Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

FBR FGP 130/2 TL EVO SI - Burners & Combustion
FBRBurners & Combustion

FBR FGP 130/2 TL EVO SI

FBR FGP 130/2 TL EVO SI adalah pembakar diesel dua tahap (2 stages) yang dirancang untuk bahan bakar minyak ringan (light oil) dengan rentang daya termal 336–1542 kW dan laju alir bahan bakar 28,3–130 kg/jam…

SKU 3G-FBR-00080

Merek
FBR
Item
FGP 130/2 TL EVO SI
Kategori
Burners & Combustion
UNSPSC
40101834 — Burners
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Distributor Resmi
Langsung dari OEM
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

FBR
Weight
15.5 kg
stage
2 stages
fuel type
Light oil
nozzle mm
210
fan motor w
250
power kw max
1542
power kw min
336
flow kg h max
130
flow kg h min
28.3
ip protection
IP 40
noisiness dba
68-69
electrical supply
3
power supply info
1N~230V
current absorption a
1.6
thermal power mcal h
289/612-1326
nominal electric power w
300
max combustion air temp c
60

Konten Lembar Data

LIGHT-OIL BURNERS TWO STAGES FGP 130/2 EVO - FGP 160/2 Light-oil burners two stages. Composed by: fan at high pressurisation, combustion head with adjustment at high efficiency and high flame stability and hydraulic system of regulation combustive air on the two stages of flame. The burners are equipped with two motors : air blower motor + pump motor. Compact overall dimensions and disposition rationalized of the components with accessibility facilitated for the operations of setting and maintenance. Complete of 2 nozzles, 2 flexible hoses and line filter. Complete of flange and gasket for installation on generator. FGP 130/2 EVO - FGP 160/2 LIGHT-OIL BURNERS TWO STAGES TECHNICAL DATA FGP 130/2 EVO MODEL FGP 130/2 EVO Flow min. 1°st. / min. 2°st. - max. 2°st. * [kg/h] 28.3/60-130 Thermal power min. 1°st. / min. 2°st. - [Mcal/h] 289/612-1326 max. 2°st. * Thermal power min. 1°st. / min. 2°st. - [kW] 336/712-1542 max. 2°st. * Fuel: LIGHT-OIL 1.5°E at 20°C = 6.2 cSt = 35 sec Redwood N°1 Intermitted working operation (min. 1 stop every 24 hours) two stages Environmental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max. temperature combustion air [°C] 60 Nominal electric power [kW] 3 Fan motor [kW] 2.2 Pump motor [kW] 0.37 Nominal fan motor current absorption [A] 4.35 Nominal pump motor current absorption [A] 1.2 Nominal auxiliary absorption [A] 0.82 Power supply: 3~400V, 1N~230V - 50Hz Electric protection degree: IP 40 Noisiness ** min-max [dBA] 83.8-84 Weight *** [kg] 84 * Reference conditions : Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** Measured sonourous pressure in the combustion lab, with funcional burner on beta boiler in a distance of 1 m (UNI EN ISO 3746). *** For burner with long head add 2 kg. OPERATING RANGE DIAGRAM FGP 130/2 EVO [mbar] 18 16 14 12 10 8 6 4 2 0 200 400 600 800 1000 1200 1400 1600 [kW] Fig. X = Therma l power Y = Pression in the combustion chamber The firing rates has been obtained based on test boilers in accordance with EN267 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non-compliance, contact the manufacturer. FGP 130/2 EVO - FGP 160/2 LIGHT-OIL BURNERS TWO STAGES TECHNICAL DATA FGP 160/2 MODEL FGP 160/2 Flow min. 1°st. / min. 2°st. - max. 2°st. * [kg/h] 36.7/75-160 Thermal power min. 1°st. / min. 2°st. - [Mcal/h] 374/765-1634 max. 2°st. * Thermal power min. 1°st. / min. 2°st. - [kW] 435/889-1900 max. 2°st. * Fuel: LIGHT-OIL 1.5°E at 20°C = 6.2 cSt = 35 sec Redwood N°1 Intermitted working operation (min. 1 stop every 24 hours) two stages Environmental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max. temperature combustion air [°C] 60 Nominal electric power [kW] 5 Fan motor [kW] 4 Pump motor [kW] 0.37 Nominal fan motor current absorption [A] 7.45 Nominal pump motor current absorption [A] 1.2 Nominal auxiliary absorption [A] 0.82 Power supply: 3~400V, 1N~230V - 50Hz Electric protection degree: IP 40 Noisiness ** min-max [dBA] 84.4-85.4 Weight *** [kg] 95 * Reference conditions :Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** Measured sonourous pressure in the combustion lab, with