Dwyer 3G-CBM-02370 — Technical Specifications
Dwyer Current transmitter CCT 50-203
Technical Specifications
| Parameter | Value |
|---|---|
| Accuracy | 1% |
| Response Time | 250 ms at 90% |
| Certifications | CE, cUL, UL |
| Current Ranges | 10/20/50 A or 100/150/200 A |
| Humidity Range | 0 to 95% (non-condensing) |
| Output Current | 4 to 20 mA |
| Product Series | CCT40/50, CCT60/70 |
| Frequency Range | 10 to 400 Hz |
| Housing Material | ABS plastic |
| Isolation Voltage | 2000 V |
| Core Type Option 1 | Solid core |
| Core Type Option 2 | Split core (openable) |
| Power Supply Option 1 | Self-powered |
| Power Supply Option 2 | 15 to 42 VDC loop-powered |
| Output Voltage Option 1 | 0 to 5 V |
| Output Voltage Option 2 | 0 to 10 V |
| Current Rating Adjustable | up to 200 A |
| Housing Flammability Rating | UL 94 V-O |
| Operating Temperature Range | -30 to +70 °C |
Physical & Shipping Data
| Weight | 0.4 kg |
| Length | 120 mm |
| Width | 80 mm |
| Height | 70 mm |
| Country of Origin | France |