FBR X G X5.22 TL SI

Pembakar diesel FBR X G X5.22 TL SI adalah pembakar industri dua langkah tekanan (two steps pressure) seri Low NOx yang dirancang untuk bahan bakar minyak ringan (light oil) dengan emisi NOx rendah (< 120 mg/kWh)…

SKU 3G-FBR-00045

Merek
FBR
Item
X G X5.22 TL SI
Kategori
Burners & Combustion
UNSPSC
40101834 — Burners
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Distributor Resmi
Langsung dari OEM
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

FBR
Weight
52 kg
stage
Serie low nox
fuel type
Light oil
nozzle mm
215
fan motor w
0.74
power kw max
391.4
power kw min
166
flow kg h max
33
flow kg h min
14
ip protection
IP 40
noisiness dba
77
electrical supply
1
power supply info
3~400V, 1N~230V 50Hz
current absorption a
2
thermal power mcal h
147/204-450
nominal electric power w
1.1
max combustion air temp c
60

Konten Lembar Data

LIGHT-OIL BURNERS AT TWO STEPS PRESSURE SK070045_A_en LIGHT-OIL BURNERS AT TWO STEPS PRESSURE G X3.22 - G X4.22 - G X5.22 Light-oil burners at two steps pressure. They are composed by: aluminium frame, protection cover with noise reduction plate, combustion head with micrometric adjustment, high flame stability. Compact overall dimensions and disposition rationalized of the components with accessibility facilitated for the operations of setting and maintenance. Complete of connector 7 poles, flange and gasket for installation on boiler, nozzle, flexible pipes, line filter. Fig. 1 G X3.22 Fig. 2 G X4.22 G X3.22 - G X4.22 - G X5.22 LIGHT-OIL BURNERS AT TWO STEPS PRESSURE SK070045_A_en TECHNICAL DATA G X3.22 - G X4.22 - G X5.22 MODEL G X3.22 G X4.22 G X5.22 Flow min. 1st st. / min. 2nd st. - max. 2nd st. * [kg/h] 4.8/7-15 6.8/10-20 9/12-30 Thermal power min. 1st st. / min. 2nd st. - max. 2nd st. * [Mcal/h] 49/71-153 69/102-204 92/122-306 Thermal power min. 1st st. / min. 2nd st. - max. 2nd st. * [kW] 57/83-178 80/118-236 107/142-355 Fuel: LIGHT-OIL 1.5°E at 20°C = 6.2 cSt = 35 sec Redwood N°1 Intermitted working operation (min. 1 stop every 24 hours) two steps pressure Environmental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max. temperature combustion air [°C] 60 Nominal electric power [W] 220 250 600 Fan motor [W] 150 200 450 Nominal current absorption [A] 1 1.1 2.7 Power supply: 1N~230V - 50Hz Electric protection degree: IP 40 Noisiness min. - max. ** [dBA] 66-66 67-68 71-72 Burner weight *** [kg] 14 14 25 * Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** Measured sonorous pressure in the combustion laboratory, with burner on operation on beta boiler to 1m of distance (UNI EN ISO 3746). *** For burner with iron cover (F) add 3 kg to the weight. OPERATING RANGE DIAGRAM G X3.22 - G X4.22 - G X5.22 Fig. 3 X = Thermal power Y = Pression in the combustion chamber The firing rates has been obtained based on test boilers in accordance with EN267 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non-compliance, contact the manufacturer. G X3.22 - G X4.22 - G X5.22 LIGHT-OIL BURNERS AT TWO STEPS PRESSURE SK070045_A_en DIMENSIONS [MM] Fig. 4 Dimensions G X3.22 - G X4.22 - G X5.22 MODEL A B C D E F G H I G X3.22 182 192 318 110 306 248 17 200 200 G X4.22 182 192 318 124 306 248 17 200 200 G X5.22 210 218 400 130 461 310 18 200 200 * See "flame tube length" BOILER PLATE ** Suggested dimension of connection between burner and generator. Fig. 5 Boiler plate MODEL L min L ** L max M N min N ** N max G X3.22 mm 160 170 226 M10 120 130 140 G X4.22 mm 170 205 226 M10 130 140 160 G X5.22 mm 205 220 226 M10 140 150 180 FLAME TUBE LENGTH Flame tube length must be selected based on the specifications supplied by boiler manufacturer and, in any case, it must be greater than the thickness of the boiler door included its insulation. In case of boilers with flame inversion or front flue combustion chambers, it is necessary to insulate the area between the flame tube and front door with refractory material. This protection material must not impede flame tube extraction. MODEL TC TL *** G X3.22 mm 130 250 G X4.22 mm 130 250 G X5.22 mm 215 335 *** For different flame lengths, please contact our Technical-Sales Department. G X3.22 - G X4.22 - G X5.22 LIGHT-OIL BURNERS AT TWO STEPS PRESSURE SK070045_A_en PRODUCT SPECIFICATION SHORT DESCRIPTION Light-oil burners at two steps pressure. DETAILED SPECIFICATION Light-oil burners at two steps pressure, composed by: • Aluminium frame; • Combustion head with micrometric adjustment, high flame stability and low emissions; • Protection cover with noise reduction plate; • Flange and insulating gasket for fixing at boiler; • Single-phase power supply; • Photoresistance for flame detection; • IP 40 electric protection level; • Hydraulic system of regulation combustive air on the two stages of flame. CONFORMING TO: • CE rules; • 2014/30/UE Directive E.M.C.; • 2014/35/UE Directive L.V.; • 2014/68/EU Directive M.D.; • 97/23/CE Directive P.E.D.; • Reference rules: EN267 (liquid fuel) - EN746-2 (industrial thermoprocessing equipment). STANDARD EQUIPMENT • 7-poles plug for the electrical connections; • Flexible hoses for connection; • Line filter; • Isomart gasket; • Nozzle; • Flange with insulating gasket; • Burner nameplate; • Warranty; • Instruction handbook for installation, use and maintenance. The illustrations and data here shown are indicative. F.B.R. Bruciatori S.r.l. reserves the right to bring, without any obligation of warning, any changes that would be appropriate to the continuing development of their products. G X3.22 - G X4.22 - G X5.22
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

