Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

FBR FGP 75/M TC SA - Burners & Combustion
FBRBurners & Combustion

FBR FGP 75/M TC SA

Pembakar industri FBR FGP 75/M TC SA adalah light-oil burner dua tahap progresif (hi-low flame) atau modulating (PID fully modulating) jika dilengkapi kit modulasi opsional dan probe. Dengan daya termal maksimum 949…

SKU 3G-FBR-00076

Merek
FBR
Item
FGP 75/M TC SA
Kategori
Burners & Combustion
UNSPSC
40101834 — Burners
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Distributor Resmi
Langsung dari OEM
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

FBR
Weight
150 kg
stage
Progressive and modulating
fuel type
Light oil
nozzle mm
250
fan motor w
1.5
power kw max
949
power kw min
207
flow kg h max
80
flow kg h min
17.5
ip protection
IP40
noisiness dba
78-82.5
pump motor kw
0.55
electrical supply
3
power supply info
3~400V,1/N~230V-50Hz
current absorption a
1.6
thermal power mcal h
178/357-816
nominal electric power w
2.2
max combustion air temp c
60

Konten Lembar Data

LIGHT-OIL BURNERS SK070090_C_en TWO STAGES PROGRESSIVE OR MODULATING FGP 75/M - FGP 100/M EVO - FGP 130/M EVO - FGP 160/M Burners for light-oil two stages progressive (hi-low flame) or modulating (PID fully modulating) if equipped with addition of optional modulation kit and probe. Composed by: air blower at high pressurisation and combustion head with adjustment at high efficiency and high flame stability. Compact overall dimensions and disposition rationalized of the components with accessibility facilitated for the easy setting and maintenance. Complete of nozzle, flexible pipes and line filter. Complete of flange and gasket for installation on generator. Fig. FGP 130/M EVO FGP 75/M - FGP 100/M EVO - FGP 130/M EVO - FGP 160/M LIGHT-OIL BURNERS SK070090_C_en TWO STAGES PROGRESSIVE OR MODULATING TECHNICAL DATA FGP 75/M - FGP 100/M EVO MODEL FGP 75/M FGP 100/M EVO Thermal power min. 1°st. /min. 2°st. - max. 2°st. * [Mcal/h] 178/357-816 164.2/408-1020 Thermal power min. 1°st. /min. 2°st. - max. 2°st. * [kW] 207/415-949 190/474-1186 Flow min. 1°st. / min. 2°st. - max. 2°st. * [kg/h] 17.5/35-80 16.1/40-100 Fuel: LIGHT-OIL 1.5°E at 20°C = 6.2 cSt = 35 sec Redwood N°1 Intermitted working operation (min. 1 stop every 24 hours) two stages progressive or modulating Environmental conditions operation / storage: -15...+40°C฀/฀-20...+70°C,฀rel. humidity max.฀80% Max. temperature combustion air [°C] 60 60 Nominal electric power [kW] 2.2 2.4 Fan motor [kW] 1.5 1.5 Pump motor [kW] 0.55 0.75 Nominal fan motor current absorption [A] 3.4 4.5 Nominal pump motor current absorption [A] 1.6 1.6 Nominal auxiliary absorption [A] 0.82 0.82 Power supply: 3~400V,1/N~230V-50Hz Electric protection degree: IP40 IP40 Noiseness min. - max. ** [dBA] 78-82.5 82-83.6 * Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** Measured sonorous pressure in the laboratory combustion, with functional burner on beta boiler to 1 metre of distance (UNI EN ISO 3746 law). FGP 75/M - FGP 100/M EVO - FGP 130/M EVO - FGP 160/M LIGHT-OIL BURNERS SK070090_C_en TWO STAGES PROGRESSIVE OR MODULATING OPERATING RANGE DIAGRAM FGP 75/M [mbar] FGP 75/M [kW] Fig. X = Thermal power Y = Pression in the combustion chamber The firing rates has