funcional burner on beta boiler in a distance of 1 m (UNI EN ISO 3746). *** For burner with long head add 2 kg. OPERATING RANGE DIAGRAM FGP 160/2 [mbar] 18 16 14 12 10 8 6 4 2 0 200 400 600 800 1000 1200 1400 1600 1800 2000 [kW] Fig. X = Therma l power Y = Pression in the combustion chamber The firing rates has been obtained based on test boilers in accordance with EN267 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non-compliance, contact the manufacturer. FGP 130/2 EVO - FGP 160/2 LIGHT-OIL BURNERS TWO STAGES DIMENSIONS [MM] G F H C I E A B TC - TL * D1-D2 J K Fig. Dimensions FGP 130/2 EVO - FGP 160/2 MODEL A B C D1 D2 E F G H I J K FGP 130/2 EVO 383 343 209 803 1383 510 211 320 320 20 183 40 FGP 160/2 383 405 209 803 1383 510 211 320 320 20 183 40 * see "flame tube length" D2: Overall dimension with the burner out in position of maintenance. FGP 130/2 EVO - FGP 160/2 LIGHT-OIL BURNERS TWO STAGES BOILER PLATE * Suggested dimension of connection between burner and generator. Fig. Boiler plate MODEL L min L max M N min N* N max FGP 130/2 EVO mm 340 368 M14 230 230 250 FGP 160/2 mm 340 368 M14 230 230 250 FLAME TUBE LENGTH Flame tube length must be selected based on the specifications supplied by boiler manufacturer and, in any case, it must be greater than the thickness of the boiler door included its insulation. In case of boilers with flame inversion or front flue combustion chambers, it is necessary to insulate the area between the flame tube and front door with refractory material. This protection material must not impede flame tube extraction. MODEL TC TL ** FGP 130/2 EVO mm 210 400 FGP 160/2 mm 210 400 ** For different flame lengths, please contact our Technical-Sales Department. FGP 130/2 EVO - FGP 160/2 LIGHT-OIL BURNERS TWO STAGES BURNER SIGNAL DESCRIPTION In the picture below there are indicated all the signalation present on the burner: 1 2 Fig. Burner signal description LEGEND 1) ON/OFF button 2) Reset from lockout button + status lamp The multicolor signal lamp in the lockout reset button (pos.2) is the key indicating element for visual diagnostics and interface diagnostics. In normal operation, the different operating states are indicated in the form of color codes; please refer to electrical device handbook supplied with the present instructions. After a non-alterable lockout, the red signal lamp in the lockout reset button (pos.2) lights up. By pressing the lockout reset button (pos.2) for more than 3 seconds, the visual diagnostics of the cause of fault can be activated; please refer to electrical device handbook supplied with the present instructions. For close the diagnostics mode and for switch on the burner again, it is necessary to reset the burner control. Press the lockout reset button (pos.2) for about 1 second (<3 seconds). After a non-alterable lockout, the red signal lamp in the lockout reset button (pos.2) lights up. For reset the control box press the lockout reset button (pos.2) for about 1 second (<3 seconds). FGP 130/2 EVO - FGP 160/2 LIGHT-OIL BURNERS TWO STAGES PRODUCT SPECIFICATION SHORT DESCRIPTION Light-oil burners two stages. DETAILED SPECIFICATION Light-oil burner two stages composed by: • Fan at high pressurisation at reverse blades FGP130/2 EVO; • Fan at high pressurisation FGP160/2; • Combustion head with adjustment at high performance and elevated flame stability; • Flange and…
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

FBR Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

FBR FGP 130/2 TL EVO SI adalah pembakar diesel dua tahap (2 stages) yang dirancang untuk bahan bakar minyak ringan (light oil) dengan rentang daya termal 336–1542 kW dan laju alir bahan bakar 28,3–130 kg/jam. Dilengkapi motor kipas 250 W, motor pompa terintegrasi, serta perlindungan IP 40, unit ini cocok untuk aplikasi ketel uap industri yang membutuhkan pembakaran stabil dan efisien. Cari suku cadang pembakar FBR? Produk ini tersedia sebagai bagian dari rangkaian pembakar industri FBR.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Apa spesifikasi teknis FBR FGP 130/2 TL EVO SI?

