Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

FBR X G 1.22 2001 SI - Burners & Combustion
FBRBurners & Combustion

FBR X G 1.22 2001 SI

Pembakar diesel FBR X G 1.22 2001 SI adalah pembakar industri dua tahap (2 stages with jump of pressure) yang dirancang untuk bahan bakar light oil. Dengan daya termal maksimum 116 kW dan aliran bahan bakar 9,8…

SKU 3G-FBR-00007

Merek
FBR
Item
X G 1.22 2001 SI
Kategori
Burners & Combustion
UNSPSC
40101834 — Burners
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Distributor Resmi
Langsung dari OEM
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

FBR
Weight
10 kg
stage
2 stages with jump of pressure
fuel type
Light oil
nozzle mm
112
fan motor w
100
power kw max
116
power kw min
47.4
flow kg h max
9.8
flow kg h min
4
ip protection
IP 40
noisiness dba
59-61
electrical supply
1
power supply info
1N~230V
current absorption a
0.7
thermal power mcal h
22.4/40.8-99.9
nominal electric power w
140
max combustion air temp c
60

Konten Lembar Data

LIGHT-OIL BURNERS AT TWO STEPS PRESSURE SK070045_A_en LIGHT-OIL BURNERS AT TWO STEPS PRESSURE G 1.22R - G 1.22 - G 2.22R MAXI - G 2.22 MAXI Light-oil burners at two steps pressure. They are composed by: aluminium frame, protection cover with noise reduction plate, combustion head with micrometric adjustment, high flame stability. Compact overall dimensions and disposition rationalized of the components with accessibility facilitated for the operations of setting and maintenance. In the versions R preheater with control of temperature for soft and sicure ignitions also at low temperatures. Complete of connector 7 poles, flange and gasket for installation on boiler, nozzle, flexible pipes, line filter. Fig. 1 G 1.22R - G 1.22 Fig. 2 G 2.22R MAXI - G 2.22 MAXI G 1.22R - G 1.22 - G 2.22R MAXI - G 2.22 MAXI LIGHT-OIL BURNERS AT TWO STEPS PRESSURE SK070045_A_en TECHNICAL DATA G 1.22R - G 1.22 - G 2.22R MAXI - G 2.22 MAXI MODEL G 1.22R G 1.22 G 2.22R G 2.22 MAXI MAXI Flow min. 1st st. / min. 2nd st. - max. 2nd st. * [kg/h] 1.4/2.0-5.0 2.2/4-9.8 Thermal power min. 1st st. / min. 2nd st. - max. 2nd st. * [Mcal/h] 14.3/20.4-51 22.4/40.8-99.9 Thermal power min. 1st st. / min. 2nd st. - max. 2nd st. * [kW] 16.6/23.7-59.2 26/47.3-116 Fuel: LIGHT-OIL 1.5°E at 20°C = 6.2 cSt = 35 sec Redwood N°1 Intermitted working operation (min. 1 stop every 24 hours) two steps pressure Environmental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max. temperature combustion air [°C] 60 Nominal electric power [W] 220 130 250 140 Fan motor [W] 100 100 100 100 Nominal current absorption [A] 1 0.6 1.1 0.7 Pre-heater [W] 30-110 - 30-110 - Power supply: 1N~230V - 50Hz Electric protection degree: IP 40 Noisiness min. - max. ** [dBA] 57-59 57-59 59-61 59-61 Burner weight *** [kg] 10 10 10 10 * Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** Measured sonorous pressure in the combustion laboratory, with burner on operation on beta boiler to 1m of distance (UNI EN ISO 3746). *** For burner with iron cover (F) add 2 kg to the weight. OPERATING RANGE DIAGRAM G 1.22R - G 1.22 - G 2.22R MAXI - G 2.22 MAXI Fig. 3 X = Thermal power Y = Pression in the combustion chamber The firing rates has been obtained based on test boilers in accordance with EN267 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non-compliance, contact the manufacturer. G 1.22R - G 1.22 - G 2.22R MAXI - G 2.22 MAXI LIGHT-OIL BURNERS AT TWO STEPS PRESSURE SK070045_A_en DIMENSIONS [MM] Fig. 4 Dimensions G 1.22R - G 1.22 - G 2.22R MAXI - G 2.22 MAXI MODEL A B C D E F G H I G 1.22 - G 1.22R 157 170 275 80 265 210 15 150 150 G 2.22 MAXI - G 2.22R MAXI 157 170 275 90 265 210 15 150 150 * See "flame tube length" BOILER PLATE ** Suggested dimension of connection between burner and generator. Fig. 5 Boiler plate MODEL L min L ** L max M N min N ** N max G 1.22 - G 1.22R mm 130 150 170 M8 90 110 130 G 2.22 MAXI - G 2.22R MAXI mm 130 150 170 M8 100 110 130 FLAME TUBE LENGTH Flame tube length must be selected based on the specifications supplied by boiler manufacturer and, in any case, it must be greater than the thickness of the boiler door included its insulation. In case of boilers with flame inversion or front flue combustion chambers, it is necessary to insulate the area between the flame tube and front door with refractory material. This protection material must not impede flame tube extraction. MODEL TC TL *** G 1.22 - G 1.22R mm 112 152 G 2.22 MAXI - G 2.22R MAXI mm 107 147 *** For different flame lengths, please contact our Technical-Sales Department. G 1.22R - G 1.22 - G 2.22R MAXI - G 2.22 MAXI LIGHT-OIL BURNERS AT TWO STEPS PRESSURE SK070045_A_en PRODUCT SPECIFICATION SHORT DESCRIPTION Light-oil burners at two steps pressure. DETAILED SPECIFICATION Light-oil burners at two steps pressure, composed by: • Aluminium frame; • Combustion head with micrometric adjustment, high flame stability and low emissions; • Protection cover with noise reduction plate; • Flange and insulating gasket for fixing at boiler; • Single-phase power supply; • Photoresistance for flame detection; • IP 40 electric protection level; • Hydraulic system of regulation combustive air on the two stages of flame. CONFORMING TO: • CE rules; • 2014/30/UE Directive E.M.C.; • 2014/35/UE Directive L.V.; • 2014/68/EU Directive M.D.; • 97/23/CE Directive P.E.D.; • Reference rules: EN267 (liquid fuel) - EN746-2 (industrial thermoprocessing equipment). STANDARD EQUIPMENT • 7-poles plug for the electrical connections; • Flexible hoses for connection; • Line filter; • Isomart gasket; • Nozzle; • Flange with insulating gasket; • Burner nameplate; • Warranty; • Instruction handbook for installation, use and maintenance. The illustrations and data here shown are indicative. F.B.R. Bruciatori S.r.l. reserves the right to bring, without any obligation of warning, any changes that would be appropriate to the continuing development of their products. G 1.22R - G 1.22 - G 2.22R MAXI - G 2.22 MAXI
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