been obtained based on test boilers in accordance with EN267 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non- compliance, contact the manufacturer. OPERATING RANGE DIAGRAM FGP 100/M EVO [mbar] [kW] Fig. X = Thermal power Y = Pression in the combustion chamber The firing rates has been obtained based on test boilers in accordance with EN267 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non- compliance, contact the manufacturer. FGP 75/M - FGP 100/M EVO - FGP 130/M EVO - FGP 160/M LIGHT-OIL BURNERS SK070090_C_en TWO STAGES PROGRESSIVE OR MODULATING TECHNICAL DATA FGP 130/M EVO MODEL FGP 130/M EVO Thermal power min. 1°st. /min. 2°st. - max. 2°st. * [Mcal/h] 289/612-1326 Thermal power min. 1°st. /min. 2°st. - max. 2°st. * [kW] 336/712-1542 Flow min. 1°st. / min. 2°st. - max. 2°st. * [kg/h] 28.3/60-130 Fuel: LIGHT-OIL 1.5°E at 20°C = 6.2 cSt = 35 sec Redwood N°1 Intermitted working operation (min. 1 stop every 24 hours) two stages progressive or modulating Environmental conditions operation / storage: -15...+40°C฀/฀-20...+70°C,฀rel. humidity max.฀80% Max. temperature combustion air [°C] 60 Nominal electric power [kW] 3 Fan motor [kW] 2.2 Pump motor [kW] 0.75 Nominal fan motor current absorption [A] 4.35 Nominal pump motor current absorption [A] 1.6 Nominal auxiliary absorption [A] 0.82 Power supply: 3~400V,1/N~230V-50Hz Electric protection degree: IP40 Noiseness min. - max. ** [dBA] 78-82.5 * Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** Measured sonorous pressure in the laboratory combustion, with functional burner on beta boiler to 1 metre of distance (UNI EN ISO 3746 law). OPERATING RANGE DIAGRAM FGP 130/M EVO [mbar] 17 15 13 11 9 7 5 3 1 -1 0 200 400 600 800 1000 1200 1400 1600 1800 2000 [kW] Fig. X = Thermal power Y = Pression in the combustion chamber The firing rates has been obtained based on test boilers in accordance with EN267 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non- compliance, contact the manufacturer. FGP 75/M - FGP 100/M EVO - FGP 130/M EVO - FGP 160/M LIGHT-OIL BURNERS SK070090_C_en TWO STAGES PROGRESSIVE OR MODULATING TECHNICAL DATA FGP 160/M MODEL FGP 160/M Thermal power min. 1°st. /min. 2°st. - max. 2°st. * [Mcal/h] 374/765-1634 Thermal power min. 1°st. /min. 2°st. - max. 2°st. * [kW] 435/889-1900 Flow min. 1°st. / min. 2°st. - max. 2°st. * [kg/h] 36.7/75-160 Fuel: LIGHT-OIL 1.5°E at 20°C = 6.2 cSt = 35 sec Redwood N°1 Intermitted working operation (min. 1 stop every 24 hours) two stages progressive or modulating Environmental conditions operation / storage: -15...+40°C฀/฀-20...+70°C,฀rel. humidity max.฀80% Max. temperature combustion air [°C] 60 Nominal electric power [kW] 5 Fan motor [kW] 4 Pump motor [kW] 0.75 Nominal fan motor current absorption [A] 7.45 Nominal pump motor current absorption [A] 2 Nominal auxiliary absorption [A] 0.82 Power supply: 3~400V,1/N~230V-50Hz Electric protection degree: IP40 Noiseness min. - max. ** [dBA] 84.4-85.4 * Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** Measured sonorous pressure in the laboratory combustion, with functional burner on beta boiler to 1 metre of distance (UNI EN ISO 3746 law). OPERATING RANGE DIAGRAM FGP 160/M [mbar] 17 15 13…
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

