates has been obtained based on test boilers in accordance with EN267 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non- compliance, contact the manufacturer. FGP 75/M - FGP 100/M EVO - FGP 130/M EVO - FGP 160/M LIGHT-OIL BURNERS SK070090_C_en TWO STAGES PROGRESSIVE OR MODULATING TECHNICAL DATA FGP 130/M EVO MODEL FGP 130/M EVO Thermal power min. 1°st. /min. 2°st. - max. 2°st. * [Mcal/h] 289/612-1326 Thermal power min. 1°st. /min. 2°st. - max. 2°st. * [kW] 336/712-1542 Flow min. 1°st. / min. 2°st. - max. 2°st. * [kg/h] 28.3/60-130 Fuel: LIGHT-OIL 1.5°E at 20°C = 6.2 cSt = 35 sec Redwood N°1 Intermitted working operation (min. 1 stop every 24 hours) two stages progressive or modulating Environmental conditions operation / storage: -15...+40°C฀/฀-20...+70°C,฀rel. humidity max.฀80% Max. temperature combustion air [°C] 60 Nominal electric power [kW] 3 Fan motor [kW] 2.2 Pump motor [kW] 0.75 Nominal fan motor current absorption [A] 4.35 Nominal pump motor current absorption [A] 1.6 Nominal auxiliary absorption [A] 0.82 Power supply: 3~400V,1/N~230V-50Hz Electric protection degree: IP40 Noiseness min. - max. ** [dBA] 78-82.5 * Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** Measured sonorous pressure in the laboratory combustion, with functional burner on beta boiler to 1 metre of distance (UNI EN ISO 3746 law). OPERATING RANGE DIAGRAM FGP 130/M EVO [mbar] 17 15 13 11 9 7 5 3 1 -1 0 200 400 600 800 1000 1200 1400 1600 1800 2000 [kW] Fig. X = Thermal power Y = Pression in the combustion chamber The firing rates has been obtained based on test boilers in accordance with EN267 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non- compliance, contact the manufacturer. FGP 75/M - FGP 100/M EVO - FGP 130/M EVO - FGP 160/M LIGHT-OIL BURNERS SK070090_C_en TWO STAGES PROGRESSIVE OR MODULATING TECHNICAL DATA FGP 160/M MODEL FGP 160/M Thermal power min. 1°st. /min. 2°st. - max. 2°st. * [Mcal/h] 374/765-1634 Thermal power min. 1°st. /min. 2°st. - max. 2°st. * [kW] 435/889-1900 Flow min. 1°st. / min. 2°st. - max. 2°st. * [kg/h] 36.7/75-160 Fuel: LIGHT-OIL 1.5°E at 20°C = 6.2 cSt = 35 sec Redwood N°1 Intermitted working operation (min. 1 stop every 24 hours) two stages progressive or modulating Environmental conditions operation / storage: -15...+40°C฀/฀-20...+70°C,฀rel. humidity max.฀80% Max. temperature combustion air [°C] 60 Nominal electric power [kW] 5 Fan motor [kW] 4 Pump motor [kW] 0.75 Nominal fan motor current absorption [A] 7.45 Nominal pump motor current absorption [A] 2 Nominal auxiliary absorption [A] 0.82 Power supply: 3~400V,1/N~230V-50Hz Electric protection degree: IP40 Noiseness min. - max. ** [dBA] 84.4-85.4 * Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** Measured sonorous pressure in the laboratory combustion, with functional burner on beta boiler to 1 metre of distance (UNI EN ISO 3746 law). OPERATING RANGE DIAGRAM FGP 160/M [mbar] 17 15 13…
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

FBR Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

FBR FGP 100/M TC EVO SA adalah pembakar (burner) bahan bakar minyak ringan (light oil) dua tahap progresif atau modulasi (PID) yang dirancang untuk aplikasi industri. Dengan rentang daya termal 190–1186 kW dan laju aliran 16,1–100 kg/jam, unit ini dilengkapi motor kipas 1,5 kW dan motor pompa 0,75 kW pada suplai listrik 3~400V, 1/N~230V-50Hz. Perlindungan IP40 dan tingkat kebisingan 82–83,6 dBA menjadikannya pilihan andal untuk sistem pembakaran di Indonesia.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Apa spesifikasi teknis FBR FGP 100/M TC EVO SA?