FBR Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

Pembakar diesel FBR X G 1.22 2001 SI adalah pembakar industri dua tahap (2 stages with jump of pressure) yang dirancang untuk bahan bakar light oil. Dengan daya termal maksimum 116 kW dan aliran bahan bakar 9,8 kg/jam, unit ini cocok untuk aplikasi ketel uap dan tungku industri. Dilengkapi motor kipas 100 W, proteksi IP 40, dan suplai listrik 1N~230V, pembakar ini menawarkan stabilitas nyala api tinggi dan dimensi kompak untuk kemudahan perawatan.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Apa spesifikasi teknis pembakar diesel FBR X G 1.22 2001 SI?

Pembakar diesel FBR X G 1.22 2001 SI memiliki daya termal 47,4–116 kW, aliran bahan bakar 4–9,8 kg/jam, motor kipas 100 W, dan suplai listrik 1N~230V. Proteksi IP 40, tingkat kebisingan 59–61 dBA, dan berat 10 kg. Cocok untuk light oil dengan viskositas 1,5°E pada 20°C.

Untuk apa pembakar diesel FBR X G 1.22 2001 SI digunakan?

Pembakar diesel FBR X G 1.22 2001 SI digunakan pada ketel uap dan tungku industri yang memerlukan pembakaran dua tahap dengan lompatan tekanan. Dirancang untuk bahan bakar light oil, unit ini memberikan stabilitas nyala api tinggi dan pengapian yang lembut berkat sistem dua tahap.

Bagaimana cara memilih pembakar diesel yang tepat untuk boiler?

Pilih pembakar diesel berdasarkan daya termal yang dibutuhkan boiler. FBR X G 1.22 2001 SI memiliki daya 47,4–116 kW dan aliran bahan bakar 4–9,8 kg/jam. Pastikan suplai listrik 1N~230V dan suhu udara pembakaran maksimal 60°C sesuai spesifikasi. Konsultasikan dengan teknisi untuk aplikasi spesifik.

Di mana beli pembakar diesel FBR X G 1.22 2001 SI di Indonesia?

Anda dapat membeli pembakar diesel FBR X G 1.22 2001 SI melalui 3G Electric, distributor resmi yang memasok dan mengirimkan peralatan industri ke seluruh Indonesia. Kami menangani logistik dan bea cukai untuk memastikan produk sampai ke lokasi Anda. Hubungi kami untuk minta penawaran.

Apa keunggulan pembakar diesel dua tahap FBR?

Pembakar diesel FBR X G 1.22 2001 SI menawarkan operasi dua tahap dengan lompatan tekanan, yang meningkatkan efisiensi pembakaran dan mengurangi konsumsi bahan bakar. Dilengkapi kepala pembakar dengan penyesuaian mikrometrik, rangka aluminium, dan penutup pelindung peredam bising untuk operasi yang lebih tenang.

Digunakan dalam

Aplikasi umum untuk FBR
Hospitality and commercial HVAC — cast-iron boiler plants in hotels and shopping complexes
Pharmaceutical and biotech process heat — gas-fired burners with ATEX gas trains for classified-zone requirements
Medical-waste and bio-hazard incineration — FGP progressive dual-fuel systems
Food and beverage steam boilers — single-stage G-series for continuous-duty cycles
Marine and offshore platforms — IP54-rated X-series for high-humidity marine operations

FBR Produk

3G Electric memasok FBR burners & combustion. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Rangkaian Gas & Katup Gas Transformator Pengapian Kontrol Pembakar Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
X G 0S 2001 S
FBR
X G 0S 2001 S
X G 1H 2001 c
FBR
X G 1H 2001 c
X G oH 2001 c
FBR
X G oH 2001 c
X G X3.22 TC SI
FBR
X G X3.22 TC SI
FBR
FBR
X G 2.22 MAXI SI
X G IS 2001 S
FBR
X G IS 2001 S

Lainnya dari FBR

Lihat semua FBR suku cadang
FBR
FBR
K 350/M TL
FBR
FBR
G 0S LX TC
FBR
FBR
G X5 F TL
FBR
FBR
G X4.22 LX TL
FBR
FBR
K X6/M EL EVO TL
FGP 1500/M TL MEC
FBR
FGP 1500/M TL MEC
FGP 75/2 LX TC
FBR
FGP 75/2 LX TC
FBR
FBR
K 250/M TL EL