FBR FGP 130/2 TL EVO SI adalah pembakar diesel dua tahap dengan daya termal 336–1542 kW, laju alir bahan bakar 28,3–130 kg/jam, motor kipas 250 W, motor pompa 0,37 kW, dan perlindungan IP 40. Berat unit 15,5 kg dan suplai listrik 1N~230V 50Hz.

Untuk apa FBR FGP 130/2 TL EVO SI digunakan?

Pembakar ini digunakan pada ketel uap industri, pemanas thermal oil, dan sistem pembakaran lain yang memerlukan dua tahap nyala api. Bahan bakar yang digunakan adalah minyak ringan (light oil) dengan viskositas maksimal 6,2 cSt pada 20°C.

Bagaimana cara memilih nozzle untuk FBR FGP 130/2 TL EVO SI?

Pembakar ini dilengkapi 2 nozzle dengan ukuran 210 mm. Pemilihan nozzle harus disesuaikan dengan kapasitas aliran bahan bakar yang dibutuhkan, yaitu antara 28,3 kg/jam (tahap pertama) hingga 130 kg/jam (tahap kedua maksimal). Pastikan nozzle sesuai spesifikasi pabrikan FBR.

Di mana beli FBR FGP 130/2 TL EVO SI di Indonesia?

Anda dapat membeli FBR FGP 130/2 TL EVO SI melalui 3G Electric, distributor resmi yang memasok dan mengirimkan peralatan pembakaran ke seluruh Indonesia. Kami menangani logistik dan bea cukai sehingga produk sampai ke lokasi proyek Anda dengan aman.

Apa perbedaan FGP 130/2 TL EVO SI dengan model FGP 160/2?

Kedua model sama-sama pembakar dua tahap untuk light oil. FGP 130/2 TL EVO SI memiliki kapasitas aliran maksimal 130 kg/jam dan daya termal hingga 1542 kW, sedangkan FGP 160/2 memiliki kapasitas lebih besar. Detail spesifik FGP 160/2 dapat dilihat di datasheet terpisah.

Digunakan dalam

Aplikasi umum untuk FBR
Hospitality and commercial HVAC — cast-iron boiler plants in hotels and shopping complexes
Pharmaceutical and biotech process heat — gas-fired burners with ATEX gas trains for classified-zone requirements
Medical-waste and bio-hazard incineration — FGP progressive dual-fuel systems
Food and beverage steam boilers — single-stage G-series for continuous-duty cycles
Marine and offshore platforms — IP54-rated X-series for high-humidity marine operations

FBR Produk

3G Electric memasok FBR burners & combustion. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Rangkaian Gas & Katup Gas Transformator Pengapian Kontrol Pembakar Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
FGP 130/2 TC EVO SI
FBR
FGP 130/2 TC EVO SI
FGP 100/2 TL EVO SI
FBR
FGP 100/2 TL EVO SI
FGP 100/2 LX TL EVO SI
FBR
FGP 100/2 LX TL EVO SI
FGP 50/2 TL EVO 3 SI
FBR
FGP 50/2 TL EVO 3 SI
FGP 130/M TL EVO SA
FBR
FGP 130/M TL EVO SA
FGP 55/2 LX TL EVO SI
FBR
FGP 55/2 LX TL EVO SI

Lainnya dari FBR

Lihat semua FBR suku cadang
FBR
FBR
K 350/M TL
FBR
FBR
G 0S LX TC
FBR
FBR
G X5 F TL
FBR
FBR
G X4.22 LX TL
FBR
FBR
K X6/M EL EVO TL
FGP 1500/M TL MEC
FBR
FGP 1500/M TL MEC
FGP 75/2 LX TC
FBR
FGP 75/2 LX TC
FBR
FBR
K 250/M TL EL