FBR Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

Pembakar industri FBR FGP 75/M TC SA adalah light-oil burner dua tahap progresif (hi-low flame) atau modulating (PID fully modulating) jika dilengkapi kit modulasi opsional dan probe. Dengan daya termal maksimum 949 kW dan minimum 207 kW, serta laju alir bahan bakar 17,5–80 kg/jam, burner ini cocok untuk aplikasi ketel uap dan pemanas industri. Dilengkapi fan motor 1,5 kW, pump motor 0,55 kW, dan perlindungan IP40, unit ini beroperasi pada suplai listrik 3~400V atau 1/N~230V-50Hz. Cari suku cadang pembakar FBR? Produk ini tersedia sebagai bagian dari peralatan pembakaran untuk kebutuhan industri Anda.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Apa spesifikasi teknis FBR FGP 75/M TC SA?

FBR FGP 75/M TC SA memiliki daya termal 207–949 kW, laju alir bahan bakar 17,5–80 kg/jam, fan motor 1,5 kW, pump motor 0,55 kW, dan perlindungan IP40. Suplai listrik 3~400V atau 1/N~230V-50Hz, dengan suhu udara pembakaran maksimum 60°C.

Untuk apa FBR FGP 75/M TC SA digunakan?

Burner ini digunakan untuk pembakaran light oil pada ketel uap dan pemanas industri. Mendukung operasi dua tahap progresif (hi-low flame) atau modulating (PID fully modulating) dengan kit modulasi opsional dan probe.

Bagaimana cara memilih FBR FGP 75/M TC SA yang tepat?

Pastikan daya termal (207–949 kW) dan laju alir (17,5–80 kg/jam) sesuai kebutuhan. Periksa suplai listrik (3~400V atau 1/N~230V-50Hz) dan suhu udara pembakaran maksimum 60°C. Untuk aplikasi modulating, tambahkan kit modulasi opsional.

Di mana beli FBR FGP 75/M TC SA di Indonesia?

Anda dapat membeli FBR FGP 75/M TC SA melalui 3G Electric, distributor resmi yang memasok dan mengirimkan peralatan pembakaran ini ke seluruh Indonesia. Kami menangani logistik dan bea cukai untuk memastikan produk sampai ke lokasi Anda.

Digunakan dalam

Aplikasi umum untuk FBR
Hospitality and commercial HVAC — cast-iron boiler plants in hotels and shopping complexes
Pharmaceutical and biotech process heat — gas-fired burners with ATEX gas trains for classified-zone requirements
Medical-waste and bio-hazard incineration — FGP progressive dual-fuel systems
Food and beverage steam boilers — single-stage G-series for continuous-duty cycles
Marine and offshore platforms — IP54-rated X-series for high-humidity marine operations

FBR Produk

3G Electric memasok FBR burners & combustion. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Rangkaian Gas & Katup Gas Transformator Pengapian Kontrol Pembakar Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
FGP 75/M TL SA
FBR
FGP 75/M TL SA
FGP 75/2 LX TC SI
FBR
FGP 75/2 LX TC SI
FGP 75/2 TC SI
FBR
FGP 75/2 TC SI
FGP 160/M TC SA
FBR
FGP 160/M TC SA
FGP 75/2 TL SI
FBR
FGP 75/2 TL SI
FGP 75/2 LX TL SI
FBR
FGP 75/2 LX TL SI

Lainnya dari FBR

Lihat semua FBR suku cadang
FBR
FBR
K 350/M TL
FBR
FBR
G 0S LX TC
FBR
FBR
G X5 F TL
FBR
FBR
G X4.22 LX TL
FBR
FBR
K X6/M EL EVO TL
FGP 1500/M TL MEC
FBR
FGP 1500/M TL MEC
FGP 75/2 LX TC
FBR
FGP 75/2 LX TC
FBR
FBR
K 250/M TL EL