Konten Lembar Data
LIGHT-OIL BURNERS TWO STAGES PROGRESSIVE OR
SK070071_B_en
MODULATING
LIGHT-OIL BURNERS TWO STAGES PROGRESSIVE OR MODULATING
FGP 650/M
Burners for light-oil two stages progressive (hi-low flame) or modulating (PID fully modulating) if equipped with
addition of optional modulation kit and probe.
They are composed by: fan at high pressurisation and combustion head with adjustment at high efficiency and high
flame stability.
Compact overall dimensions and disposition rationalized of the components with accessibility facilitated for the
operations of setting and maintenance.
The adoption of strong metal components makes the burner durable also in heavy duty conditions.
Complete of nozzle, flexible pipes and line filter.
Complete of flange and gasket for installation on generator.
Available with mechanical cam or with electronic cam.
Fig. 1 Fig. 2
Fig. 3 Fig. 4
FGP 650/M
LIGHT-OIL BURNERS TWO STAGES PROGRESSIVE OR
SK070071_B_en
MODULATING
TECHNICAL DATA
MODEL FGP 650/M
Thermal power min.1°st. / min.2°st. - max.2°st. * [Mcal/h] 847/3000-6500
Thermal power min.1°st. / min.2°st. - max.2°st. * [kW] 986/3488-7558
Light-oil flow min.1°st. / min.2°st. - max.2°st. * [kg/h] 85/294-637
Fuel: Light-oil 1.5°E at 20°C = 6.2 cSt = 35 sec Redwood N°1
Intermitted working operation (min. 1 stop every 24 hours) two stages progressive or modulating
Enviromental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max.
80%
Max. temperature combustion air [°C] 60
Nominal electric power [kW] 21
Fan motor [kW] 18.5
Pump motor [kW] 2.2
Fan motor absorption [A] 36.2
Pump motor absorption [A] 5.4
Nominal absorption burner auxiliary [A] 4
Power supply 3~400V - 1/N~230V-50Hz
Degree of electric protection IP40
Noiseness ** max. [dB(A)] 85
Burner weight [kg] 540
* Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level)
** Measured sonorous pressure in the laboratory combustion, with functional burner on beta boiler to 1 metre of distance (UNI EN ISO 3746 law).
OPERATING RANGE DIAGRAM
[mbar]
[kW]
[Mcal/h]
Fig. 5 X = Thermal power Y = Pression in the combustion chamber
The firing rates has been obtained based on test boilers in accordance with EN267 standards and are indicative of matching the burner to the boiler.
For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non-compliance,
contact the manufacturer.
FGP 650/M
LIGHT-OIL BURNERS TWO STAGES PROGRESSIVE OR
SK070071_B_en
MODULATING
BURNER DIMENSIONS [MM]
Fig. 6 Burner dimensions
MODEL A B C D E F H TL
FGP 650/M 600 654 845 439 833 1453 22 721
BOILER PLATE
The dimensions of the boiler plate (threaded holes or
studs) must be as indicated in the drawing.
Fig. 7 Boiler plate
MODEL M N min N* N Max L min L max
FGP 650/M mm M16 707 778 778 460 540
* Suggested dimension.
FGP 650/M
LIGHT-OIL BURNERS TWO STAGES PROGRESSIVE OR
SK070071_B_en
MODULATING
PRODUCT SPECIFICATION
SHORT DESCRIPTION
Light-oil burners two stages progressive (hi-low flame) or modulating (PID fully modulating) if equipped with addition
of optional modulation kit and probe.
DETAILED SPECIFICATION
Light-oil burner two stages progressive (hi-low flame) or modulating (PID fully modulating) if equipped with addition
of optional modulation kit and probe; composed by:
• Frame made of steel;
• Centrifugal fan at high pressurization with reverse curved blades at low noisiness;
• Combustion head with adjustment at high performance and elevated flame stability equipped with inox steel blast tube and
steel flame disc;
• Easy extraction of combustion head without get off the burners by bolier;
• Flange and insulating gasket for fixing at boiler/furnace;
• Control box for control and supervision of burner;
• Photoresistance for flame detection;
• Three-phase power supply;
• Fan motor start-up made by delta/star system;
• IP40 electric protection level;
• Safety air pressure switch to stop the fuel pump in case of failed or anomalous fan operation, causing the lockout of the burner;
• Servomotor for air shutter and for the fuel pressure regulator;
• Mobile shutter with total closure when idle for minimize the energetic losses related at boiler cooling;
• Light-oil gear pump operated by specific electric motor;
• Nozzle assembly with magnet to control inlet/return needle nozzle;
• Maximum light-oil pressure switch to stop the burner in case of the light-oil pressure on the return is higher then the set point
value;
• Set up for the additional specific kit that transforms burner operation as modulating i.e.the modulating kit allows to supply any
power between the minimum and maximum value based on instantaneous loading request.
CONFORMING TO:
• CE rules;
• 2014/30/UE Directive E.M.C.;
• 2014/35/UE Directive L.V.;
• 2014/68/EU Directive M.D.;
• 97/23/CE Directive P.E.D.;
• Reference rules: EN267 (liquid fuel) - EN746-2 (industrial thermoprocessing equipment).
STANDARD EQUIPMENT
• Flexible hoses for connection;
• Line filter;
• Isomart gasket;
• Nozzle;
• Flange with insulating gasket;
• Burner nameplate;
• Warranty;
• Instruction handbook for installation, use and maintenance.
OPTIONAL
• Power modulating kits for temperatures;
• Power modulating kits for pressures;
• Temperature probe 0°C-400°C (PT 100 a 0° C);
• Temperature probe 0°C-1200°C (K probe);
• Pressure probe 0-3 bar, 0-6 bar. 0-16 bar, 0-20 bar, 0-30 bar;
• Noise protection.
The illustrations and data here shown are indicative. F.B.R. Bruciatori S.r.l. reserves the right to bring, without any obligation of warning, any changes that would be appropriate to the continuing development of their products.
FGP 650/M