Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

FBR X G X4/2 TL SI - Burners & Combustion
FBRBurners & Combustion

FBR X G X4/2 TL SI

Pembakar industri diesel FBR X G X4/2 TL SI adalah pembakar dua tahap (two stage) berbahan bakar minyak ringan (light oil) yang dirancang untuk aplikasi ketel uap dan peralatan pembakaran industri. Dengan daya termal…

SKU 3G-FBR-00051

Merek
FBR
Item
X G X4/2 TL SI
Kategori
Burners & Combustion
UNSPSC
40101834 — Burners
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Distributor Resmi
Langsung dari OEM
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

FBR
Weight
15.5 kg
stage
2 stages
fuel type
Light oil
nozzle mm
130
fan motor w
250
power kw max
296
power kw min
94.9
flow kg h max
25
flow kg h min
8
ip protection
IP 40
noisiness dba
68-69
electrical supply
1
power supply info
1N~230V
current absorption a
1.6
thermal power mcal h
82/122-255
nominal electric power w
300
max combustion air temp c
60

Konten Lembar Data

LIGHT-OIL BURNERS TWO STAGE SK070065_B_en G X4/2 - G X5/2 Light-oil burners two stage. They are composed by: two nozzles, aluminium frame, protection cover with noise reduction plate, combustion head with micro adjustment at high efficiency and high flame stability, hydraulic system of regulation combustive air on the two stages of flame. Compact overall dimensions and disposition rationalized of the components with accessibility facilitated for the operations of setting and maintenance. Complete of connector 7 poles, flange and gasket for installation on boiler, nozzles, flexible pipes, line filter. Fig. 1 G X4/2 Fig. 2 G X5/2 G X4/2 - G X5/2 LIGHT-OIL BURNERS TWO STAGE SK070065_B_en TECHNICAL DATA G X4/2 - G X5/2 MODEL G X4/2 G X5/2 Flow 1°st. / min. 2°st. - max. 2°st. * [kg/h] 8/12-25 8.5/15-33.7 Thermal power 1°st. / min. 2°st. - max. 2°st. * [Mcal/h] 82/122-255 87/153-344 Thermal power 1°st. / min. 2°st. - max. 2°st. * [kW] 95/142-296 101/178-400 Fuel: LIGHT-OIL 1.5°E at 20°C = 6.2 cSt = 35 sec Redwood N°1 Intermitted working operation (min. 1 stop every 24 hours) two stage Environmental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max. temperature combustion air [°C] 60 Nominal electric power [W] 300 600 Fan motor [W] 250 450 Nominal current absorption [A] 1.6 2.7 Power supply: 1N~230V - 50Hz Electric protection degree: IP 40 Noisiness min. - max. ** [db(A)] 68-69 71-72 Burner weight *** [kg] 15.5 25 * Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** Measured sonorous pressure in the combustion laboratory, with burner on operation on beta boiler to 1m of distance (UNI EN ISO 3746). *** For burner with cover in steel (F) please add 1 kg to the weight. OPERATING RANGE DIAGRAM G X4/2 - G X5/2 [mbar] 10 9 8 7 6 5 4 3 2 G X4/2 G X5/2 1 0 -1 80 120 160 200 240 280 320 360 400 [kW] Fig. 3 X = Thermal power Y = Pression in the combustion chamber The firing rates has been obtained based on test boilers in accordance with EN267 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non-compliance, contact the manufacturer. G X4/2 - G X5/2 LIGHT-OIL BURNERS TWO STAGE SK070065_B_en DIMENSIONS [MM] Fig. 4 Dimensions G X4/2 - G X5/2 MODEL A B C D E F G H I G X4/2 182 192 318 124 306 248 17 200 200 G X5/2 210 218 400 130 461 310 18 200 200 * See "flame tube length" BOILER PLATE * Suggested dimension of connection between burner and generator. Fig. 5 Boiler plate MODEL L min L* L max M N min N* N max G X4/2 mm 170 205 226 M10 130 140 160 G X5/2 mm 205 220 226 M10 140 150 180 FLAME TUBE LENGTH Flame tube length must be selected based on the specifications supplied by boiler manufacturer and, in any case, it must be greater than the thickness of the boiler door included its insulation. In case of boilers with flame inversion or front flue combustion chambers, it is necessary to insulate the area between the flame tube and front door with refractory material. This protection material must not impede flame tube extraction. MODEL TC TL ** G X4/2 mm 130 250 G X5/2 mm 215 335 ** For different flame lengths, please contact our Technical-Sales Department. G X4/2 - G X5/2 LIGHT-OIL BURNERS TWO STAGE SK070065_B_en PRODUCT SPECIFICATION SHORT DESCRIPTION Light-oil burners two stage. DETAILED SPECIFICATION Light-oil burner two stage composed by: • Aluminium frame; • Combustion head with micro adjustment at high efficiency and high flame stability; • Protection cover with noise reduction plate; • Flange and insulating gasket for fixing at boiler; • Single-phase power supply; • Photoresistance for flame detection; • IP 40 electric protection level; • Hydraulic system of regulation combustive air on the two stages of flame. CONFORMING TO: • CE rules; • 2014/30/UE Directive E.M.C.; • 2014/35/UE Directive L.V.; • 2014/68/EU Directive M.D.; • 97/23/CE Directive P.E.D.; • Reference rules: EN267 (liquid fuel) - EN746-2 (industrial thermoprocessing equipment). STANDARD EQUIPMENT • Flexible hoses for connection; • Line filter; • Isomart gasket; • Nozzles; • Flange with insulating gasket; • Burner nameplate; • Warranty; • Instruction handbook for installation, use and maintenance. The illustrations and data here shown are indicative. F.B.R. Bruciatori S.r.l. reserves the right to bring, without any obligation of warning, any changes that would be appropriate to the continuing development of their products. G X4/2 - G X5/2
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