FBR FGP 100/M TC EVO SA memiliki daya termal 190–1186 kW, laju aliran 16,1–100 kg/jam, motor kipas 1,5 kW, motor pompa 0,75 kW, suplai listrik 3~400V/1/N~230V-50Hz, proteksi IP40, dan tingkat kebisingan 82–83,6 dBA.

Untuk apa FBR FGP 100/M TC EVO SA digunakan?

Pembakar ini digunakan untuk pembakaran minyak ringan pada ketel uap industri, tungku, atau generator panas. Dengan mode dua tahap progresif atau modulasi (PID), ia cocok untuk aplikasi yang memerlukan kontrol nyala api presisi dan efisiensi tinggi.

Bagaimana cara memilih antara mode progresif dan modulasi pada FBR FGP 100/M TC EVO SA?

Mode progresif (hi-low flame) cocok untuk beban yang relatif stabil, sedangkan mode modulasi (PID) memerlukan kit modulasi opsional dan probe untuk penyesuaian nyala api secara kontinu. Pilih berdasarkan kebutuhan kontrol suhu atau tekanan yang lebih presisi.

Di mana beli FBR FGP 100/M TC EVO SA di Indonesia?

Anda dapat membeli FBR FGP 100/M TC EVO SA melalui 3G Electric, distributor resmi yang memasok dan mengirimkan peralatan industri ini ke seluruh Indonesia. Kami menangani logistik dan bea cukai untuk memastikan produk sampai ke lokasi Anda.

Apa saja komponen yang disertakan dengan FBR FGP 100/M TC EVO SA?

Pembakar ini dilengkapi nosel, pipa fleksibel, filter saluran, flensa, dan gasket untuk pemasangan pada generator. Semua komponen sudah terpasang untuk memudahkan instalasi dan perawatan.

Digunakan dalam

Aplikasi umum untuk FBR
Hospitality and commercial HVAC — cast-iron boiler plants in hotels and shopping complexes
Pharmaceutical and biotech process heat — gas-fired burners with ATEX gas trains for classified-zone requirements
Medical-waste and bio-hazard incineration — FGP progressive dual-fuel systems
Food and beverage steam boilers — single-stage G-series for continuous-duty cycles
Marine and offshore platforms — IP54-rated X-series for high-humidity marine operations

FBR Produk

3G Electric memasok FBR burners & combustion. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Rangkaian Gas & Katup Gas Transformator Pengapian Kontrol Pembakar Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
FGP 130/M TC EVO SA
FBR
FGP 130/M TC EVO SA
FGP 100/M TL EVO SA
FBR
FGP 100/M TL EVO SA
FGP 50/M TC EVO SA
FBR
FGP 50/M TC EVO SA
FGP 130/M TL EVO SA
FBR
FGP 130/M TL EVO SA
FGP 50/M TL EVO SA
FBR
FGP 50/M TL EVO SA
FGP 100/2 TC EVO SI
FBR
FGP 100/2 TC EVO SI

Lainnya dari FBR

Lihat semua FBR suku cadang
FBR
FBR
K 350/M TL
FBR
FBR
G 0S LX TC
FBR
FBR
G X5 F TL
FBR
FBR
G X4.22 LX TL
FBR
FBR
K X6/M EL EVO TL
FGP 1500/M TL MEC
FBR
FGP 1500/M TL MEC
FGP 75/2 LX TC
FBR
FGP 75/2 LX TC
FBR
FBR
K 250/M TL EL