FBR Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

Pembakar diesel FBR X G X5.22 TL SI adalah pembakar industri dua langkah tekanan (two steps pressure) seri Low NOx yang dirancang untuk bahan bakar minyak ringan (light oil) dengan emisi NOx rendah (< 120 mg/kWh). Model ini memiliki rentang daya termal 166–391,4 kW, laju aliran bahan bakar 14–33 kg/jam, dan konsumsi arus nominal 2 A pada suplai listrik 3~400V atau 1N~230V 50Hz. Dilengkapi dengan rumah aluminium, penutup pelindung dengan peredam kebisingan (77 dBA), serta kepala pembakaran dengan penyesuaian mikrometrik untuk stabilitas nyala api tinggi, produk ini cocok untuk aplikasi ketel uap industri di Indonesia.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Apa spesifikasi teknis FBR X G X5.22 TL SI?

Pembakar diesel FBR X G X5.22 TL SI memiliki daya termal 166–391,4 kW, laju aliran bahan bakar 14–33 kg/jam, konsumsi arus 2 A, dan suplai listrik 3~400V atau 1N~230V 50Hz. Berat bersih 52 kg, tingkat perlindungan IP 40, dan tingkat kebisingan 77 dBA. Suhu udara pembakaran maksimal 60°C.

Untuk apa FBR X G X5.22 TL SI digunakan?

Pembakar ini digunakan untuk aplikasi pembakaran pada ketel uap (boiler) industri dengan bahan bakar minyak ringan (light oil). Sistem dua langkah tekanan (two steps pressure) dan teknologi Low NOx membuatnya cocok untuk industri yang memerlukan emisi rendah (< 120 mg/kWh) dan efisiensi pembakaran tinggi.

Apa perbedaan FBR X G X5.22 TL SI dengan model G X3.22 dan G X4.22?

FBR X G X5.22 TL SI memiliki kapasitas lebih besar dibanding G X3.22 dan G X4.22. Daya termal maksimal 391,4 kW, laju aliran bahan bakar hingga 33 kg/jam, dan konsumsi arus 2 A. Model G X3.22 maksimal 178 kW dan G X4.22 maksimal 236 kW. Berat G X5.22 adalah 52 kg, lebih berat dari model lainnya.

Di mana beli FBR X G X5.22 TL SI di Indonesia?

Anda dapat membeli FBR X G X5.22 TL SI melalui 3G Electric, distributor resmi yang memasok dan mengirimkan peralatan industri ini ke seluruh Indonesia. Kami menangani logistik dan kepabeanan untuk memastikan produk sampai ke lokasi Anda dengan aman. Hubungi kami untuk minta penawaran.

Bagaimana cara memilih pembakar diesel FBR yang tepat?

Pilih model berdasarkan kebutuhan daya termal dan laju aliran bahan bakar. FBR X G X5.22 TL SI cocok untuk aplikasi dengan daya 166–391,4 kW dan laju aliran 14–33 kg/jam. Pastikan suplai listrik sesuai (3~400V atau 1N~230V 50Hz) dan perhatikan tingkat kebisingan 77 dBA serta suhu udara pembakaran maksimal 60°C.

Digunakan dalam

Aplikasi umum untuk FBR
Hospitality and commercial HVAC — cast-iron boiler plants in hotels and shopping complexes
Pharmaceutical and biotech process heat — gas-fired burners with ATEX gas trains for classified-zone requirements
Medical-waste and bio-hazard incineration — FGP progressive dual-fuel systems
Food and beverage steam boilers — single-stage G-series for continuous-duty cycles
Marine and offshore platforms — IP54-rated X-series for high-humidity marine operations

FBR Produk

3G Electric memasok FBR burners & combustion. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Rangkaian Gas & Katup Gas Transformator Pengapian Kontrol Pembakar Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
X G X5.22 TC SI
FBR
X G X5.22 TC SI
G X5/2 TL SI
FBR
G X5/2 TL SI
X G X3.22 TL SI
FBR
X G X3.22 TL SI
G X5/2 TC SI
FBR
G X5/2 TC SI
X G X5S TL S
FBR
X G X5S TL S
G X5 TL S
FBR
G X5 TL S

Lainnya dari FBR

Lihat semua FBR suku cadang
FBR
FBR
K 350/M TL
FBR
FBR
G 0S LX TC
FBR
FBR
G X5 F TL
FBR
FBR
G X4.22 LX TL
FBR
FBR
K X6/M EL EVO TL
FGP 1500/M TL MEC
FBR
FGP 1500/M TL MEC
FGP 75/2 LX TC
FBR
FGP 75/2 LX TC
FBR
FBR
K 250/M TL EL