FBR Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

Pembakar industri diesel FBR X G X4/2 TL SI adalah pembakar dua tahap (two stage) berbahan bakar minyak ringan (light oil) yang dirancang untuk aplikasi ketel uap dan peralatan pembakaran industri. Dengan daya termal maksimum 296 kW dan aliran bahan bakar 25 kg/jam, unit ini dilengkapi dua nosel, rangka aluminium, serta penutup pelindung dengan peredam kebisingan. Spesifikasi teknisnya meliputi motor kipas 250 W, proteksi IP 40, dan suplai listrik 1N~230V — cocok untuk kebutuhan pembakar industri di Indonesia.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Apa spesifikasi teknis FBR X G X4/2 TL SI?

Pembakar industri FBR X G X4/2 TL SI memiliki daya termal maksimum 296 kW (94,9 kW minimum), aliran bahan bakar 25 kg/jam (maksimum) dan 8 kg/jam (minimum), motor kipas 250 W, proteksi IP 40, serta suplai listrik 1N~230V. Berat unit 15,5 kg dan tingkat kebisingan 68-69 dB(A).

Untuk apa FBR X G X4/2 TL SI digunakan?

Pembakar industri FBR X G X4/2 TL SI digunakan pada ketel uap dan peralatan pembakaran industri yang memerlukan pembakaran dua tahap (two stage) dengan bahan bakar minyak ringan. Cocok untuk aplikasi pemanasan industri, proses produksi, dan sistem pembakaran lainnya yang membutuhkan efisiensi tinggi dan stabilitas nyala api.

Bagaimana cara memilih FBR X G X4/2 TL SI yang tepat?

Pilih FBR X G X4/2 TL SI jika kebutuhan daya termal Anda berada dalam rentang 94,9 kW hingga 296 kW dan aliran bahan bakar antara 8 kg/jam hingga 25 kg/jam. Pastikan suplai listrik 1N~230V tersedia dan suhu udara pembakaran maksimum 60°C. Unit ini cocok untuk operasi intermiten (minimal 1 stop setiap 24 jam).

Di mana beli FBR X G X4/2 TL SI di Indonesia?

Anda dapat membeli FBR X G X4/2 TL SI melalui 3G Electric, distributor resmi yang memasok dan mengirimkan peralatan industri ini ke seluruh Indonesia. Kami menangani logistik dan bea cukai sehingga Anda dapat menerima produk dengan mudah. Hubungi kami untuk minta penawaran.

Digunakan dalam

Aplikasi umum untuk FBR
Hospitality and commercial HVAC — cast-iron boiler plants in hotels and shopping complexes
Pharmaceutical and biotech process heat — gas-fired burners with ATEX gas trains for classified-zone requirements
Medical-waste and bio-hazard incineration — FGP progressive dual-fuel systems
Food and beverage steam boilers — single-stage G-series for continuous-duty cycles
Marine and offshore platforms — IP54-rated X-series for high-humidity marine operations

FBR Produk

3G Electric memasok FBR burners & combustion. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Rangkaian Gas & Katup Gas Transformator Pengapian Kontrol Pembakar Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
G X4/2 TC SI
FBR
G X4/2 TC SI
X G X4 TL S
FBR
X G X4 TL S
X G X4S TL S
FBR
X G X4S TL S
X G X4H TL c
FBR
X G X4H TL c
X G X4 TC S
FBR
X G X4 TC S
G X5/2 TL SI
FBR
G X5/2 TL SI

Lainnya dari FBR

Lihat semua FBR suku cadang
FBR
FBR
K 350/M TL
FBR
FBR
G 0S LX TC
FBR
FBR
G X5 F TL
FBR
FBR
G X4.22 LX TL
FBR
FBR
K X6/M EL EVO TL
FGP 1500/M TL MEC
FBR
FGP 1500/M TL MEC
FGP 75/2 LX TC
FBR
FGP 75/2 LX TC
FBR
FBR
K 250/M TL EL